Operation

Basic Operation

Remote controller
1.
Start unit
Press ON/OFF
Start unit
2.
Select operation mode
COOL button:Cooling mode
DRY button: Dehumidify
mode
3.
Select temp. setting
button
Press
/
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
C,if kept depressed, it will
o
decrease . rapidly Select a desired
temperature.
Press
button to enter additional options, when
enter to FAN function.
Press FAN
button. For each press, fan speed
changes as
follows:
Remote controller:
LOW
MED
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
MODE
Remote
Operation
Mode
Controller
In COOL mode,the AC unit will emit Cool air according
to the remote setting on the temperature display The
COOL
Setting temperature is adjustable
In DRY mode , when room temperature becomes lower
DRY
th an temp.setting+2
LOW speed regardless of FAN setting.
In FAN operation mode , the unit will not operate in COOL or
FAN
HEAT mode but only in FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
Display
circulated
HI
AUTO
Note
C, unit will run intermittently at
o
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
Room
Timer
Designated
temperature
mode
temperature
Above 23
o
C
26
o
C
No
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
Test operation:
Test ope ration switch is the same as emergency switch.
Service personnel
Continue to press the test operation
switch for more than 5 seconds.After
you hear the "Pi" sound twice,release
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.

Air Flow Direction Adjustment

1.Status display of air flow
Vertical flap
Pos.1
Pos.2 No initial state disaplayed on remote controller, the
vertical flap will be fixed on the current position
2.Left and right air flow adjustment
For each press of
displays as follows :
remote controller:
Pos.1
Pos.3
Pos.2
Pos.5
Pos.6
Note: In some model: The remote has the button
the AC doesn't have the left and right air flow auto adjustment
function, this condition change the direction of ivertical blades
manually.
(the function only applicable for certain models)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
at air outlet if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward position
for a long time in COOL or DRY mode ,otherwise, condensate
water might occur.
Pi
Fan
Operation
speed