Zemic BM24L10 Series Installation And Operation Manual

Hygienic load cell

Advertisement

Quick Links

Type BM24L10 EHEDG Load Cell
BM24L10 Series Hygienic Load Cell
Installation and Operation Manual
Zemic Europe B.V.
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.
T: +31 76 50 39480
info@zemic.nl
Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1
www.zemiceurope.com

Advertisement

Table of Contents
loading

Summary of Contents for Zemic BM24L10 Series

  • Page 1 Type BM24L10 EHEDG Load Cell BM24L10 Series Hygienic Load Cell Installation and Operation Manual Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1...
  • Page 2: Table Of Contents

    5 Technical Specifications ......................6 6 Overall Dimensions .......................7 Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1...
  • Page 3: Safety Instructions

    Type BM24L10 EHEDG Load Cell 1 Safety Instructions 1.1 Specific Condition of Use The BM24L10 series weighing sensors are suitable for technical weighing applications within the specified environment and measuring range, and are not suitable for any purpose beyond the specified range.
  • Page 4: General Risk Of Non-Compliance With Safety Instructions

    For design and safety reasons, users are prohibited any change or modification to the sensor unless expressly approved by ZEMIC. We are not responsible for any loss caused by any change or modification without permission. Any modification without permission immediately voids warranty.
  • Page 5: Pre-Cautions

    Fix the bottom of the sensor on the mounting hole, and apply the load from the top. ZEMIC provides a round sealing ring for sealing the gap between the lower end of the sensor and the customer's bottom mounting plate to prevent microbial contamination.
  • Page 6: Cleaning

    Figure 3-1 is the schematic diagram of using low pressure clean water for cleaning: Water hose Figure 3-1 Cleaning by pressure clean water Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl...
  • Page 7: Electrical Connection

    Input (-) Brown Output (+) White Output (-) Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1 www.zemiceurope.com...
  • Page 8: Pre-Cautions

    (AISI 630) Stainless Steel 17-4PH Sealing Ring & Sheath Material Silicone Rubber RH200-50 Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1 www.zemiceurope.com...
  • Page 9: Overall Dimensions

    Front View Top View Bottom View Figure 6-2 Sensor Size Diagram Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1 www.zemiceurope.com...