INSTALLATION AN SERVICING INSTRUCTIONS THE FOLLOWING SECTION
LISTS THE INSTALLATION REGULATIONS AND REQUIREMENTS
All gas appliances must be installed by a competent person in accordance with the current Gas Safety (Installation
failure to do so could lead to prosecution
The following are the relevant Codes of Practice and British Standards.
BS 8303 1986
BS1251 1987
BS 6891 1988
BS 715 1989
BS 7566 Pts 1-4
BS 5440 Ptl 1990 & Pt2 1989The Building Regulations issued by the
BS 5871 Pt2 1991 & Pt3 1991 Department of the Environment. The
BS 6461 Ptl 1984
Building Standards Scotland)(Consolidation)
BS 1289 Ptl 1986
Regulations issued by the Scottish Development
1992
Department.
TECHNICAL DATA
Overall height of fire
Minimum height of opening required
Maximum height of opening
Minimum width of opening required
Maximum width of opening with spacer
Forward projection from opening
(With controls cover)
Min depth of openings
TYPE OF GAS G20 Only
GAS INPUTS (Gross)
Main Injector Type
= 614 mm
= 590 mm
= 395 mm
= 470 mm
See Figs 1-8
Supply Pressure 20 mbar +/- lmbar (Cold)
Maximum 5.42 kW (18500 Btu/h)
Minimum 2.34 kW (8000 Btu/h)
Pilot 0.26 kW (890 Btu/h)
Bray Cat 82/380
Or Stereomatic 046/19/196/68M
SIT Oxy/Pilot NG 9022
GAS CONNECTION
8 mm O/D Tube
WEIGHT
22 kg
Note: None of the materials used in the manufacture of this appliance contain asbestos.
INSTALLATION NOTES
Care should be taken to ensure when the appliance is installed into a Pre-cast flue, the chimney breast is lined to
prevent the plaster etc, cracking through excessive temperatures.
due to the temperatures produced in the fire bed.
A hearth must always be provided, a minimum of 340mm and a minimum of 150mm either side of the fire opening
etc, being placed on the hearth.
The area under the firebox must have a minimum non-combustible thickness of 25mm.