Download Print this page

Pioneer DR-2111 Service Manual page 33

Advertisement

(
SI-V5089§-G
(
3/4
I
Modification procedure (if magnet was loose)
Step 1 to 10 as same as inspection
procedure.
12. Add LOCKTITE 648 between magnet and centering hub ( three places
).
(fig.2)
If glue ( LOCKTITE648 ) is not available replace a spindle motor ass'y ( .QXX2266
).
--"7
Glue
Centering hub
Fig.2
Magnet
13. Leave the unit more than 5 minutes and remove excessive LOCKTITE 648 by using cloth with absolute
alcohol.
Note: Make sure that alcohol should not touch table sheet on the turn table.
Do not put LOCKTITE 648 on the centering
hub.
4
0
0
14. Attache clamper ass'y.
Note: Make sure that clamper ass'y could
tun1
by hand.
15.
Attache top case.
Note: Make sure that fixing boss (two) are fit to hole on the top case.
16.
Attache front bezel
ass'y.
Note:
Make sure LED lines up to hole on the front bezel ass'y.
17. Attache bottom case and fix five scre\\;S in order as fig.3.
5--1--9~0
2
0
0
18. Turn on the power and open tray.
19. Attache tray name plate A.
20.
Place audio CD on the
tray.
21. Close tray and tum off the power.
Front bezel
Fig.3
22.
Make short of short terminal pins on the rear panel.(refer to "set up for an audio check")
23.
Turn on the power.
Dustproof sheet(DEC1861)
24. Make sure sound comes out.(You can check by using headphones)
25. Open tray and remove audio CD.
26. Turn off the power.
27. Remove short on terminal. (refer to "set up for an audio check")
In case of AT API model remove alligator
clip.
In case of SCSI model place back short pin.
28. Attache sheet on bottom case.
Make sure that front side two sheets should cover hooks of front
bezel ass'y.
(fig.4)
29.
Put marking on the serial label by using black
maker.
3

Advertisement

loading

This manual is also suitable for: