P4DMS Excalibur Calibration Procedure (Main board FCS
P4DMS_EX_029_24)
Initial unity level setting:
1- Set Ratio, Threshold and Gain to zero and Blend to 100%
wet on both channels.
2- Set timing to RMS being sure no other timing switch is
engaged.
3- Make sure Feedback and External SC are not engaged.
4- Put compressor in SE I/O mode on both channels.
5- Apply a 0 dB / 1 kHz tone to the left TS input.
6- Measure the signal at the left TS output connector.
7- Adjust the Gain trim (R105) at the left VCA section so output
matches input.
8- Repeat for right channel using Gain trim (R101).
Balanced output unity level calibration:
1- Set Ratio, Threshold and Gain to zero on both channels.
2- Set timing to RMS being sure no other timing switch is
engaged.
3- Make sure Feedback and External SC are not engaged.
4- Make sure compressor is not in SE I/O mode.
5- Apply a +4 dB / 1 kHz tone to the left XLR input.
6- Measure the signal at the left XLR output connector.
7- Adjust the Gain trim at the left balanced I/O section located
in the left side of the compressor so output matches input.
The left gain trim is closest to the front panel.
8- Repeat for right channel using the gain trim closest to the
rear panel.