Digital blood pressure monitoring system

Advertisement

Digital Blood Pressure Monitoring System
Model: BP - 811
INSTRUCTION MANUAL
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the COMPACT BP-811 and is the answer not in the manual?

Questions and answers

Summary of Contents for Priva COMPACT BP-811

  • Page 1 Digital Blood Pressure Monitoring System Model: BP - 811 INSTRUCTION MANUAL...
  • Page 2 Thank you for purchasing the PRIVA Compact Digital Blood Pressure Monitoring System. This manual provides important information to assist you in the use of the device. Please read the instruction manual thoroughly before using this product. If you have any additional questions regarding this product, please contact the place of purchase or Homemed (Pty) Ltd customer service on 0861 106 150.
  • Page 3 COMPONENTS OF THE BLOOD PRESSURE MONITOR The illustration shows the upper arm blood pressure monitor, consisting of: Cuff Display TIME POWER MEMORY Button Button Button Time and Date Systolic Reading The User (SYS.) Memory Irregular Heart Rate Diastolic Reading (DIA.) Low Battery Indicator Pulse...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS 1. Understanding Blood Pressure 2. Monitor Set-Up 3. Performing a Measurement 4. Memory Storage and Recall 5. Care and Maintenance 6. System Troubleshooting 7. Technical Specifications...
  • Page 5: Understanding Blood Pressure

    1. UNDERSTANDING BLOOD PRESSURE Blood pressure readings are reported as two values (numbers). The top value (number) is the maximum pressure the heart exerts while beating (systolic pressure). The bottom value (number) is the amount of pressure in the arteries between beats (diastolic pressure).
  • Page 6: Monitor Set-Up

    2. MONITOR SET-UP 2.1. Inserting the Batteries After you have unpacked your device, first insert batteries. • Remove battery cover located on the bottom of the monitor. • Insert batteries (4× 1.5V AAA), observing the indicated polarity. 2.2. User Selection This advanced blood pressure monitor allows you to track blood pressure readings for 2 individuals, independently.
  • Page 7: Performing A Measurement

    Once all of the settings have been completed, press the “TIME” button again. The date and time is briefly displayed and all of the settings have been confirmed. 3. PERFORMING A MEASUREMENT 3.1. Before the Measurement • Several factors may influence the blood pressure measurement result such as exercise and caffeine (coffee, tea, energy drinks).
  • Page 8 3.3. Taking a Measurement • Ensure the correct user is selected before starting the measurement. • Press the “POWER” button. The cuff will inflate. • Once the inflation pressure is reached, the pump pressure slowly diminishes. The cuff pressure (large characters) is displayed during the measurement.
  • Page 9: Memory Storage And Recall

    4. MEMORY STORAGE AND RECALL 4.1. Memory Capacity • The blood pressure monitor automatically stores the last 120 measurement values, for two individual users. • Once the memory capacity is reached, the oldest values are automatically superceded. 4.2. Memory Recall: Average of Last 3 Measurements By pressing the “MEMORY”...
  • Page 10: Care And Maintenance

    4.4. Date and Time With the device switched off, press the “TIME” button. The current date and time will be displayed. The device switches off automatically after 150 seconds. 5. CARE AND MAINTENANCE 5.1. Caring for Your Meter • Use the device according to the instructions contained in this user manual.
  • Page 11 discontinued and a corresponding error code is displayed. Error Code Illustration Possible cause(s) Err 2 Can’t detect the pulse. The inflation time is too long, the cuff Err 4 is not worn properly or the tube has been disconnected. The measurement result is invalid. Err 5 Please measure again.
  • Page 12: Technical Specifications

    7. TECHNICAL SPECIFICATIONS Measurement principle: Oscillometric method Display: Digital Measuring range: Blood Pressure: 0 to 260 mmHg ( in 1 mmHg increments) Pulse: 40 to 200 beats/minute Accuracy: Blood Pressure: ±3mmHg Pulse: ±5% of reading Inflation: Automatic inflation by internal pump Inflation setting: Auto inflation (140-250 mmHg) Memory function:...
  • Page 13 Explanation of marks and symbols The following marks and symbols may appear in the manual, on the electronic blood pressure monitor and its packaging. Refer to instructions manual/booklet. IMPLICATION OF SYMBOL Type-BF applied part. CE Mark:conforms to essential requirements of the Medical Device Directive 93/42/EEC.
  • Page 14 Authorised distributor: Homemed (Pty) Ltd, Co Reg 2003/022932/07 Route 21 Corporate Park, 100 Sovereign Dr, Irene, 0157, South Africa T: 0861 106 150, W: www.homemed.co.za, E: sales@homemed.co.za StrongStar Room 301, Buiding 1, No.10, Gangjian Road Changping Town, Dongguan City, Guangdong Province, China T: +86-21-57753176, E: sales@ss-med.com W: www.ss-med.com Shanghai International Holding Corporation GmbH (Europe)