HOR
Pin No.
Symbol
Description
1
VAREF
Analog reference voltage for A/D conversion
2
VASS
Analog reference GND for A/D conversion
3
KEY
Input Selector, Power key input terminal.
:
To read Input Selector and Power key by means of A/D conversion
4
INPUT
Muting output terminal for Main amplifier input. Active "H"
Mating output terminal for Rec. output. Active "H™
5
RECMUT
To be output when switching Input Selector.
To be output continuously in case of Input Selector TAPE-1, TAPE-2, DAT, and DIGITAL-4.
Control output terminal for PLAYER.
6
PLAYER
"L" will be output for 200ms if input K64 code for remote control and set Input Selector for
PHONO.
7
VOL DOWN
UP/DOWN output terminal for volume. Active "H"
In case of UP (DOWN), VOL UP outpout will be "H" ("L"), while VOL DOWN output will be "L"
8
VOL UP
CH").
When not moving, both outputs shail be "H" (Brake).
9
SEL DOWN
UP/DOWN output terminal for Input Selector. Active "H" In case of UP (DOWN), SEL UP output
will be "H" ("L"), While SEL DOWN output will be "L" ("H").
10
SEL UP
When not moving, both outputs shall be "H" (Brake).
Wl
Sl
Output terminal for switching digital signal.
12
S2
Switch as follows through the position of Input Selector.
13
83
Input
3
2
éeletor
Output S.
Output S:
Output SI
DIGITAL-1
ti
L
L
DIGITAL-2
L
L
H
DIGITAL-3
L
H
L
DIGITAL-4
L
H
H
Others
(Analog)
H
Ht
e
14
EXP/JPN
Input terminal for remote control initialization when energizing.
Need help?