Quick Links

INTRODUCTION
This manual provides instructions for identification,
installation, operation, and technical assistance for
the Valcom V-9923B Code Call Unit.
The V-9923B provides two or three digit code call
paging via a loop start trunk port on a PABX or by
the use of a spare line button on a key system.
The V-9923B code call unit complies with Part 68 of
the FCC Rules and Regulations and has been granted
FCC Registration #BAFUSA-68753-KX-N. The
ringer equivalence is 0.1B and the unit requires a
USOC RJ21X connector.
In accordance with FCC Rules and applicable tariffs,
this code call unit may only be installed with the
authorization of the owner of the host system.
The FCC Registration #BAFUSA-68753-KX-N, will
be listed in the affidavits filed with the telephone
company; it will also be recorded in the system log
kept by installation and maintenance personnel. The
local telephone company is to be notified of the FCC
registration number when this code call unit is
installed.

SPECIFICATIONS

The V-9923B is capable of providing code signaling
for paging purposes; it provides for "meet me"
answer of code call and provides talk circuit and
signaling tone.
Features
Trunk level access on PABX's, station level
answer
Can be used with 1A2 type key systems
81 two digit codes or 729 three digit codes
Uses rotary or tone dial signaling
Table 1
Range
Idle
"A" Battery
–21.5 to –26 Vdc
V-9923B
CODE CALL UNIT
Operating
65mA
Dial tone to calling party
Coded tone output for paging systems
Switch controlled code verification tone
Automatically discontinues code sending when
answered
Capable of being used with another V-9923B to
provide two link operation
Uses standard 1A2 key system voltages
Mounts on the wall, in a key cabinet, or in the
PABX Cabinet
Capacity
Each V-9923B Code Call Unit provides the necessary
equipment for 1 link of code call. For an additional
link of code call, another V-9923B is required (two
links maximum).
Dimensions
7.1"H x 5.9"W x 2.1"D
(18.03cm H x 14.99cm W x 5.33cm D)

Power Requirements

The Valcom V-9923B requires –24 Vdc talk
battery and –24 Vdc signal battery. The current
consumption and voltage range is shown in Table 1.
"B" Battery
–21.5 to –26 Vdc 125mA
Nominal Timing and Frequency
1
VSP-V-9923B
Issue 4
947923

Advertisement

Table of Contents
loading

Summary of Contents for Valcom V-9923B

  • Page 1: Specifications

    7.1"H x 5.9"W x 2.1"D (18.03cm H x 14.99cm W x 5.33cm D) Power Requirements The Valcom V-9923B requires –24 Vdc talk battery and –24 Vdc signal battery. The current consumption and voltage range is shown in Table 1. "B" Battery...
  • Page 2 Specifications The timing and frequency specifications of the Valcom V-9923B code call unit are shown in Table 2. Figure 1 is a timing chart showing the nominal timing of a code call. Table 2 Dial Tone Frequency Coded Tone Frequency...
  • Page 3: Installation

    Use twisted pair wire for all connections. Mounting The Valcom V-9923B code call unit may be mounted in a key cabinet relay rack or on the wall near the distribution frame. When choosing a location, it is necessary that the loop resistance of the PABX or key system are not exceeded.
  • Page 4: Operation

    Call (540) 563-2000 and ask for Technical Support, or call (540) 427-6000 for Valcom 24-hour Automated Support or visit our website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom, Inc.
  • Page 5: Troubleshooting Chart

    (Major repairs will be subject to additional charges for parts and labor). This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damage, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product.
  • Page 6 W/BL PBX AND BL/W KEY SYSTEM INPUT W/BR ANALOG PBX ANSWER PORT BR/W R/BL BL/R R/BR BR/R SWITCHED BK/BL RELAY BL/BK OUTPUT BK/O O/BK BK/G G/BK BK/BR BR/BK BK/S TONE S/BK OUTPUT Y/BL BL/Y Y/BR BR/Y V/BL BL/V EXPANSION CIRCUIT V/BR BR/V POWER...
  • Page 7 PART OF PBX LOOP START OUTGOING C.O. TRUNK (ROTARY OR T.T.) PBX ANALOG STATION PORT FIGURE 4 CONNECTIONS OF V-9923B TO PABX PART OF KEY TELEPHONE INSTRUMENT P.U. H.S. TO REST OF KEY STRIP FIGURE 5 CONNECTION OF V-9923B TO KEY SYSTEM 10 Vac NOTE 1 NOTE 2...
  • Page 8 Diode 1N4003 or eq. BK/BL BL/BK Relay Coil (Portion of Connecting Block) DC Power Supply depends on relay requirements FIGURE 7 CONNECTIONS OF V-9923B FOR OPERATING A DC SLAVE RELAY TO PBX TRUNK OR SPARE LINE BUTTON ON TELEPHONE (ACCESS) BATTERY FEED TONE OR ROTARY...