STANDARD MODELS & ADDITIONAL PARTS HEALTH & SAFETY PRECAUTIONS This section describes some of the potential risks and the ways in which they can be reduced. These guidelines do not set out or interpret the law – they are simply a guide to improve safety during the plant’s lifecycle. The Principal Contractor and service companies should produce their own comprehensive health and safety plan.
Page 5
Civil Installation: Installation should only be carried out by qualified and experienced professionals who understand sewage and drainage systems and their obligations under the Health and Safety at Work Act, Construction Design Management (CDM) Regulations and the Environmental Protection Act. Where necessary they should seek advice from a civil engineer.
Page 6
Delivery to site: If there are overhead electrical cables, ensure that there is adequate clearance or that the power is turned off. If there are any obstructions to site delivery, please contact WPL to advise in advance. Installer must carry out a detailed Lift Plan prior to commencing work.
Page 7
Tank cover: Do not leave the plant cover open for any longer than is strictly necessary. Temporary barriers and warning signs should be erected around any open covers or manways as appropriate. Blower kiosk Do not allow surface water to form a pool around –...
STANDARD MODELS Standard tank models DMS2, DMS3, DMS4 and DMS5 come supplied with: • Tank as specified x1 • Tank lid with M10 x 50mm stainless steel hex bolts x2 • Weatherproof kiosk x1, comes with a low air pressure alarm beacon and blower inside •...
ADDITIONAL PARTS Depending on site conditions, DMS and DMC models may be supplied with an invert extension and or external pumping chamber (EPC). Please specify on order if you require any additional factory-fitted parts such as invert extensions and external pumping chambers. INVERT EXTENSIONS DMS Invert Extensions: Standard factory-fitted body invert extension heights of 700mm or 1000mm.
External pumping chamber (EPC) If a deeper factory-fitted invert extension is required, please specify on order. The EPC also has the added benefit of being used as a sample chamber. The EPC comes supplied with: • Pumping chamber x1 • Manhole cover x1 •...
NON-FACTORY FITTED INVERTS DMS non-factory fitted neck invert extension: When on site and a deeper invert is required, you can order a 460mm invert neck extension which can be cut down to the required height. Only one 460mm extension can be fitted to the tank - do not stack with an additional neck invert extension.
DMS AND DMC - EPC non-factory fitted neck invert extension ring: When on site and a deeper EPC invert is required - 215mm x 2 extension rings are available to order. This is to accompany a non-factory fitted 460mm DMS neck extension.
WHAT IS WASTEWATER TREATMENT? Wastewater treatment, also known as sewage treatment, is the process of removing contaminants and suspended solids from primarily household and commercial property waste such as toilets, showers and sinks. WPL DIAMOND RANGE? The WPL Diamond compact package wastewater (sewage) treatment plant is suitable for domestic and small commercial properties in all ground conditions where mains drainage is unavailable.
HOW THE WPL DIAMOND WORKS Unlike the traditional septic tanks, this modern packaged wastewater treatment plant is designed with an aerated process for todays’ increased volume of water usage in everyday life. The wastewater flows into the main tank and enters directly into the bio-chamber.
SIZING OF THE PLANT CONSIDERATIONS Water softeners Salt based water softeners can significantly reduce bacteria growth in the treatment plant and negatively affect its performance. An existing softener can be used but regeneration should be minimised and the quality of discharge monitored. A non- salt based softener should be used where possible.
The WPL Diamond range is based on a population equivalent. However please ensure that the plant been sized to suit requirements using the current British Water Flows and Loads codes of practise. DMS range Inlet Height Height to Height/In Weight Total Model Population...
Planning Please ensure all necessary permissions have been sought and granted and ensure that due consideration/ appropriate action has been given/ taken regarding the following: • Planning Permission, Building Regulations, and other regulating or interested parties • Environment Agency, SEPA or Natural Resources Wales requirements •...
Delivery to site Off-loading will only take place at the nearest hard standing to site that is suitable for heavy goods vehicles. If damage is identified on delivery, WPL must be notified within 24 hours. If the nearest road access for a heavy goods vehicle is not adjacent to the site, it is the responsibility of the contractor/purchaser to arrange transport from the road to the site.
WPL Diamond plant location The WPL Diamond plant must be sited: • Within 30 metres of heavy vehicle access for de-sludging • As far from the habitable parts of the dwelling as possible. Many local authorities recommend allowing a minimum of 7 metres, but easements are possible for smaller sites subject to local planning approval.
Blower kiosk • Ideally located 5-10m from the tank • Ensure beacons are visible – this will aid prompt detection of operational failures • Choose a shaded northerly aspect with easy access for maintenance. Avoid direct sunlight, vegetation/plant overgrowth, dust and flood water •...
TANK INSTALLATION Excavating the correct size trench 300mm 300mm ALLOW DEPTH FOR INVERT EXTENSIONS DMS MODELS - 300mm DMC MODELS - 450mm A square stepped excavation may be used due to the physical shape of the WPL Diamond plant. Allow adequate clearance for all pipes and any other connections to the unit.
Excavation guide WATER FROM HOSE 750mm DMS MODELS 300mm DMC MODELS 450mm STEP 1 STEP 2 MAKE SURE THE DIAMOND BASE IS INSTALLED READY. ENSURE THE DIAMOND IS LEVEL. FOR THE DIAMOND TANK TO BE LOWERED ON TO. ADD WATER INTO THE TANK AT THE SAME TIME WHEN. NOTE:- THE BASE CAN BE SEMI DRY CONCRETE TO.
INVERT EXTENSIONS Please ensure trench excavation takes into account invert requirements. DMS body invert extensions The standard factory-fitted body invert extension height is either 700mm or 1000mm. 700MM (1000MM) BODY EXTENSION FACTORY FITTED Non-factory fitted DMS 460mm body invert extension installation instructions 1.
PLAN VIEW Only one 460mm extension can be fitted to a WPL Diamond tank, do not stack with an additional body invert extension. 76mm CUT LINE FOR 105mm EXTENSION CUT LINE FOR 190mm EXTENSION CUT LINE FOR 290mm EXTENSION CUT LINE FOR 370mm EXTENSION LEAVE BODY UNCUT FOR 460mm EXTENSION SIDE VIEW Illustration of increments to where the 460mm neck invert can be cut to meet the required height.
BLOWER KIOSK INSTALLATION Each WPL Diamond comes with its own weatherproof kiosk, complete with an air blower, low air pressure alarm beacon, 10m of hose and two (2) hose clips. Make sure the air blower is installed in a dry, well ventilated area. If it is situated outside, ensure it is installed in the approved, weatherproof housing supplied with the WPL Diamond treatment plant.
Blower motor size (kW) and power Model Population range (persons) Blower motor size (kW)* Total power consumption DMS2 0.080 0.080 DMS3 5-11 0.090 0.090 DMS4 10-15 0.160 0.160 DMS5 14-20 0.230 0.230 DMC6 21-27 0.550 0.550 DMC7 28-35 0.750 0.750 DMC8 36-45 0.750...
DMS kiosk The DMS kiosk is designed to be partially submerged in the ground (to a depth of 200mm), although it can be mounted above ground if the owner prefers. • Dig a hole approximately 100mm wider than the kiosk dimensions and approximately 200mm deep •...
Connecting tank (DMS/DMC) to the kiosk • Dig a narrow trench to a depth of approx. 500mm, from the tank to the site of the blower kiosk and lay the hose duct in it • Lay ducting from the kiosk to the mains power supply •...
Sample chamber installation The sample chamber routes all outgoing flow (treated effluent) from the tank. There is a drop within the chamber to ease obtaining a sample, accessible from the 250mm removable inspection hatch. The sample chamber should be: • Positioned no further than 5m away from the outlet of the tank •...
OPERATION & MAINTENANCE Authorised service kits and spare parts are supplied by WPL. Service and maintenance advice is available from WPL. All service and maintenance for the WPL Diamond plant must be recorded in the logbook provided. OPERATION It is important that the sewage input conditions are kept within the plant design criteria, including the population equivalent (British Water Flows and Loads practises).
Procedure for de-sludging De-sludging must be carried out by an approved sewage treatment tanker company. Approximate de-sludge volumes guide Model App. De-sludge Volumes (litres) The amount of sludge DMS2 1500 accumulated depends DMS3 2100 on the loading of the DMS4 2650 plant.
TROUBLESHOOTING DMC & DMS RANGE A - SYMPTOM B - CAUSE C - REMEDY 1. Air blower is running 1. Blocked air diffuser 1. Disconnect air pipe at the but little or no turbulence union and clean or replace is observed in aeration air diffuser chamber 2.
Page 35
A - SYMPTOM B - CAUSE C - REMEDY 7. Aeration chamber contents 11. System is lightly loaded 12. Continue start-up regime have a grey appearance and and has been in use for of minimal laundry and slightly septic odour less than 3 months minimal cleaning chemicals.
EXTERNAL PUMPING CHAMBER DMS-EPC MODELS The DMS EPC is factory-fitted; please ensure you order with the WPL Diamond plant. The EPC has been developed to provide a means of delivery for treated effluent where the existing terrain and invert levels of the pipework prevent normal gravitational discharge.
INSTALLATION CONSIDERATIONS • Excavate a hole 600mm in diameter and 1550mm deep • When deeper invert levels are required, chamber extensions are available on request • Level the base of the trench with concrete (not supplied), roughly 50mm deep • Carefully lower the chamber into the hole, drop the straps on the outside of the chamber and insert the tank outlet pipe into the chamber inlet hole •...
ELECTRICAL INSTALLATION • Electrical connection should be made via its own dedicated supply • Install a suitable conduit/pipe to carry all wires from the kiosk and high- level alarm float switch • Run a draw line through the conduit/pipe • Tie the draw line to the cables and pull the cables through the fittings, into the conduit/pipe and through to the blower kiosk •...
Float switch: • Fill the chamber with clean water, until the float switch is fully covered • Turn the isolator to the on position • Check operation of the pump, ensuring that the level in the chamber drops until the float switch stops the pump •...
MAINTENANCE For DMC-EPC models, please ensure the operation and cleanliness of the external pumping chamber is checked during servicing. All servicing and maintenance must be recorded in the accompanying logbook. Before undertaking any maintenance disconnect the pump from the power supply (i.e.
TROUBLESHOOTING DMS-EPC (models with an external pumping chamber) FAULT CHECK (POSSIBLE CAUSE) REMEDY A. Check that there is power to pump. A. Check that there is power to pump. B. If fuses are burnt-out, change Pump does not start B. Check the protection fuses. them.
HINTS & TIPS It is important that your family, guests and visitors are made aware that your house is connected to a specialist, biological sewage treatment system. They need to know that they should not put anything down the toilet, sinks or drains which could harm the bacteria or block the system.
Page 43
Don’t – non-biodegradable products: • Don’t put sanitary towels, tampons, disposable nappies, baby wipes, cotton wool, incontinence pads, cotton buds, rubber products or other non-biodegradable products down the toilet Don’t – Kitchen: • Don’t pour fat, grease or cooking oil down the sink or drains Don’t –...
PROCESS GUARANTEE AND WARRANTY Process guarantee The Process is guaranteed to meet the designed effluent discharge standard for the life of the plant provided that: • All aspects of the installation manual and user guide operation and maintenance manual are adhered to •...
Warranty limitations/exemptions WPL shall not be liable for any labour involved for the removal or replacement of its equipment or the subsequent transportation, handling or packaging of any part or parts thereof. In no case will WPL be liable for loss incurred because of the interruption of service or for consequential damages, labour or expense required to repair defective units, nor shall this constitute a cause for the cancellation of the contract of purchase and sale.
Page 46
WPL Diamond range is subject to our standard terms and conditions which are available on request. WPL is a trading name of WCS Environmental Engineering Ltd which is a portfolio company of Marlow PLC.