AlpicAir Comfort Fresh Air 250T Technical Manual

Wall mounted vertical heat recovery ventilator

Advertisement

Quick Links

Wall Mounted Vertical Heat Recovery Ventilator
Technical Manual
Models:
ALPICAIR Comfort Fresh Air 250T
ALPICAIR Comfort Fresh Air 350T
ALPICAIR Comfort Fresh Air 500T
Attention
Please read this manual carefully before using the equipment
Executive Standard:EN13141-7-2010
Contents
1.1 Safety Attentions ·······················································1
1.1.1 Installation·······················································1
1.1.2 Operation·························································1
1.1.3 Maintenance ·····················································1
1.2 Packing List································································2
2.1 Working principle and functions·····································2
2.2 Specifications······························································3
2.3 Dimension Drawings····················································4
3. Installation Instruction
3.1 Position······································································5
3.2 Wall Mount·································································5
3.3 Ducting······································································5
3.4 Electric ····································································6-8
3.5 Condensate drainage ···················································9
4.1 Before startup···························································10
4.2 Default setting···························································10
4.3 Operating instruction··············································10-12
4.4 APP Instruction··························································13
4.5 RS485 Protocol·····················································14-18
5.1 Filter Replacement ······················································18
5.2 Drain Pipe Inspection ················································19
5.3 Inspection of air duct, air inlet/outlet·····························19
5.4 Heat exchanger cleanness············································19
6. Failure diagnosis·································································20
7. Optional Accessories····························································21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Comfort Fresh Air 250T and is the answer not in the manual?

Questions and answers

Summary of Contents for AlpicAir Comfort Fresh Air 250T

  • Page 1: Table Of Contents

    2.1 Working principle and functions·····································2 2.2 Specifications······························································3 2.3 Dimension Drawings····················································4 Models: 3. Installation Instruction 3.1 Position······································································5 ALPICAIR Comfort Fresh Air 250T 3.2 Wall Mount·································································5 3.3 Ducting······································································5 ALPICAIR Comfort Fresh Air 350T 3.4 Electric ····································································6-8 3.5 Condensate drainage ···················································9 ALPICAIR Comfort Fresh Air 500T 4.
  • Page 2: General Information

    General Information Product Introduction 1. General Information 1.2 Package 1.1 Safety Attention The package includes the following items. Please check when open the box. Please read the following safety instructions carefully before installation. In case of damage or incomplete delivery, please contact your supplier im- mediately.
  • Page 3: Specifications

    Product Introduction Product Introduction 2.3 Dimensions 2.2 Specifications ACFA-250T and ACFA-350T ACFA-250T ACFA-350T ACFA-500T Housing material Sprayed sheet metal Internal materials Heat exchanger Polystyrene materials Fan motor type Machine Filter class G4 or optional F7 Two screen controls, buttons + indica- Control Panel tor light/digital tube unit:mm...
  • Page 4: Position

    Installation Introduction Installation Introduction The operation process from right installation (factory default) to 3. Installation the left installation is as follows: 3.1 Position ·All installation of the system must be carried out by qualified personnel, including all electrical engineering and connections should be completed by qualified personnel or Electrician.
  • Page 5 Installation Introduction Installation Introduction Step3:Pull out the sockets from PCB for use. Step6:Finally, plug the sockets that has been wired back into the PCB, and cover the electric control box. Wiring Diagram Step4:Open the controller casing. Open the controller casing from here Step 5 Electrical heater signal...
  • Page 6: Condensate Drainage

    Installation Introduction Operation 3.5 Condensate drainage Before using, make sure to connect a condensate drain with this 4. Operation Instruction device. The connection process for condensate drain is as below: 4.1 Before Startup Please carefully check the followings: ·According to the installation way, install the drain connector and drain ·Check the voltage and frequency of the power source and its connection seal to the corresponding position.
  • Page 7 Operation Operation Panel 1 Instruction Panel 2 Instruction Error Speed control Bypass Bypass Bypass Speed button Defrosting Fan Boost Filter Frost Filter timer reset Speed control: Press to switch from Speed 1 to 4, speed 1 is “traveling mode”, when switch to this mode, the ventilator turns to super low speed. Fan Boost: Press to switch to the boost speed for 30 minutes, and then Air volume setting: Press “Speed”...
  • Page 8: App Instruction

    Operation Operation 4.4 APP Instruction 4.5 RS485 Protocol 1) Search “SMART LIFE” at the APP Store or scan the QR MODBUS-RTU Protocol details are as followed. code on the right to download the APP. 2) Sign up and log in your account. 3) Install the WIFI module onto the PCB board, as indi- Item Specifications...
  • Page 9 Operation Operation Address Range Default Function Remarks Bit0=OA temp and hum error Bit1=RA temp and hum error 0(0x0000) 0, 1 0=OFF 1=ON Bit2=OA temp error Bit3=RA temp error Every setting will reset 1(0x0001) 0-250 Filter used time (day) the current alarm Bit4=CO2 sensor error Bit5=reserved Fixed position are...
  • Page 10: Maintenance

    Operation Maintenance 5.Maintenance Bypass temperature differ- (0x001 2-15 ence(℃) 5.1 Filter replacement It’s recommended that all filters be inspected every 3 months and replaced 0=Electric Heater OFF (0x001 0, 1 1=Electric Heater ON once or twice a year, or be replaced when the “filter alarm” indicator on the control panel illumined.
  • Page 11: Drain Pipe Inspection

    Maintenance Failure Diagnosis 5.2 Drain pipe inspection 6.Fault diagnosis It’s recommended that the condensate drain pipe should be inspected once or twice a year, preventing the leakage due to poor drainage. Please inspect the machine refer to the table below if this product works 5.3 Air duct, air inlet/outlet inspection abnormally, and contact our service center to solve the problem in time.
  • Page 12: Optional Accessories

    Descriptions F7 filter for fresh air purification Remote touch screen controller BVT Partners group HQ Address: Vanaginės 37B, Didžioji Riešė, 14261 Main number: +370 52 753521 CO2 sensor E-mail: info@alpicair.com with 5 meter wire Website: www.alpicair.com ISO9000 ISO14001 WIFI Module...

Table of Contents