Komatsu ecot3 WA200-6 Shop Manual page 31

Table of Contents

Advertisement

200 Foreword and general information
Handling of electric equipment and hydraulic component
3)
Heavy duty wire connector (DT 8-pole, 12-
pole)
Disconnection (Left of figure)
While pressing both sides of locks (a)
and (b), pull out female connector (2).
Connection (Right of figure)
1]
Push in female connector (2) horizon-
tally until the lock clicks.
Arrow: 1)
2]
Since locks (a) and (b) may not be set
completely, push in female connector
(2) while moving it up and down until
the locks are set normally.
Arrow: 1), 2), 3)
a Right of figure: Lock (a) is pulled
down (not set completely) and
lock (b) is set completely.
(1): Male connector
(2): Female connector
(a), (b): Locks
WA200, 200PZ-6
q
Disconnection
SEN03872-00
q
Connection (Example of
incomplete setting of (a))
00-200
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecot3 wa200pz-6

Table of Contents