  • Page 2: Important: Please Read And Follow

    IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning, please read these instructions completely and carefully. 2. Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty. 3. Please observe all local and national codes and ordinances. 4.
  • Page 3: Basic Specifications

    BASIC SPECIFICATIONS DESCRIPTION VGSU103 (30” W.) Cutout Width - Minimum 26 7/8” (68.3 cm) Maximum 29 7/8” (75.9 cm) Cutout Height - Minimum Cutout Depth - Minimum Maximum Overall Width 30 3/4” (78.1 cm) Overall Height from Bottom Overall Depth from Rear Gas Requirements To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically changed.
  • Page 4: General Information

    DESCRIPTION Cutout Width - Minimum Maximum Cutout Height - Minimum Cutout Depth - Minimum Maximum Overall Width Overall Height from Bottom Overall Depth from Rear Gas Requirements Electrical Requirements Maximum Amp Usage Surface Burner Rating Left Front- 14,000 Nat./13,500 LP (BTU) Left Rear- 12,000 Nat./11,500 LP (BTU) Center Front/Rear...
  • Page 5 PROXIMITY TO SIDE CABINETS 1. The cooktop may be installed directly to existing base cabinets. 2. The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 8” (20.3 cm) side clearance from the cooktop to such combustible surfaces above the 36”...
  • Page 6 WOOD/COMPOSITE OVERLAY INSTALLATION The bottom of the hood should be 30” (76.2 cm) min. to 36” (91.4 cm) above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the rangehood installation instructions for further information.
  • Page 7 CUTOUT DIMENSIONS FOR VGSU AND DOWNDRAFT VGSU Burner Box Dimensions 30” W. Model 26 11/16” (67.8 cm) 18 1/2” (46.2 cm) 3 1/4” (8.3 cm) 36” W. Model 18 1/2” (46.2 cm) 2 3/4” (7.0 cm) For Use with Downdraft Models 33 3/16”...
  • Page 8 VGSU Height Dimension 5” (12.7 cm) 2 1/2” (6.4 cm) 30” W. VGSU Top Dimensions NOTE: Narrow edge of grate goes toward center of unit 36” W. VGSU Top Dimensions NOTE: Narrow edge of grate goes toward center of unit 6 19/32”...
  • Page 9 DIMENSIONS FOR INSTALLATION OF VGSU OVER SINGLE ELECTRIC OVEN 26 7/8” 3” (73.3 cm) (7.6 cm) min. 18 1/2” VGSU103 (47.0 cm) 30” min. cutout 14 5/8” 12 1/4” (37.2 cm) (31.1 cm) 14 1/4” 14 1/4” (36.2 cm) (36.2 cm) 28 1/8”...
  • Page 10 DGCU CUTOUT DIMENSIONS Cutout Opening DGCU Burner Box Dimensions 19 11/16” (50.0 cm) DGCU Height Dimension 5 3/8” (13.7 cm) 19 3/4” (50.2 cm) 30” W. 36” W. 45” W. Electric Cord 48” (121.9 cm) 30” W. Model 28 3/4” (73.0 cm) 36”...
  • Page 11 30” W. DGCU Top Dimensions 21“ (53.3 cm) 30 3/4” (78.1 cm) 36” W. DGCU Top Dimensions 21“ (53.3 cm) 36 3/4” (93.4 cm) 45” W. DGCU Top Dimensions 21“ (53.3 cm) 45” (114.3 cm)
  • Page 12 DGSU CUTOUT DIMENSIONS Cutout Opening DGSU BURNER BOX DIMENSIONS 19 3/4” (50.2 cm) 30” W. 36” W. Electric Cord 48” (121.9 cm) 30” W. Model 29 1/8” (74.0 cm) 36” W. Model 34 7/8” (88.6 cm) 19 3/4” (50.2 cm) Minimum 20 1/8”...
  • Page 13 30” W. DGSU TOP AND HEIGHT DIMENSIONS 21“ (53.3 cm) 30 3/4” (78.1 cm) 36” W. DGSU TOP AND HEIGHT DIMENSIONS 21“ (53.3 cm) 3 1/8” (7.9 cm) 36 3/4” (93.4 cm) 3 1/8” (7.9 cm) 4 3/8” (13.7 cm) 1 3/4”...
  • Page 14 INSTALLATION OF HOLD DOWN BRACKET FOR DGCU AND DGSU MODELS Two (2) hold brackets will be provided with the DGSU models and (4) hold brackets will be provided with the DGCU models. After cooktop has been installed into the countertop, locate the brackets in the slots as needed (Figure 1).
  • Page 15: Gas Connection

    GAS CONNECTION The gas supply (service) line must be the same size or greater than the inlet line of the appliance. All cooktops use a 1/2” (1.3 cm) I.D. NPT (Sch40) inlet. Sealant on all pipe joints must be resistive to LP/Propane gas. 1.
  • Page 16: Electrical Connection

    Scratches are almost impossible to remove. REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the range. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a...