When displaying the TARIFF 1 , press and hold the [Set] button for 3 seconds to enter the rate setting.
Press [+] or [-] to select between TARIFF1 and Dual Tariff.
Press the [OK] key to confirm your choice and enter the next setting menu.
If your choice is single rate/tariff,
Press [+] or [-] to select the setting data.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm the current setting.
If your choice is dual rate/tariff,
Press [+] or [-] to select the setting data.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm the current setting and please refer to following example
{Example: Setting Double Rate}
Rate 1: 1.00 $/KWh starting from 8:00;
Rate 2: 0.50 $/KWh Starting from23:00, then:
During 8: 00~23:00 at a unit price of $1/Kwh.
During 23:00~8:00, at a unit price of $0.5/Kwh.
Carbon emission settings
Default value: 0.86 KgCO
/KWh.
2
When the carbon emission unit is displayed, press and hold the [Set] button for 3 seconds to enter the
carbon emission setting.
Press [+] or [-] to select the setting value.
Press the [History] key to switch between digit positions.
Press the [OK] key to save the current settings and exit.
TOTAL
Total carbon emissions
4.Data Reset:
Press the [+] and [-] keys simultaneously for 3 seconds, and the display will flash,
Press the [Set] button again for 3 seconds to reset for factory setting and clear the data.
5.Technical parameters:
5.1 Display Range
Total power consumption time display range: 0 minutes, 0 seconds -9999 days
Power display range:
0.000-9999W
Voltage display range:
0.000-9999V
Current display range:
0.000-9999A
Power data display range:
0.000-9999KWh
5.2 Working conditions:
Working voltage: 230VAC/50HZ
Max current:
16A
Max power:
3680W
5.3 Warning:
For indoor use only and keep out of water!
Do not exceed the max power!
4
User Manual
General Description:
Plug the power meter into a household 230 VAC wall-outlet, and connect with appliances such as
refrigerators, televisions, air conditioners, etc. or connect with microinverter Schuko plug into the
power meter. The power meter displays parameters such as power (watts), electricity consumption
(kilowatt hours), and electricity bill , and can visually display the electricity consumption/generation
for the past 7 days, 7 weeks, and 7 months.
1.Real-Time Display
Press the [Energy] button repeatedly to display in sequence as following:
Power (W): Display real-time power.
AC Voltage(V)
Frequency(Hz)
Current(A)
Power factor: 1.00 means resistive load, < 1 means inductive load.
Maximum power: The maximum instantaneous power of overall
connection.
Maximum current: The maximum instantaneous current of overall
connection.
OVERLOAD
Overload alarm wattage: Defaults to 3680W. When the actual
power exceeds this value, "Overload" flashes.
How to DIY set the Overload alarm wattage?
When the overload alarm wattage is displayed, press and hold the [Energy] button for 3 seconds
to set the overload alarm value.
Press the [+] or [-] keys to adjust the number.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm and exit the settings.
1

Advertisement

loading

Summary of Contents for Offgridtec 8-01-017865

  • Page 1 User Manual When displaying the TARIFF 1 , press and hold the [Set] button for 3 seconds to enter the rate setting. Press [+] or [-] to select between TARIFF1 and Dual Tariff. Press the [OK] key to confirm your choice and enter the next setting menu. General Description: If your choice is single rate/tariff, Press [+] or [-] to select the setting data.
  • Page 2 Warning: For the purpose of safety, the Pre-set overload alarm wattage should be less than 3680W. TOTAL 2.Historical display Press the [History] button repeatedly to display the electricity chart for the past 7 days, past 7 weeks, and past 7 months. Chart is only giving a brief and rough data;...