Specifications; Troubleshooting - Kogan P2 PRO User Manual

Pet grooming kit & vacuum
Table of Contents

Advertisement

SPECIFICATIONS

Voltage/Frequency
Motor current load
Heating current load
Dust cup capacity

TROUBLESHOOTING

Fault
The appliance will
not operate
Weakened suction
There is an
abnormal noise
during operation
Appliance suddenly
stops
220V – 240V ~ 50Hz
1.5A
0.3A
4L
Possible causes
Check whether the plug is
firmly inserted into the
outlet.
Check whether the power
outlet has electricity.
Check whether the
appliance has been turned
on.
Check whether the filter
element is blocked.
Check whether the dust
cup is full.
Check whether the filter
element is blocked
The power cord has been
accidentally removed.
The dust cup is full or the
air outlet is blocked,
causing the motor to
overheat.
Solution
Reinsert the power plug
into the outlet.
Test the power outlet with
a different appliance.
Ensure the power outlet
has been turned on.
Empty the dust cup and
clean the filter.
Remove any blockages.
If there is still abnormal
noise, cease use and
contact help.Kogan.com
for support.
Reinsert the power cord
plug.
Turn off the power switch,
clean up the dust cup
garbage and wait 30
minutes before turning it
on.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kavapetv02p

Table of Contents