CONFIGURATOR
Dominator BT
User manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dominator BT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mechatronics Dominator BT

  • Page 1 1.01 CONFIGURATOR Dominator BT User manual...
  • Page 2: Table Of Contents

    5.1 Sensor calibration 5.2 Tank calibration 5.3 Sensor/tank calibration in inactive mode Firmware update Data logging Additional information 8.1 Technical support 8.2 Contacts Appendix I. Connecting Dominator BT to Teltonika FMB devices Appendix II. Dominator BT message format Appendix III. Status parameter...
  • Page 3 1.01 Configurator Dominator BT USER MANUAL ERMS AND DEFINITIONS eurosens FLS – fuel level sensor App – application Calibration – changing of sensor settings PC – personal computer...
  • Page 4: General Information

    ENERAL INFORMATION _____________________________________________________________________________________ The application "Configurator Dominator BT" (app) is designed to calibrate, monitor and test eurosens Dominator BT fuel level sensors (FLS) manufactured by Mechatronics JSC. To calibrate the sensor, you will need: • Android Smartphone (ver. 9.0 or newer);...
  • Page 5: Installation

    2. During the installation provide all required permissions to the app and enable Bluetooth access and geolocation services (fig. 2.1). fig. 2.1. Permissions 3. Start the app and follow the instructions. 4. During the first start fill in the registration form and sent it to Mechatronics (fig. 2.2 fig. 2.3).
  • Page 6 1.01 Configurator Dominator BT USER MANUAL fig. 2.2. Filling in registration form fig. 2.3. Sending registration form...
  • Page 7 1.01 Configurator Dominator BT USER MANUAL 5. After the data has been verified by the manager, your account will be added to the list of accounts in Android Settings - > “Accounts”. 6. Restart the app after you complete the registration process.
  • Page 8: Operation

    1.01 Configurator Dominator BT USER MANUAL PERATION _____________________________________________________________________________________ The FLS is supplied in an inactive state to save battery power. 1) After the application is installed and registered, check if the required permissions, Bluetooth module and geolocation services are enabled.
  • Page 9 1.01 Configurator Dominator BT USER MANUAL 5) Activate the settings mode of the sensor for further setup and calibration: take the magnetic key from the sensor’s kit and apply it to the icon of magnet on sensor’s case for 2-3 seconds (fig.
  • Page 10 1.01 Configurator Dominator BT USER MANUAL fig. 3.3. Tab “Information” Do not click the button "Switch to the firmware update mode" if the update is not planned. Leaving the sensor in the firmware mode can lead to a rapid discharge...
  • Page 11: Settings

    1.01 Configurator Dominator BT USER MANUAL ETTINGS _____________________________________________________________________________________ The following settings can be performed in the tab “Settings” (fig. 4.1): fig. 4.1. Tab “Settings” • Messages delivery period (sec) is the time interval between messages being sent to the monitoring system. The default value is 5 seconds (a shorter period will reduce battery life of the sensor), a longer value will save the battery power).
  • Page 12 1.01 Configurator Dominator BT USER MANUAL • Thermocompensation recalculates fuel volume by temperature and makes sensor readings temperature dependent (requires a more precise calibration). • Standard temperature is reference fuel temperature for the thermal compensation (also the generally regulated fuel temperature at filling stations).
  • Page 13 1.01 Configurator Dominator BT USER MANUAL • Load from sensor – load configuration and tank calibration from sensor. • Load from file - load configuration and tank calibration from file. • Save to sensor – save configuration and tank calibration in sensor.
  • Page 14: Calibration

    1.01 Configurator Dominator BT USER MANUAL ALIBRATION _____________________________________________________________________________________ Create and edit a tank calibration table in the tab “Calibration”. • Tank calibration table is necessary to make sensor output proportional to current volume in the tank (not level). It is sufficient to have 2 calibration points in a table for a rectangular tank or vertical cylinder tank of “ideal shape”.
  • Page 15: Sensor Calibration

    1.01 Configurator Dominator BT USER MANUAL • Click on a row to edit detector or fuel volume values. The buttons "+" and “-” add and delete points. • Sensor calibration (or a 2-point tank calibration) can be performed without a table.
  • Page 16: Tank Calibration

    1.01 Configurator Dominator BT USER MANUAL If table contains more than two rows, the buttons "Calibrate Empty" and "Calibrate Full" disappear, since the tank calibration mode goes automatically. Sensor calibration is not necessary if you perform the tank calibration and save the table to sensor (not GPS tracking server).
  • Page 17 1.01 Configurator Dominator BT USER MANUAL fig. 5.4. Calibration • Table in Wialon format If the option "Table in Wialon format" is enabled (fig. 5.5), the values of portion volumes change into the total volume value, which increases with each calibration step.
  • Page 18 1.01 Configurator Dominator BT USER MANUAL Before saving the calibration table to sensor in Wialon format, save the table to a file in the standard format. fig. 5.5. Table in Wialon format • Autosave The enabled option “Autosave” opens the menu for saving the table to a file each...
  • Page 19: Sensor/Tank Calibration In Inactive Mode

    1.01 Configurator Dominator BT USER MANUAL 5.3 S ENSOR TANK CALIBRATION IN INACTIVE MODE If sensor calibration or tank calibration (most likely) takes more than an hour, it is recommended to perform calibration in the inactive mode then in order to reduce the battery drain: 1.
  • Page 20 1.01 Configurator Dominator BT USER MANUAL 3. Go to the tab “Calibration” and calibrate the FLS or tank as described before. There could be delays in receiving messages up to 30 seconds depending on smartphone model. It is recommended to save the calibration table to a file after each calibration point.
  • Page 21: Firmware Update

    2. Download the latest firmware for the receiver. 3. Switch the receiver to firmware update mode: • Go to the tab “Information” in the configurator Dominator BT app and choose “Switch to the firmware update mode”; • Confirm the action (fig.
  • Page 22 1.01 Configurator Dominator BT USER MANUAL fig. 6.2. “Browser” tab fig. 6.3. «ОТА” device 6. Click the button "..." in the upper right corner and select the item “OTA DFU” (fig. 6.4). fig. 6.4. “OTA DFU”...
  • Page 23 1.01 Configurator Dominator BT USER MANUAL 7. Select the firmware file in the window that appears, and click “OTA” (fig. 6.5). fig. 6.5. Choosing the firmware file After the firmware update process is complete, the device will automatically exit...
  • Page 24: Data Logging

    1.01 Configurator Dominator BT USER MANUAL ATA LOGGING _____________________________________________________________________________________ Sensors equipped with a memory module are able to log the data. In log mode you can view graphs of temperature and fuel level data for a selected period of time.
  • Page 25: Additional Information

    1.01 Configurator Dominator BT USER MANUAL DDITIONAL INFORMATION _____________________________________________________________________________________ 8.1 T ECHNICAL SUPPORT +37525-691-87-76 +37525-691-87-76 support@mechatronics.by 8.2 C ONTACTS JSC Mechatronics 80/3 1 May Street Vileyka, 222416 Belarus t: +375 (1771) 71300 f: +375 (1771) 24190 E-mail: office@mechatronics.by www.mechatronics.by/en...
  • Page 26: Appendix I. Connecting Dominator Bt To Teltonika Fmb Devices

    1.01 Configurator Dominator BT USER MANUAL PPENDIX ONNECTING OMINATOR ELTONIKA DEVICES _____________________________________________________________________________________ In this example Teltonika FMB900 is used. 1. Connect GPS tracker to the PC and start the Teltonika configurator. 2. Go to the Bluetooth 4.0 section. 3. In the field “Connection # 1” select the “Advanced” mode.
  • Page 27 • 24_1 Temperature - Temperature. • 25_1 Battery – the battery level. • You can load eurosens Dominator BT preset file instead of manual filling. 7. Check the received data in the field "Status" after the settings are finished (fig.I- 3, fig.I- 4...
  • Page 28 1.01 Configurator Dominator BT USER MANUAL fig.I- 3. Checking received data fig.I- 4. Checking received data...
  • Page 29 1.01 Configurator Dominator BT USER MANUAL fig.I- 5. Checking received data...
  • Page 30: Appendix Ii. Dominator Bt Message Format

    1.01 Configurator Dominator BT USER MANUAL II. D PPENDIX OMINATOR MESSAGE FORMAT _____________________________________________________________________________________ Table 1. Protocol ver.1 Field name Specification Example Offset, bytes Length, bytes 48-bit Unique constant 0x795FB8622ЕB6 Identifier (UID) Type constant 0x5A (dec 90) Serial number constant...
  • Page 31 1.01 Configurator Dominator BT USER MANUAL Table 2. Protocol ver.2 Field name Specification Example Offset, bytes Length, bytes 40-bit Unique constant 0x3f36b4fdbe Identifier (UID) Type constant 0x5A (dec 90) Serial number constant 0x00001B (dec Message number Message Overwrite 0x0003CA36...
  • Page 32: Appendix Iii. Status Parameter

    1.01 Configurator Dominator BT USER MANUAL III. S PPENDIX TATUS PARAMETER _____________________________________________________________________________________ Table 3. Status parameter. Description Bit number Sensor locked Calibration error empty Full calibration error Broken electrode Reserve...
  • Page 33 1.01 Configurator Dominator BT USER MANUAL...