Download Print this page

Weber Flame iQ Owner's Manual

Suitable for the baby q series - q1000 and q1200 models only

Advertisement

Quick Links

OWNER'S GUIDE
FOR USE WITH UNIVERSAL LIQUEFIED PETROLEUM GAS (ULPG / LPG) ONLY
Thank you for purchasing the WEBER Flame iQ Accessory for your WEBER Baby Q.
Take a few minutes to read the manual.
Congratulations on the purchase of your WEBER Flame iQ
with patented technology.
The Flame iQ requires a 12 V or 240 V power supply. The
Flame iQ comes with a 2.4 metre 12 V power cable and a
1 metre 240/12 V power cable. This electrical connection
provides the Flame iQ with the ability to continually sense for
a flame.
WHAT IS THE WEBER Flame iQ?
The Flame iQ is a type of flame safeguard device, with added
features and benefits.
A flame safeguard device is designed to stop the flow of gas
to an appliance in the case that the gas flame goes out – for
example, if the flame is blown out in windy conditions.
The Flame iQ has the added functionality of continuously
sensing for a flame. It will attempt to reignite the burner in
the event of a 'flame out' (up to 3 attempts), before shutting
off the gas and going into a lockout mode. If the burner
reignites, the Flame iQ will reset for another 3 attempts.
HOW DOES THE WEBER Flame IQ WORK?
The Flame iQ features a sensing probe, situated on the
burner. If the probe senses a 'flame out', it sends a signal to
the Flame iQ, which then attempts to reignite the burner, up
to 3 times at 5 second intervals.
If the burner is not reignited by the third relighting attempt,
it will shut off the gas to the burner and go into lockout
mode. This is shown on the Flame iQ when the reset light is
illuminated (refer to lighting instructions on page 7).
If the burner is successfully reignited on the first, second or
third attempt, the Flame iQ resets itself (and will attempt 3
reignitions if the probe again senses a 'flame out').
TM
SUITABLE FOR THE BABY Q SERIES - Q1000 AND Q1200 MODELS ONLY
ADDITIONAL BENEFITS OF USING THE WEBER Flame iQ
WITH YOUR WEBER Baby Q
The Flame iQ meets the requirements of the Australian
& New Zealand Standard for Outdoor Gas Appliances
for barbecues connected to the piping on a caravan or
boat. Once your Baby Q is fitted with a Flame iQ, it can
be connected to the plumbed gas supply of a boat or
caravan.
Should the flame in your Baby Q blow out due to strong
winds, the Flame iQ will sense a 'flame out' and attempt
to re-ignite the burner. This will be seamless and happen
continuously whenever the flame is blown out (if the
burner is reignited within 3 attempts at each 'flame out').
Your food will still be cooked through perfectly.
When the Flame iQ is turned on, it runs a self-check to
ensure that there is no flame present on the burner. If
there is a flame present the Flame iQ will go into reset
mode. This ensures that the Flame iQ is in the correct
safe start position with no gas flowing through the Flame
iQ.
Easy-to-see indicator lights on the Flame iQ control
panel mean you don't have to lift the lid of your barbecue
to see if it's alight.
The lights indicate:
a) Green light illuminated - Flame iQ is ready to operate.
b) Blue light illuminated - flame detected at burner.
c) Blue light off - flame out detected and reignition being
attempted.
d) Red light illuminated - lockout mode due to
unsuccessful reignition.
A pre-set maximum run time of 8 hours is built into the
Flame iQ, meaning that if you forget to turn your Baby Q
off after use, it will automatically cut the gas supply to
the barbecue after 8 hours of continuous run time.
SCAN FOR ASSEMBLY
AND HOW TO USE
INSTRUCTIONS
1
WWW.WEBER.COM

Advertisement

loading

Summary of Contents for Weber Flame iQ

  • Page 1 INSTRUCTIONS FOR USE WITH UNIVERSAL LIQUEFIED PETROLEUM GAS (ULPG / LPG) ONLY Thank you for purchasing the WEBER Flame iQ Accessory for your WEBER Baby Q. Take a few minutes to read the manual. Congratulations on the purchase of your WEBER Flame iQ ADDITIONAL BENEFITS OF USING THE WEBER Flame iQ with patented technology.
  • Page 2: Dangers & Warnings

    This instruction manual contains important information necessary for the proper assembly and safe use of the Weber Flame iQ. Read and follow all warnings and instructions before fitting and using the Flame iQ accessory. Keep this manual for future reference. Carefully follow all leak-check procedures in this Owner’s Guide. Do not use the Flame iQ without first reading the burner ignition sections in this manual.
  • Page 3: Table Of Contents

    FITNESS FOR A PARTICULAR PURPOSE, OTHER THAN WHAT IS it was purchased as a gift or promotional item), that the WEBER EXPRESSLY MADE IN THIS LIMITED WARRANTY. NO WARRANTIES...
  • Page 4: Parts List

    Lay the barbecue and behind the manifold/valve (ensure on it’s back for ease of access and remove the Flame iQ is on the outside of the the mounting screws using the supplied attachment bracket). Loosely connect by 1/4”...
  • Page 5: Assembly

    15. Screw the hose and regulator assembly bracket with the 2 screws using a phillips position, but not attached to the manifold/ to the inlet of the Flame iQ using the 3/4” head screwdriver. valve. spanners. Ensure you only tighten the nut on the hose.
  • Page 6: Leak Check

    (1). Turn gas supply on at source (2). WARNING: Do not ignite burner when leak checking. Plug Flame iQ to power source (3A) and press the ON button (3B). To check for leaks, wet fittings with the soap and water solution, using a spray bottle, brush or rag.
  • Page 7: Burner Ignition & Usage

    RESETTING THE Flame iQ AFTER FLAME FAILURE AND LOCKOUT Depress the RESET button (illuminated red) continuously ON/OFF for five (5) seconds to reset the Flame iQ (red light will go out). Repeat the ignition steps as above. TO EXTINGUISH BURNER RESET...
  • Page 8: Troubleshooting

    You have 30 seconds to ignite the barbecue after turning on the Flame iQ device. Refer burner ignition on page 7. If the barbecue does not ignite, the Flame iQ will lock-out, the gas flow will stop, and the red reset light will illuminate.