Download Print this page

COMBA CriticalPoint BBU V1 Quick Installation Manual

Annunciator panel
Hide thumbs Also See for CriticalPoint BBU V1:

Advertisement

Annunciator Panel
Quick Installation Guide
Version 1.0.4
BBU Software Firmware Requirements:
BBU V1 (CPBBUV1-48055-UL): V8B01 or newer
(Newest Firmware Rev: V8E01)
BBU V2 (CPBBUV2-48100-UL): V8101 or newer
(Newest Firmware Rev: V8501)
See BBU Manual for updating BBU Firmware
©2021 Comba Telecom. All Rights Reserved.
568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 |
www.combausa.com
1
Version 1.0.4
1.16.23

Advertisement

loading
Need help?

Need help?

Do you have a question about the CriticalPoint BBU V1 and is the answer not in the manual?

Questions and answers

Summary of Contents for COMBA CriticalPoint BBU V1

  • Page 1 BBU V2 (CPBBUV2-48100-UL): V8101 or newer (Newest Firmware Rev: V8501) See BBU Manual for updating BBU Firmware ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com Version 1.0.4...
  • Page 2: Table Of Contents

    Troubleshooting ..................................9 BBU Measurements ................................9 Annunciator Panel Measurements ........................... 10 Revision History ..................................11 ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com Version 1.0.4 1.16.23...
  • Page 3: Cabling

    Cabling The Comba’s CriticalPoint Annunciator Panel is powered and controlled by the Comba V1 or V2 Battery Backup Unit. A three-wire communication cable is required between the Comba BBU and the annunciator panel. Switch off the AC/DC power supply in the BBU and the power switch in annunciator panel before performing any cabling.
  • Page 4 For the BBU V2, power can be sourced from the MCU/control board 12VDC, 24VDC or Load Terminals to Annunciator Panel ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com...
  • Page 5 0V or Load - V_IN- From BBU 4. Power on the BBU and switch on power at annunciator panel ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com Version 1.0.4...
  • Page 6: Alarms And Dry Contact Output

    DC 1 DC 2 DC 3 DC 4 DC 5 DC 6 DC 7 DC 8 ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com Version 1.0.4 1.16.23...
  • Page 7: Software Configurations

    (OFF+OFF) and must be manually configured as (OFF+ON) when used in parallel as a secondary unit, see DIP switch example below. ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com...
  • Page 8: Alarm Setting

    To upgrade firmware: Click on “Add File”, select the new firmware file from your file explorer, then click on “Upgrade”. The device should upgrade then reboot. ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com...
  • Page 9: Troubleshooting

    1 to 2 ~ 50 Ohms 1 to 2 ~ 130 Ohms BBU V1 BBU V2 ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com Version 1.0.4 1.16.23...
  • Page 10: Annunciator Panel Measurements

    2 to 3 ~ 2.2k Ohms 1 to 2 ~ 130 Ohms Annunciator Panel Control Board ©2021 Comba Telecom. All Rights Reserved. 568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180 Ext 3 | www.combausa.com Version 1.0.4 1.16.23...
  • Page 11: Revision History

    6/13/22 Updated for firmware change to BBU & AP 1.0.2 6/28/22 Updated with R232 troubleshooting 1.0.3 1/13/23 Updated for dual annunciator panel operation and Comba Support contact information 1.0.4 1/16/23 Updated RS232 troubleshooting guide to include BBU V2 control board connection ©2021 Comba Telecom. All Rights Reserved.

This manual is also suitable for:

Criticalpoint bbu v2Cpbbuv1-48055-ulCpbbuv2-48100-ul