CHECKING FOR GAS LEAKS

Check that all connections are tight and that the gas
connection has been leak tested before you turn the
appliance on.
Never check for leaks with a flame or pilot light.
Using soapy water coat all connections, if bubbles
appear retighten the cartridge before re-testing.
This appliance must only be serviced by an authorised
person.
Inspect the appliance regularly for signs of wear, leaks
or incorrect operation. If symptoms such as flaring of
the burners, issues with lighting, damages connections
or leaks from seals or gas controls are identified do not
attempt to repair, contact Customer Service on
1300 555 197.
To check if gas remains in the cartridge, disconnect
from the appliance and hold the cartridge in a vertical
position then shake from side to side. If there is a sound
or a feel of liquid movement inside the cartridge, the
cartridge contains gas.
When changing gas cartridge ensure this is conducted
outside in a well ventilated location free from people,
animals and ignition sources such as naked flames, pilot
lights and electrical equipment with heaters or elements.
Check the seals are in place & gas hose is tight before
checking for leaks (if using gas hose to cylinder).
Check that the seals between the appliance and the
gas cartridge are in place and in good condition before
connecting the gas container.
Do not use the appliance if it has damaged or worn
seals.
Do not use this appliance if it is leaking, damaged or
does not operate properly.
4
IMPORTANT
This appliance is designed to be used with a source
water temperature of 20˚C or below, if the temperature
of the outlet water exceeds 50˚C +/- 2˚C the burners
will shut off and will only relight once the outlet water
temperature falls below 45˚C.
This appliance is designed to raise the outlet water
temperature by a maximum (average) of 25˚C to 30˚C
above the source water temperature and can be adjusted
by the gas control. In the event that the temperature lift
is insufficient, simply run water through the appliance
once returning the heated water to the source water
reservoir. Run again through the appliance until the
desired temperature is reached.
During operation ensure that all air inlets and exhausts
are kept free from obstructions and closure.

SAFETY FEATURES

T
his appliance is equipped with the following safety
features:
Over temperature sensor
The appliance will not allow the burner to remain in
operation once the outlet water temperature reaches 50˚C
+/- 2˚C, the burner will automatically relight once the outlet
temperature falls below 45˚C.
Water flow sensor
Water must be flowing through the system to allow the
burner to ignite. In the case that the water supply is
restricted or ceases, ie. the flow switch on shower head is
in the off position, the burner will be extinguished and will
not relight until the water flow recommences.
Tilt switch
In the event that the appliance is moved during operation or
is being operated on an unstable or non-solid surface the
appliance will shut down and must be switched off until a
suitable surface is located.