DR 7 NDT
EN
Installation and operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DR 7 NDT and is the answer not in the manual?

Questions and answers

Summary of Contents for Dürr NDT DR 7 NDT

  • Page 1 DR 7 NDT Installation and operating instructions...
  • Page 3: Table Of Contents

    Contents Contents Configuring the device in CRConfig / D-Tect 9.x.x and ScanX View ....Important information Configuring the unit in D-Tect X . . About this document .
  • Page 4: Important Information

    Important information Note, e.g. specific instructions regarding Important information efficient and cost-effective use of the unit. Refer to the accompanying electronic About this document documents. These installation and operating instructions rep- resent part of the unit. CE labelling Failure to comply with the instructions and information in these installation and Conformity mark for the United Kingdom operating instructions means that Dürr...
  • Page 5: Safety

    Important information Safety Specialist personnel Dürr NDT has designed and constructed this unit Operation so that when used in accordance with its Inten- Unit operators must use their training and knowl- ded Use there is no danger to people or prop- edge to ensure safe and correct handling.
  • Page 6: Disposal

    Important information Disposal Unit The unit must be disposed of properly. Within the European Union, the unit must be disposed of in accordance with EU Directive 2012/19/EU (WEEE). If you have any questions concerning the cor- ❯ rect disposal of the product, please contact DÜRR NDT or your specialist supplier.
  • Page 7: Product Description

    Scope of delivery The following items are included in the scope of delivery: DR 7 NDT ....2122100013 – Sensor Optional accessories...
  • Page 8: Technical Data

    Product description Technical data Unit Electrical data Rated voltage V DC Nominal current General technical data Dimensions W x H x D 31.5 x 50.0 x 8.3 1.24 x 1.97 x 0.33 Cable length sensor 177.17 Max USB cable extension 4,8 (see "3.2 Optional accessories") 188.98 Computer connection...
  • Page 9 Product description Ambient conditions during storage and transport Height above sea level < 16000 < 52493 2122100011L02 2304V004...
  • Page 10: Type Plate

    Product description Operation Type plate The X-ray sensor is connected to the computer The type plate is located on the sensor cable and via the sensor cable. on the case. The sensor is placed and activated via an imag- ing software (e. g. D-Tect). During the X-ray procedure, the x-rays are received by the scintillator (luminescent material) installed on the sensor and are converted into...
  • Page 11: Assembly 6 Requirements

    Connect the sensor USB connector to a free ❯ socket on the computer. Install driver(s) The drivers for the DR 7 NDT are automatically installed with the installation of D-Tect (from ver- sion 9.5) or D-Tect X. Connect the sensor USB connector to a free ❯...
  • Page 12: Configuration

    Assembly Configuration Change the unit name (Designation) as ❯ required. The unit supports the following imaging pro- grams: – D-Tect – ScanX View – D-Tect X – Third-party software on request Configuring the device in CRConfig / D-Tect 9.x.x and ScanX View Requirements: ü...
  • Page 13: Testing The Device

    Assembly Start irradiation. Testing the device ❯ A X-ray image can be taken to test whether the NOTICE unit has been connected correctly. Sensor damage and deterioration of Select the Test registration card. ❯ the image quality resulting from high exposure values in the free beam path With exposure values >...
  • Page 14 Assembly Start irradiation. ❯ NOTICE Sensor damage and deterioration of the image quality resulting from high exposure values in the free beam path With exposure values > 70 kV, protect ❯ the sensor accordingly. Comply with the maximum total dos- ❯...
  • Page 15: Usage

    Usage 11 Cleaning Usage NOTICE Equipment damage from moisture in 10 Operation the plug Before creating X-ray images, first calibrate the Do not spray the USB connector. ❯ device with the aid of the imaging software. – Offset calibration Unplug the unit. ❯...
  • Page 16: 12 Maintenance

    Usage 12 Maintenance The appliance is maintenance-free. 2122100011L02 2304V004...
  • Page 17: Troubleshooting

    Troubleshooting Troubleshooting 13 Tips for operators and service technicians Any repairs exceeding routine maintenance may only be carried out by qualified personnel or our service. 13.1 Poor X-ray image Error Possible cause Remedy No image transmission, X-ray dose too low Correct the exposure values.
  • Page 18 Troubleshooting Error Possible cause Remedy Error code E-1020 The current state of the sensor Disconnect and reconnect the ❯ does not permit image acquisi- USB connection cable. tion Sensor defective Inform your Service Techni- ❯ cian. Error code E-1026 Incorrect acquisition mode Select a different acquisition ❯...