OPERATION PARAMETERS WARNING!! The following conditions for feed water supply must be met or Warranty will be void. Unit MUST be connected to a municipal or well water source that is treated and tested on a regular basis to insure water is microbiologically safe. Operating temperatures: Maximum: 105°...
PLUMBING SCHEMATIC PLUMBING SCHEMATIC FOR 1 & 2 STAGE UNDER COUNTER FILTER SYSTEMS (U2000 - 2 Stage Under the Counter Model shown). FAUCET METAL BALL VALVE FEEDWATER ADAPTER FLOWLOK CAUTION!! DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE or of unknown quality without adequate disinfection before or after the system.
PRE & FAUCET INSTALLATION IMPORTANT!! PLEASE READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL. 1. PRE-INSTALLATION PROCEDURE This unit includes a standard sink top faucet without an air-gap. In localities where plumbing codes require installation of an air-gap, contact your local distributor to obtain a code approved drain line adapter.
Page 7
FAUCET INSTALLATION (Continued) REMOVE EVERYTHING FROM INSIDE THE SINK AND SURROUNDING AREA. Place paper towels in the sink to catch the shavings from the grinding and drilling. Using a cordless drill with a carbide grinding burr, gently grind away enough porcelain or enamel to more than accommodate the 7/16”...
Page 8
DIAGRAMS B, C, D, & E DIAGRAM B (For Faucet Installation Steps 10-14) UP FOR CONSTANT FULL FLOW MIDDLE POSITION FOR OFF DOWN FOR CONTROLLED FLOW CHROME WASHER RUBBER GASKET SMALL BLACK GASKET STAR LOCK WASHER BLACK PLASTIC WASHER CHROME NUT SHANK DIAGRAM C 1/4”...
FEEDWATER ADAPTER 3. INSTALLATION OF FEEDWATER ADAPTER CAUTION!! For your safety and protection, do not use where water is microbiologically unsafe or of unknown quality. The water supply to your system MUST be from the COLD WATER LINE! Hot water will severely damage your filtration system! Turn off cold water supply to the sink using the supply valve located under the sink.
UNIT PLACEMENT & FLOWLOK INSTALLATION 4. WATER FILTRATION SYSTEM PLACEMENT AND MOUNTING The system does not need to be mounted on the wall of the cabinet and simply sits on the floor of the cabinet. IMPORTANT!! Be very careful not to kink any of the tubing on the water filtration system. If tubing is kinked the tubing can rupture and leak.
TUBING & QUICK CONNECT FITTINGS 6. TUBING CONNECTIONS IMPORTANT!! Be very careful not to kink any of the tubing on the water filtration system. If tubing is kinked the tubing can rupture and leak. CONNECTING THE SYSTEM: (BLUE TUBING - From system faucet port. This is from port labeled faucet) Connect the blue tubing to the faucet by slipping the 1/4”...
Page 12
QUICK CONNECT FITTINGS HOW TO MAKE QUICK CONNECT FITTINGS CONNECTIONS: (Continued) INSERT TUBING Push the tubing through the collet and o-rings until it bottoms out against the tube stop. The collet holds the tube in place and the o-ring provides a leak resistant seal. If you need to remove the tubing always re-cut before connecting tubing again.
SYSTEM START UP & FLUSHING RO SYSTEM 7. SYSTEM START-UP With all connections complete, turn on the cold water supply to the filtration system IMPORTANT!! The Water Filtration Systems Main Water Shut Off valve (indicated by the bright orange tag at the side of the unit) must be open. This means the blue handle on the valve must be in the horizontal position.
FILTER REPLACEMENT 9. FILTER REPLACEMENT INSTRUCTIONS (U2000 - 2 Stage Under the Counter Model shown). STEP 1 STEP 2 STEP 3 TURN WATER OFF OPEN SYSTEM FLIP SYSTEM Turn Ball Valve Main Water Shut-Off Remove cover and Flip system and Blue handle to vertical position Hydro Guard™...
TROUBLESHOOTING TROUBLESHOOTING NOT ENOUGH WATER POSSIBLE CAUSE / SOLUTION Feed water valve is plugged Open valve or unclog. or closed. Sediment/Carbon prefilter or Replace Filters. Carbon Post Filter is clogged. Incoming water pressure must be above 40 PSI. Install Low incoming water pressure. a Booster Pump or Permeate Pump.
Page 16
SERVICE RECORDS SERVICE RECORD CARTRIDGE CARTRIDGE CARTRIDGE CARTRIDGE DATE...
LIABILITY & WARRANTY LIABILITY WARNING!!! The installer is responsible for any leaks resulting from installation of tubing or related fittings. T HE I NSTALLER M UST C HECK O VER T HE E NTIRE S YSTEM COMPLETELY W HILE UNDER PRESSURE TO ENSURE SYSTEM IS NOT LEAKING AND FUNCTIONING PROPERLY. Liability resulting from failure to check for leaks under pressure is the sole responsibility of the installer.