  • Page 1 FAIATEIS INTERNATIONAL PPM-IT5 manual Professionnal IP Paging console...
  • Page 2: For Your Safety

    Do not use benzene, thinner, or chemicals to clean the PPM-IT5. Use only a soft, dry • cloth. If the PPM-IT5 is moved from a cold place (e.g. overnight in a car) to a warmer • environment, condensation may form inside the unit, which may affect performance.
  • Page 3: Table Of Contents

    Main ............................23 HOW TO ............................23 Know its IP address ......................... 23 Add a prerecorded message into the PPM-IT5 ..............23 Change the chime ........................24 Set up the time.......................... 24 Start an event with the scheduler ..................24 Control an ECS with the PPM-IT5 ..................
  • Page 4: Ateis Introduction

    ATEIS INTRODUCTION WELCOME Thank you for choosing ATEÏS PPM-IT5. We hope you will enjoy using this exciting piece of technology as much as we enjoy developing and building it. This manual can be updated at any time without prior notice in order to keep this manual up to date.
  • Page 5: Contacts

    Ateïs Middle East Building SEA, room 324, DAFZA, DUBAÏ, United Arab Emirats Phone: +971 4609 1325/24 Fax: +971 4609 1326 Web, contact: http://www.ateis-international.com/ Ateïs France 34, avenue de l’Europe, Z.A Font Ratel, CLAIX, FRANCE Phone: +33 (0) 4 76 99 26 30 Fax: +33 (0) 4 76 99 26 31 Web, contact: http://www.ateis-france.fr/...
  • Page 6: Machine

    All the settings are done through web pages with your favourite web browser. Thanks to powerful echo cancellation, the PPMIT5 delivers clear sound for full duplex talk. PPM-IT5 belongs to the TERRACOM range, the new ATEÏS Audio over IP solution. MACHINE 1 5”...
  • Page 7: Installation

    Control Depending on your needs, there are several ways of configuring and controlling the PPM- IT5. Embedded web server enables you to modify the settings of the PPM-IT5. TERRA-SERVER, our intuitive and powerful audio distribution software, handles the announcement, the music, the zoning, the paging, the scheduler & the priorities.
  • Page 8 N.B:You don’t need to set up the Gateway if all the devices are in the same LAN (local area network). You don’t need to set up the DNS if the PPM-IT5 is not synchronised with an external NTP server. Reboot.
  • Page 9 If you create a direct link without SIP and the target device is in the same LAN than your device: Even if you are not using a SIP server, the TERRACOM devices will use a SIP connection (transparent for you). Then select Terranet for the Firewall Traversal Mode and set up the same SIP port value for each TERRACOM device.
  • Page 10: Firmware Update

    This group can be linked to a button on the touchscreen. Firmware Update Ateis provides regularly new firmwares, then please check on our webpages if there is any new firmware for the PPM-IT5. To update the firmware, open your favourite web browser (we recommend Mozilla Firefox).Type this IP address into the address bar.
  • Page 11: Function Libraries

    This function allows a third party device to control the PPM-IT5. External Variable This really interesting function is used if you want to show on the PPM-IT5 touchscreen the status of a non-Terracom device. How to use the function libraries...
  • Page 12 Macro - Go in the page : Setup 1 -> function libraries -> Macro. - Create a new macro: Add / give a name to the macro. You can add commands to the macro. This means that you will start these commands when you select a macro…...
  • Page 13 Command (String) This function is used to send an ASCII command to a 3 party device. Write in the string combo, the ASCII command you will sent to the 3 party device. 2 different modes: Time interval: number of time you will repeat the string and at what interval Time Out: When the IT5 will send commands to the 3 party device, the device needs to respond(+Ans) within the set time(+Time Out ?? ms), or repeat sending, send the...
  • Page 14 MODE_ZERO means that the logic output will be set to zero MODE_ZERO means that the logic output will be set to zero MODE_ONE means that the logic output will be set to MODE_ONE means that the logic output will be set to one MODE_TOGGLE means that the logic output will be set to MODE_TOGGLE means that the logic output will be set to zero if it was on one, and to zero if it was on one, and to...
  • Page 15 Function: Call:call one device or call devices one by one several dev vice or call devices one by one several devices. Paging:paging to device.(one or more) paging to device.(one or more) Message:playing message to device..(one or more) playing message to device..(one or more) Monitor:...
  • Page 16 ______, under line is function's name. External Variable IT5 can display the status of a non IT5 can display the status of a non-Ateis device. ※ AMP mean amplifier device, not terra com amplifier device, not terra com-AMP device...
  • Page 17 Other device For example: AMP on/off Zone selected selected External variable=>Other device send string (3rd party control for example) to IT5 via ethernet, than IT5 show the AMP on/off status on its screen. External variable There are two ways to know the device status: to know the device status: •...
  • Page 18 Step 2 Add the command string, set for trigger “ask manual Add the command string, set for trigger “ask manually” button to other device ly” button to other device Send command string device's IP Send command string device's IP and port info Add the external Add the external variable...
  • Page 19 Step 3 Add locked button: for display the status of other device Add locked button: for display the status of other device Add the test variable Step 4 Main window setting: The button of IT5 screen Main window setting: The button of IT5 screen This button is display the answer of the device status This button is display the answer of the device status This button is for ask other...
  • Page 20 Step 5 This UDP software is LAB test software and mean the other device This UDP software is LAB test software and mean the other device This UDP software is LAB test software and mean the other device above document(AMP-amplifier) When in IT5 screen trigger "ask asp status"...
  • Page 21 ● Ask automatically ==>The set process is the same step 1,2,5 ==>The set process is the same step 1,2,5 Step 1 need to set “Auto Update(4s)”, automatically detect the item”ask amp satus” Step 1 need to set “Auto Update(4s)”, automatically detect the item”ask amp satus” Step 1 need to set “Auto Update(4s)”, automatically detect the item”ask amp satus”...
  • Page 22 Need to reply Need to reply 1 or 0 state 1 or 0 state manually manually UDP software will received inquiry string UDP software will received inquiry string automatically from IT5 This button is display the This button is display the answer of the device status the device status...
  • Page 23: Audio Format

    The IP address of the device is written on the touchscreen. Add a prerecorded message into the PPM-IT5 Into the PPM-IT5, there is 68Mo memory to add .wav files used as prerecorded messages. To add a message into the device, go to:...
  • Page 24: Change The Chime

    You can dial for the ECS with the PPM-IT5. Please check the ECS manual to know the settings in the Ateis Studio Software. The only thing you have to set up in the PPM-IT5 itself Setup 1 -> basic settings -> dial agent -> agent service -> enable.
  • Page 26: On The Ppm-It5 Side

    All the audio codec’s can be used Check if the gain of the microphone on the PPM-IT5 is high enough and press save. Click on the device list. If the UAPG2 is programmed correctly it will be shown in the realtime Search window.
  • Page 27 In this window, you will set up the zones that you will access on the UAP. Up to 16 zones can be selected on the UAP. The name of the function is the label written on the button which will appear on the PPM-IT5 touchscreen.
  • Page 28 To add a function to a button in the main window add a button and select in the prior button function button name divice and the name of the button in the pulldown menu. Make a paging group (more than one divice with different IP addresses)
  • Page 29 Result Now there are 3 buttons on the PPM-IT5 touchscreen with one of the buttons as all call. Done...
  • Page 30 Be careful, all theses settings must be exactly the same in the IT5. The server settings are necessary if you use a SIP server. In the contact manager, add the PPM-IT5 (name + IP address). Again the name must be the exactly name given in the IT5’s webpage.
  • Page 31 You can call the IT5… but first set up the PPM-IT5 On the PPM-IT5 side: First add in the Address Book the IDA8.