Wiring:
We
recommend
wiring
with
two-conductor
shielded
cable
(such
as
Belden
8451
or
equivalent)
because
signal
current
flows
through
the
two
conductors
only.
The
shield
does not carry
signal,
is
used only
for shielding,
and
is
ordinarily
connected
to
ground
at
one end
only.
The
following
table
and diagram
are applicable
to
a great
majority
of installations.
If
you
wish
to
use
single-conductor shielded
cable,
see
the
section
immediately
below.
0»T
~l
fBAtANCCO)
I
OUT
<
I
(UN
8
A
1
.ANCED)|
Him
Mm
I
ORBAN
UM\T
i
1
»
\\
J
1
1
3
7 ?
o
1
1
DRIVEN
EQUIPMENT
^
IF
ORftAM UMVt
(S
COUIPPED WITH
OPtlONAL OUTPUT TPANSTORMCR,
TWIN
INSTALL
THIS
JUMPSR.
Fig. B-4:
GROUNDING
TABLE
1:
GENERAL
INPUT/OUTPUT
CONNECTION RULES
INPUT
1)
Always
use
(+)
and
(-)
as
the
two
input
terminals
to
the
414A.
2)
When
the
414A
is
driven
from
an
unbalanced
source,
connect
the
shield to
circuit
ground
at
the source and
to chassis
ground
at
the
414A. Connect
the
(-)
input
to
chassis
ground
as well.
3)
When
the
414A
is
driven
from
a
balanced
source,
connect
shield at
the
source
end
to
chassis
ground.
Do
not
connect
shield
at
414A
end.
OUTPUT
1)
At
the
414A
output,
connect
the shield
at
the
414A
end
to
chassis
ground
(whether
driving
balanced
or
unbalanced
loads).
Do
not
connect
the
shield
at
the other end.
2)
When
driving
an unbalanced
load,
connect
the
circuit
ground
of the
driven
equipment
to
the
414A's
(-)
output.
Connect
the hot side
of the
driven
equipment's
input to the
414A's
(+)
output.
3)
When
driving a
balanced
load,
jumper
the
circuit
ground
to
the
chassis
ground on
the
414A
(on
rear
panel).
When
driving
an unbalanced
load,
do
not
use
this
jumper.