Advertisement

Quick Links

Activ Aqua Bed
Manual guide
vacuactiv.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Activ Aqua Bed and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VACU ACTIV Activ Aqua Bed

  • Page 1 Activ Aqua Bed Manual guide vacuactiv.com...
  • Page 2 +48 059 843 43 43 World Wide +48 660 216 370 E-mail contact@vacuactiv.com Customer service / Technical www.vacuactiv.com/techni- service (ordering spare parts cal-support/ for machine components): E-mail support@vacuactiv.com Phone +48 501 186 938 www.vacuactiv.com TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 3: Table Of Contents

    7.3 Setting water temperature 7.4 Selecting a programme 7.4.1 Setting patient height 7.4.2 Massage types 7.4.3 Selecting body parts 7.4.4 Setting the appliance’s runtime 7.4.5 Starting a programme 7.4.6 Pausing the program Notes Contact TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 4: Safety & Warning

    Synchronisation – the state of the appliance used to calibrate the appliance’s sensors and motors. While in this state, the appliance verifies the correct functioning of the component control systems. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 5: Transport And Installation Of The Appliance

    In addition, the appliance has a bathtub level sensor. When the bathtub is filled, a relevant message is displayed on the touchscreen. Therapy should be carried out by trained specialised personnel. The product is not intended for home use. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 6: Electrical Specifications Of The Appliance

    Current drawn by the water pumps 1 1.7 A Nozzle travel motor power supply 24 V DC Nozzle travel motors output 50 W Nozzle travel motor current Securing the installation RCD 16 Amp type B or C TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 7: Connecting A Touchscreen

    Then, turn the locking knob 90 degrees to lock the screen and protect it from damage. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 8: Filling The Appliance With Water And Draining It

    Upon connecting the water hose from the water mains, turn the drain valve from the closed position to the open position. The procedure for filling the appliance with and draining it is outlined below. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 9 STEP 1 Loosen the oxygen therapy cover. To do this, use an Allen key. STEP 2 Loosen the screws securing the housing to the appliance frame. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 10 Loosen the fixing screws from the front of the appliance. Use an Allen key. STEP 4 Carefully lift the appliance housing and pull it away from the frame. Disconnect the LED supply connectors and the communication leads for the touchscreen. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 11 STEP 5 Remove the black cover and turn the vent plug. Once it is loosened, press the valve stem and turn it by 90 degrees in a gentle motion. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 12 The water should be changed at least once a month when the appliance is in use. Add glycol or other agents that prevent the build-up of scale and algae, which can damage the appliance, to the water. The use demineralised water is acceptable. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 13: Oxygen Generator

    The generator is ready for operation. In order for the generator to start working, press the “Done” button on the touch screen. Other options are not available in this hydromassage version. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 14: Connecting The Oxygen Generator To The Hydromassage

    The icon on the generator’s dashboard will flash. Once the phone is connected, the LED will light up solid. This means that the phone is connected and ready for use. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 15: Controlling The Led Light

    6.5 Adjusting the oxygen delivery rate Blowing power is adjusted by turning the right-hand dial. Turning it to the left will increase the flow of oxygen, while turning it to the right will decrease the flow. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 16: Setting The Time

    6.6 Setting the time It is possible to set the generator’s running time. The appliance’s running time can be changed by pressing the key with the clock symbol on the dashboard. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 17: Description Of The Interface

    Temperature and water level icons are shown in the picture below. If they are displayed and the water level can be seen (after having filled the appliance), this means that communication is present. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 18: Switching The Water Heating On And Off

    During any of the massage programmes, the appliance heater is switched off to reduce power consumption. Moreover, the heater will not be switched on when the water level is insufficient. Heating the water to 25 degrees takes two hours. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 19: Setting Water Temperature

    24 to 36 degrees. To set the temperature, turn the dial with your finger to the desired temperature and then confirm. The temperature is adjusted automatically by the controller. When the massage programme is under way, the temperature is not controlled nor is the water heated. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 20: Selecting A Programme

    The height can be specified from 120 cm to 200 cm. To select the desired parameter, swipe the range on the touch screen left or right. Swiping will change the parameter settings. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 21: Setting Patient Height

    Once the height of the person has been adjusted, press the “next” button to go to the next screen. Selecting the proper height causes the programme to adapt to the person and change the appliance’s operating range to make the massage as effective as possible. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 22: Massage Types

    Massage should be coordinated with a qualified professional so that it can be as effective as possible and does not cause patients any pain. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 23: Selecting Body Parts

    You can make your selection by pressing the relevant box with the name of the body part in question. This section allows you to go back to the previous screen to select the type of massage or to move on to specify the massage duration. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 24: Setting The Appliance's Runtime

    “back” button located on the left-hand side of the screen, in the bottom left corner, or you can proceed to the dialogue box in the app to begin training. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 25: Starting A Programme

    Initially, the programme starts with the appliance waiting to be synchronised. Synchronisation takes place whenever the appliance is turned on, but the programme additionally checks whether the appliance is ready to commence training. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 26 To stop the massage, press and hold the “STOP” button for 3 seconds. The appliance will stop operation. Then, the jets will be moved to the initial position. The display will return to home screen. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 27: Pausing The Program

    You can use the “PAUSE” button at any time during a programme. The appliance will stop at this particular moment of the massage. To resume the massage, press the “PAUSE” button again. The appliance will commence operation from the moment it was paused. TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 28: Notes

    Notes TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 29: Contact

    +48 660 216 370 Available at Central European Time 9am - 5pm Monday - Friday Technical support www.vacuactiv.com/technical-support/ support@vacuactiv.com +48 501 186 938 Modrzewiowa 1 Street, 7 6-251 Losino, POLAND Phone +48 59 843 43 43 TECHNICAL SUPPORT Copyright 2023 Vacu Activ www.vacuactiv.com/technical-support/...
  • Page 30 vacuactiv.com...

Table of Contents