40/42-161A User Manual
PXI/PXIe 16 A Power Relay Module
pickeringtest.com
Issue 1.2 August 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40-161A and is the answer not in the manual?

Questions and answers

Summary of Contents for Pickering 40-161A

  • Page 1 40/42-161A User Manual PXI/PXIe 16 A Power Relay Module pickeringtest.com Issue 1.2 August 2023...
  • Page 2 © COPYRIGHT (2023) PICKERING INTERFACES. ALL RIGHTS RESERVED. No part of this publication may be reproduced, transmitted, transcribed, translated or stored in any form, or by any means without the written permission of Pickering Interfaces. Technical details contained within this publication are subject to change without notice.
  • Page 3 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
  • Page 4: Product Safety

    PRODUCT SAFETY LA SÉCURITÉ DES PRODUITS SYMBOLES DE SÉCURITÉ SAFETY SYMBOLS The following safety symbols may be used on the Les symboles de sécurité suivants peuvent être product and throughout the product documentation. utilisés sur le produit et dans l’ensemble de la documentation produit.
  • Page 5: Table Of Contents

    Hardware Installation ............3.1 Software Installation .............3.3 Testing Operation ..............3.4 Section 4 Programming Guide ..............4.1 Programming Options For Pickering PXI/PXIe Modules ...4.1 Module Architecture - SPST Versions .........4.2 Module Architecture - SPDT Versions .........4.3 Programming The Module ............4.4 Section 5 Connector Information ..............5.1 Section 6 Trouble Shooting .................6.1...
  • Page 6 THIS PAGE INTENTIONALLY BLANK PXI/PXIe 16A Power Relay Module 40/42-161A Page (VI)
  • Page 7: Warnings And Cautions

    Blanking panels are signaux d’E/S utilisateur qui peuvent être présents. available to order from Pickering in a variety of slot Les obturateurs sont disponibles sur commande chez widths. If the product is not used in this manner for Pickering dans une variété...
  • Page 8 CAUTION - HANDLING OF ATTENTION - MANIPULATION DES ELECTROSTATIC-SENSITIVE SYMBOL APPAREILS SENSIBLES SEMICONDUCTOR DEVICES ELECTROSTATIQUES Certain semiconductor devices used in Certains appareils semi-conducteurs utilisés this equipment are liable to damage due dans cet équipement sont susceptibles d’être to static voltage. Observe the following endommager en raison de la tension statique.
  • Page 9 3 Year Warranty Hardware Interlock Option The 40-161A (PXI) and 42-161A (PXIe) have a choice of SPST, and SPDT power relay configurations and are suitable for switching loads up to 16 A at 250 VAC. Power relay modules are intended for switching heavy...
  • Page 10: Technical Specification

    6 channels at 16 A) Module Thermal Time Constant: 4 minutes typical For information on module loading & pulsed currents please visit: Pickering’s Wiki page on module current capacity Contact Current, Amps Maximum Standoff Voltage: 400 VDC* 40/42-161A Operations Versus Hot Switch Current Initial On Path Resistance: <20 mΩ...
  • Page 11 3D models for all versions in a variety of popular file Link formats are available on request. No Connection Connectors 40-161A - PXI bus via 32-bit P1/J1 backplane connector. Interlock Connector 42-161A - PXIe bus via XJ3 and XJ4 backplane connectors. Interlock...
  • Page 12 40/42-161A-001/002/003 91-100-092 6 x SPDT 40-161A-102 40/42-161A-101/102 91-100-091 PXI 16 A Power EMR Module With Hardware Interlock For further assistance, please contact your local Pickering 16 x SPST 40-161A-001-HI sales office. 12 x SPST 40-161A-002-HI Interlock Connectors 10 x SPST...
  • Page 13 We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
  • Page 14 16 A Power Relay Module, 40/42-161A Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
  • Page 15: Technical Description

    SECTION 2 - TECHNICAL DESCRIPTION pickering SECTION 2 - TECHNICAL DESCRIPTION FUNCTIONAL DESCRIPTION A functional block diagram is provided in Figure 2.1. The Power Relay Module 40/42-161A is powered by +3.3V and +5V via Compact PCI backplane connector (PXI version) or +3.3V and 12V via PXIe backplane connectors (PXIe versions).
  • Page 16: Hardware Interlock

    SECTION 2 - TECHNICAL DESCRIPTION pickering HARDWARE INTERLOCK The 40/42-161A-xxx-HI modules have an interlock feature that can be used to return the relays (assuming they are fully functional) to their default unpowered state if the interlock connector is not in place or if the connection between the two interlock pins is open-circuit.
  • Page 17 SECTION 2 - TECHNICAL DESCRIPTION pickering +3.3V +3.3V +3.3V Power Power Power Relay Relay Relay Enable Enable Enable Module Module Module With With With Interlock Interlock Interlock Status Status Status PXI Gnd PXI Gnd PXI Gnd To Other Modules With Interlock Figure 2.2 - All 40/42-161A-xxx-HI Modules Enabled by a Common Signal...
  • Page 18 SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK PXI/PXIe 16A Power Relay Module 40/42-161A Page 2.4...
  • Page 19: Installation

    1. Check the module for transport damage and report 1. Vérifiez que le module n’est pas été endommagé any damage immediately to Pickering Interfaces. pendant le transport et signalez immédiatement tout Do not attempt to install the product if any damage dommage à...
  • Page 20 9. For Pickering Interfaces modular LXI installation b. Pour un système comprenant plus d’un châssis, there is no requirement to use any particular power allumez le dernier châssis dans le système up sequence.
  • Page 21: Software Installation

    Si vous n’êtes pas un utilisateur de LabVIEW, vous LabVIEW Runtime Engine installer via the shortcut devez choisir la version “complète”, et une fois qu’elle on the Programs>>Pickering menu. In the absence of a été installée. Lancer le programme d’installation LabVIEW the Runtime Engine is required to support LabVIEW Runtime Engine via le raccourci dans the Pickering Test Panels application.
  • Page 22: Testing Operation

    Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
  • Page 23: Programming Guide

    SECTION 4 - PROGRAMMING GUIDE Programming options for Pickering Interfaces PXI/PXIe Modules For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
  • Page 24: Module Architecture - Spst Versions

    SECTION 4 - PROGRAMMING GUIDE pickering MODULE ARCHITECTURE - SPST VERSIONS The 40/42-161A-001, 40/42-161A-002 and 40/42-161A-003 modules are arrays of 16, 12 or 10 uncommitted SPST relays. In the default state, all signal paths are open. Energising a particular relay closes the contacts and creates a path between the C and A terminals.
  • Page 25: Module Architecture - Spdt Versions

    SECTION 4 - PROGRAMMING GUIDE pickering MODULE ARCHITECTURE - SPDT VERSIONS The 40/42-161A-101 and 40/42-161A-102 modules are arrays of 12 or 6 uncommitted SPDT relays. In the default state, all signal paths are between the C terminal and the corresponding B terminal. Energising a particular relay breaks the C to B connection and creates a path between the C and A terminals.
  • Page 26: Programming The Module

    SECTION 4 - PROGRAMMING GUIDE pickering PROGRAMMING THE MODULE Here are examples of using the drivers with the 40/42-161A-001. Other modules in the range operate in the same way but have different numbers of bits in the sub-unit, see the tables on the previous pages for details.
  • Page 27 SECTION 4 - PROGRAMMING GUIDE pickering Using The Interlock Function The following functions are applicable to 40/42-161A-xxx-HI modules fitted with the optional hardware interlock. Get the status of Interlock Use the attribute “ATTR_INTERLOCK_STATUS”, to the get the status of the interlock.
  • Page 28 SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK PXI/PXIe 16A Power Relay Module 40/42-161A Page 4.6...
  • Page 29 SECTION 5 - CONNECTOR INFORMATION pickering SECTION 5 - CONNECTOR INFORMATION Figure 5.1 - 16 x SPST Power Relay Module 40/42-161A-001: Pinout (20-pin male GMCT connectors viewed from the front of the module) PXI/PXIe 16A Power Relay Module 40/42-161A Page 5.1...
  • Page 30 SECTION 5 - CONNECTOR INFORMATION pickering Figure 5.2 - 12 x SPST Power Relay Module 40/42-161A-002: Pinout (20-pin male GMCT connectors viewed from the front of the module) Figure 5.3 - 10 x SPST Power Relay Module 40/42-161A-003: Pinout (20-pin male GMCT connector viewed from the front of the module) PXI/PXIe 16A Power Relay Module 40/42-161A Page 5.2...
  • Page 31 SECTION 5 - CONNECTOR INFORMATION pickering Figure 5.4 - 12 x SPDT Power Relay Module 40/42-161A-101: Pinout (20-pin male GMCT connectors viewed from the front of the module) Figure 5.5 - 6 x SPDT Power Relay Module 40/42-161A-102: Pinout (20-pin male GMCT connector viewed from the front of the module) PXI/PXIe 16A Power Relay Module 40/42-161A Page 5.3...
  • Page 32 SECTION 5 - CONNECTOR INFORMATION pickering +3.3V (link to pin 2 Ground to allow operation) Status (daisy-chain Enable (link to pin 1 connection to to allow operation) subsequent modules) Figure 5.6 - Pinout: Hardware Interlock Connector Applicable to 40/42-161A-xxx-HI Modules With Hardware Interlock Option...
  • Page 33: Trouble Shooting

    Mises en garde au début du manuel. INSTALLATION PROBLEMS PROBLÈMES D’INSTALLATION The Plug & Play functionality of Pickering switch cards La fonctionnalité Plug & Play des cartes de generally ensures trouble-free installation. commutation Pickering assure généralement une installation sans problème.
  • Page 34 SECTION 6 - TROUBLE SHOOTING SECTION 6 - TROUBLE SHOOTING pickering pickering DIAGNOSTIC UTILITY UTILITAIRE DE DIAGNOSTIC In the “VISA information” section, if VISA is not Dans la section “Informations VISA” si VISA n’est pas installed its absence will be reported. This does not installé...
  • Page 35: Maintenance Information

    Pour les modules PXI qui sont pris en charge dans Pickering Interfaces’ Modular LXI Chassis (such l’un des châssis modulaire LXI de Pickering Interfaces as the 60-102B and 60-103B) no module software (comme le 60-102B et 60-103B) aucune mise à jour update is required.
  • Page 36 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.1 - Power Relay Module 40/42-161A-001 Relay Numbering (16 x SPST) Signal Path Relay Reference on Connections on PCB (with relay energised) A1 to C1 A1, CM1 A2 to C2 A2, CM2 A3 to C3...
  • Page 37 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.3 - Power Relay Module 40/42-161A-003 Relay Numbering (10 x SPST) Signal Path Relay Reference on Connections on PCB (with relay energised) A1 to C1 A1, CM1 A2 to C2 A2, CM2 A3 to C3 A3, CM3 —...
  • Page 38 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.5 - Power Relay Module 40/42-161A-102 Relay Numbering (6 x SPDT) Signal Path Relay Reference on Connections on PCB (with relay energised) — Not Fitted — Not Fitted — Not Fitted — Not Fitted...
  • Page 39: Interlock Connector Wiring

    APPENDIX A - INTERLOCK CONNECTOR WIRING pickering APPENDIX A - INTERLOCK CONNECTOR WIRING The following procedure describes the steps required for the wiring of the interlock connector supplied with versions of the module with the hardware interlock function - all images are courtesy Gigatronix.
  • Page 40 APPENDIX A - INTERLOCK CONNECTOR WIRING pickering Half Shell (A) Braided Screen 4. Fold back braided screen then position the half shells. Note position of orientation lug/slot. Half Shell (B) Trimmed Braided Screen 5. Slide the collet forward trapping the braided screen then trim.

This manual is also suitable for:

42-161a

Table of Contents