  • Page 1 QuantaGrid Series D52BQ 3UPI-2U Scale Along with Your Business User’s Guide Version : 1.0...
  • Page 2 For the latest information and updates please see www.qct.io All the illustrations in this guide are for reference only and are subject to change without prior notice.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS ABLE OF ONTENTS About the System Introduction ............1-1 System Features.
  • Page 4 ONVENTIONS Conventions Several different typographic conventions are used throughout this manual. Refer to the following examples for common usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders, menus, programs, and files.
  • Page 5 RECAUTIONARY EASURES Precautionary Measures Read all caution and safety statements in this document before performing any of the instructions. To reduce the risk of bodily injury, electrical shock, fire, and equipment dam- age, read and observe all warnings and precautions in this chapter before installing or maintaining your system.
  • Page 6 RECAUTIONARY EASURES Table 1: Warning and Cautions (Continued) The enclosure is designed to carry only the weight of the system sled. Do not use this equipment as a workspace. Do not place additional load onto any equipment in this system. Indicates two people are required to safely handle the system.
  • Page 7 RECAUTIONARY EASURES Equipment Handling Practices Reduce the risk of personal injury or equipment damage: Conform to local occupational health and safety requirements when moving and  lifting equipment. Use mechanical assistance or other suitable assistance when moving and lifting  equipment.
  • Page 8 RECAUTIONARY EASURES Rack Mount Warnings The following installation guidelines are required by UL for maintaining safety compliance when installing your system into a rack. The equipment rack must be anchored to an unmovable support to prevent it from tip- ping when your system or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions.
  • Page 9 RECAUTIONARY EASURES Electrostatic Discharge (ESD) CAUTION! CAN DAMAGE DRIVES BOARDS AND OTHER PARTS E RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN WORKSTATION F ONE IS NOT AVAILABLE PROVIDE SOME PROTECTION BY WEARING AN ANTI STATIC WRIST STRAP ATTACHED TO CHASSIS GROUND ANY UNPAINTED METAL SURFACE ON YOUR SERVER WHEN HANDLING PARTS...
  • Page 10 RECAUTIONARY EASURES ified in this manual. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in non-compliance with product regulations in the region(s) in which the product is sold. System power on/off: To remove power from system, you must remove the system from rack.
  • Page 11 RECAUTIONARY EASURES The system is designed to operate in a typical office environment. Choose a site that is:  Clean and free of airborne particles (other than normal room dust).  Well ventilated and away from sources of heat including direct sunlight. ...
  • Page 12 RECAUTIONARY EASURES Structure of this guide Chapter 1: About the System  “This section introduces the system, its different configuration(s) and the main features.” Chapter 2: Regulatory and Compliance Information  “This section provides regulatory and compliance information applicable to this system.”...
  • Page 13: About The System

    About the System Chapter 1 This section introduces the system, its different configuration(s) and the main features.
  • Page 14: Introduction

    This document provides an overview of the hardware features of the chassis, troubleshooting information, and instructions on how to add and replace components of the server. For the latest version of this manual, see www.qct.io. System Features The system comprises a 2U/30.7” long chassis. Major features include: ®...
  • Page 15 BOUT THE YSTEM YSTEM EATURES Table 1.1: System Specifications (Continued) PECIFICATIONS ESCRIPTION Processor type: Intel® Xeon® Processor Scalable Family (codename Skylake-SP) Max. TDP support: Processor 205W, Optimized power delivery for 85W, VRD 13 Number of processors: 2 Internal Interconnect: 10.4 GT/s, 9.6 GT/s ®...
  • Page 16 (2) LP x16 CPU1 CPU0 Expansion slot-Riser slot3 (Gen3 x32, CPU0+CPU1) PCIe x16, CPU0 Riser PCIe x16, CPU1 Slot 3  (1) PCIe x8 mini-PCIe slot reserved for QCT SAS mezzanine card CPU1 CPU0 Expansion slot-Riser slot4 Riser (Gen3 x8, CPU0) Slot4...
  • Page 17 Storage installed on riser slot4 3.5” SKU:  12x SATA/SAS HDD/SSD, 3.5” x12 HDD backplane board with QCT LSI SAS3516 mezzanine card installed on riser slot4 (2) M.2 SATA 2280 on riser slot2 assembly (SATADOM replacement)* Onboard storage *The M.2 2280 SATA SSD supports OS installation only/M.2 2280 SATA SSD sig-...
  • Page 18 BOUT THE YSTEM YSTEM EATURES Table 1.1: System Specifications (Continued) PECIFICATIONS ESCRIPTION (6) dual rotor fans (11+1 redundant)* *Hot-swap feature will be available only while the Cable Management Arm (CMA) is installed. System management IPMI v2.0 Compliant, on board "KVM over IP" support ...
  • Page 19: Package Contents

    BOUT YOUR YSTEM ACKAGE ONTENTS 1.2 Package Contents (1) D52BQ 3UPI-2U system  (2) processor heat sinks  (1) power supply unit  (1) power cord (optional)  Note: Note: For exact shipping contents, contact your QCT sales representative.
  • Page 20: A Tour Of The System

    BOUT THE YSTEM OUR OF THE YSTEM 1.3 A Tour of the System System Overview The server is available as a 2.5” and 3.5” storage drive configuration. The 2.5” storage drive system overview is displayed in the following image: 4 12 14 15 Figure 1-1.
  • Page 21 Riser slot1B PCIe Gen3 x16, support riser slot1 assembly (#15) installation Riser slot4 PCIe Gen3 x8, support QCT SAS mezzanine card assembly installation PSU assembly Redundant power supply unit assembly (PSU) Riser card features (2) PCIe x16 slots on riser slot3 Riser card features (1) PCIe x16 slot and (2) M.2 2280 SATA (SATADOM...
  • Page 22 BOUT THE YSTEM YSTEM VERVIEW The 3.5” storage drive configuration system overview is displayed in the following image: Figure 1-2. 3.5” Storage Drive System Component Overview Table 3: Component Overview ESCRIPTION Two server handles used for pulling the system out of the rack CAUTION! Handles ANDLES ARE DESIGNED FOR THE EXTENSION OF THE SYSTEM FROM THE RACK...
  • Page 23: System Front View

    Riser slot1B PCIe Gen3 x16, support riser slot1 assembly (#15) installation Riser slot4 PCIe Gen3 x8, support QCT SAS mezzanine card assembly installation PSU assembly Redundant power supply unit assembly (PSU) Riser card features (2) PCIe x16 slots on riser slot3 Riser card features (1) PCIe x16 slot and (2) M.2 2280 SATA (SATADOM...
  • Page 24 BOUT THE YSTEM YSTEM RONT Table 4: Front View (Continued) ESCRIPTION Maximum display resolution: 1920x1200 32bpp@60Hz VGA port (reduced blanking) (Display Priority: First; one device one time) Two server handles used for pulling the system out of the rack CAUTION! Handle ANDLES ARE DESIGNED FOR THE EXTENSION OF THE SYSTEM FROM THE RACK ANDLES ARE NOT DESIGNED TO CARRY THE WEIGHT OF THE SYSTEM...
  • Page 25: Front Control Panel (Fcp)

    BOUT THE YSTEM YSTEM Front Control Panel (FCP) For purposes of this procedure, the FCP is used for the numbering indicators. Figure 1-5. Front Control Panel and Connectors Table 6: Front Control Panel Definition ESCRIPTION Power on / off Power button with Blue on - S0 system power on;...
  • Page 26: System Rear I/O

    BOUT THE YSTEM YSTEM Table 7: System Rear View (Continued) EATURE ESCRIPTION System I/O ports See System Rear I/O on page 1-13 Expansion slot Support OCP 2.0 mezzanine card installation (CPU0) Power sub-system Main power supply unit (PSU0). See Power Sub-System on page 1-14. Expansion slots PCIe expansion slot with FHHL (CPU0) Expansion slots...
  • Page 27: Power Sub-System

    LED S BOUT THE YSTEM TATUS EFINITIONS Power Sub-System PSU LED Figure 1-8. PSU to Mainboard Module Description A single power supply unit (default) is supplied in the system. A secondary PSU is available for redundancy functionality. Table 9: Power Supply Units by Model AC I NPUT 2 x 800W and 1200W Titanium/Platinum...
  • Page 28: Bmc Management Port Leds

    LED S BOUT THE YSTEM TATUS EFINITIONS Power LED Status LED ID LED Figure 1-9. Front Control Panel LEDs Table 11: Front Control Panel LEDs Behavior OLOR ONDITION ESCRIPTION System S0 power on Power LED Blue System S5 power off Blinking Unit selected for identification Identification...
  • Page 29: Storage Drive Led

    LED S BOUT THE YSTEM TATUS EFINITIONS Table 12: RJ45 LED Description (Continued) ONDITION CTIVITY 10M active link Blinking green Storage Drive LED Front/Rear 2.5” Storage Drive LED Status Behavior Active LED Status / Fault LED Figure 1-11. 2.5” Storage Drive LED Identification The following LED behavior table represents LED conditions.
  • Page 30: Nvme Ssd M.2 Adapter Add-On Card (Optional)

    SSD M.2 A BOUT THE YSTEM DAPTER PTIONAL The following LED behavior table represents LED conditions. Table 14: 3.5” Storage Drive LED Status Behavior OLOR ONDITION ESCRIPTION Drive is online Blue Twice per second: Identification Blinking Once per second: Rebuilding Drive Status / Fault Amber HDD failure...
  • Page 31: Enabling The Intel® Vmd Technology

    ® VMD BOUT THE YSTEM NABLING THE NTEL TECHNOLOGY Enabling the Intel® VMD technology Note: You can use Intel® VROC HII to create the RAID volume. These volume can be created at any point before or after your system is successfully running your Windows installation, but may not be used as the boot vol- ume.
  • Page 32: Spanning Raid Data Volumes Across Vmd Domains

    RAID BOUT THE YSTEM PANNING DATA VOLUMES ACROSS DOMAINS Then you can enable/disable the Intel® VMD feature for your system. Table 16: Intel® VMD on Socket X Screen Description ETUP PTIONS OMMENTS VMD Config for PStack0 Information only. Intel® VMD for Volume [Disable] Enable/Disable Intel®...
  • Page 33 RAID BOUT THE YSTEM PANNING DATA VOLUMES ACROSS DOMAINS 2. Navigate to and select “Intel(R) Virtual RAID on CPU”. 3. Navigate to and select “All Intel VMD Controllers” 1-20...
  • Page 34 RAID BOUT THE YSTEM PANNING DATA VOLUMES ACROSS DOMAINS 4. Navigate to and select “Create RAID Volume” 5. To enable the RAID to be spanned over multiple controllers, highlight the [ ], and press <Enter>. This will open a small menu box with two values, blank and X. Blank indicates a setting that is disabled.
  • Page 35: Enabling Platform Trusted Technology (Ptt)

    (PTT) BOUT THE YSTEM NABLING LATFORM RUSTED ECHNOLOGY 6. Navigate to and select Create Volume, then press <Enter>. 7. The following message will be displayed: “You have selected NVMe drives that are connected to multiple VMD controllers. Please note that if you continue and create a RAID volume with drives from multiple VMD controllers that RAID volume will not be bootable in a Windows* OS environment.
  • Page 36: Tpm Configuration Settings

    BOUT THE YSTEM CONFIGURATION SETTINGS arrow until the Platform Configuration screen is chosen. Press the down arrow key until “Server ME Configuration” is selected. Press down arrow key to select PTT Support. Then you can enable/disable the PTT feature for your system TPM configuration settings To setup the TPM configuration, you might need to select “Trusted Computing”...
  • Page 37 BOUT THE YSTEM CONFIGURATION SETTINGS Table 17: Configuration on Trusted Computing Screen Description (Continued) ETUP PTIONS OMMENTS Available PCR Information only. Displays cur- banks rent available PCR banks. [Disabled] Enable or Disable SHA-1 PCR Only appears when “Available SHA-1 PCR Bank Bank PCR banks”...
  • Page 38: Regulatory And Compliance Information

    Regulatory and Compliance Information Chapter 2 This section provides regulatory and compliance information applicable to this system.
  • Page 39 Server Safety Information To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or maintaining your server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 40 Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than an ITE application, may require further evaluation.
  • Page 41 When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing it from the server. To avoid risk of electric shock, turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Power Cord Warnings If an AC power cord was not provided with your product, purchase one that is approved for use in your country.
  • Page 42 Rack Mount Warnings Note: The following installation guidelines are required by UL for maintaining safety compliance when installing your system into a rack. The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions.
  • Page 43 Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery. Cooling and Airflow Caution: Carefully route cables as directed to minimize airflow blockage and cooling problems. For proper cooling and airflow, operate the system only with the chassis covers installed. Operating the system without the covers in place can damage system parts.
  • Page 44 After you have completed the six SAFETY steps above, you can remove the system covers. To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3.
  • Page 45 The rail racks are designed to carry only the weight of the server system. Do not use rail-mounted equipment as a workspace. Do not place additional load onto any rail-mounted equipment. Heavy object. Indicates four or more people are required to safely handle the system.
  • Page 46 Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 47 Updated product information for configurations can be found on the site at the following URL: www.qct.io If you do not have access to the Web address, please contact your local representative. Add-in cards: must have a printed wiring board flammability rating of minimum UL94V-1.
  • Page 48 商品報驗資訊 商品名稱:伺服器 報驗義務人名稱:廣達電腦股份有限公司 報驗義務人地址:桃園市龜山區文化里文化二路188號 限用物質含有情況標示聲明書 Declaration of the Presence Condition of the Restricted Substances Marking 設備名稱: 伺服器 ,型號(型式): D52BQ -2U Equipment name Type designation (Type) 限用物質及其化學符號 Restricted substances and its chemical symbols 六價鉻 多溴聯苯 多溴二苯醚 單元 Unit 鉛 汞 鎘 Lead Mercury Cadmium...

This manual is also suitable for:

Quantagrid seriesQuantagrid d52bq-2u

Table of Contents