Process Pressure Transmitters PTPi and PTDi
Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
1
2
2
2
2
3
4
4
4
5
1.
7
• The manual is aimed at specialists and semi-skilled
8
personnel.
8
• Please read the instructions carefully before carry-
ing out any operation and keep the specified order.
8
9
• Thoroughly read and understand the information in
9
chapter 2 "Safety Instructions".
9
If you have any problems or questions, please contact
9
your supplier or contact us directly at:
9
9
10
10
10
ARMANO Messtechnik GmbH
10
Location Beierfeld
10
Am Gewerbepark 9 • 08344 Grünhain-Beierfeld
11
Tel.: +49 3774 58 - 0 • Fax: +49 3774 58 - 545
11
11
mail@armano-beierfeld.com
11
Location Wesel
12
Manometerstraße 5 • 46487 Wesel-Ginderich
12
Tel.: +49 2803 9130 - 0 • Fax: +49 2803 1035
12
mail@armano-wesel.com
12
www.armano-messtechnik.com

Information on This Operating Instruction

B09-711
10/23
12
13
19
20
21
22
32

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PTPi and is the answer not in the manual?

Questions and answers

Summary of Contents for ARMANO PTPi

  • Page 1: Table Of Contents

    B09-711 Operating Instructions Process Pressure Transmitters PTPi and PTDi 10/23 Contents Information on This Operating Instruction 9.1 Set Range, Nominal Measuring Range, 1.1 Pictographs Used Definitions 1.2 Exclusion of Liability 9.2 Configuration and Calibration 1.3 General Information 9.3 Alarms Safety Instructions 10.
  • Page 2: Pictographs Used

    The process transmitter models PTPi and PTDi are IMPORTANT! Is used to warn you against manufactured in accordance with the corresponding a possibly hazardous situation that may re- valid standards.
  • Page 3: Device Description

    • Only use appropriate tools for mounting, connect- The nameplates of the PTPi and PTDi ing and dismounting the device. transmitters in versions compliant with • Nameplates or other information on the device shall...
  • Page 4: Intended Use

    Usup[V] = Umin[V] + 0.0225 [A] x Ro[Ω] In a 2-wire system, the PTPi and PTDi transmitters whereas: Rmax = maximum permissible load generate a 4…20 mA output signal with superim- resistance for a specific voltage posed HART signal.
  • Page 5: Ptpi - Pressure Ranges And Metrological Parameters

    Operating Instructions Process Pressure Transmitters PTPi and PTDi Degree of protection Permissible ambient conditions IP66, 67 according to DIN EN 60529 Ambient temperature IP65 according to DIN EN 60529 −40 / +85 °C with PD plug connector (for PED version in accordance with metrological...
  • Page 6 1/2" NPT. Metrological parameters according to PED version The limitation does not apply to the PTPi transmitters in the versions according to the female threads G 1/4". pressure equipment directive PED can be manufac- tured with a pressure range from −1 / +400 bar vacu- um and overpressure, 0 –...
  • Page 7: Ptdi - Pressure Ranges And Metrological Parameters

    Operating Instructions Process Pressure Transmitters PTPi and PTDi PTDi – Pressure Ranges and Metrological Parameters Pressure ranges Turn- Max. Max. Nominal measuring range (FSO) Minimum set range down overpressure static pressure – – 10:1 – – 1.6 MPa 0.16 bar 10:1 –...
  • Page 8: Ptpi, Ptdi - Environmental Parameters

    Operating Instructions Process Pressure Transmitters PTPi and PTDi Process connections Climatic immunity PTDi connection type C for mounting with a manifold Temperature: (fig. 9), available for PED version. EN 60068-2-1, EN 60068-2-2 PTDi with single direct chemical seal as in the exam- hot: T = 55 °C, RH = max.
  • Page 9: Pressure Transmitter Housing

    Place of Installation Pressure Transmitter Housing General Recommendations The cases of PTPi, PTDi pressure transmitters are made of die-cast aluminum or stainless steel and The intelligent pressure and differential pressure consist of a body and two screw covers (display and transmitters can be installed both indoors and out- electrical connection).
  • Page 10: Low Ambient Temperature

    High Medium Temperature Installation and Mechanical Connections With the PTPi, PTDi transmitters, media with temper- atures up to 120 °C can be measured (PED version  chapter 4 “Technical Data”). To protect the sensor module from temperatures higher than 120 °C, long impulse lines are used to...
  • Page 11: Ptpi Installation And Connections

    PTPi Installation and Connections When disassembling the pressure trans- mitter, it is necessary to separate it from The PTPi transmitters can be mounted directly on rig- the process pressure or to reduce the id impulse lines. pressure to atmospheric level and to...
  • Page 12: Electrical Connections For Ptpi, Ptdi

    2a and 2b. If the resistance rating liquid or when PTPi, PTDi transmitters are used in the current loop is smaller than 240 Ω, with chemical seals and capillary line.
  • Page 13: Configuration And Calibration

    Operating Instructions Process Pressure Transmitters PTPi and PTDi Configuration and Calibration Transmitter configuration using the buttons on the device and the local menu The pressure transmitter has functions for setting and changing metrological and identification param- Local menu structure. Local configuration of the eters.
  • Page 14 Operating Instructions Process Pressure Transmitters PTPi and PTDi The menu structure of the PTPi and PTDi is shown below: The selected unit should be confirmed by pressing the button []. After confirming the parameter, the pressure transmitter confirms acceptance of the command with the mes- sage “DONE”...
  • Page 15 Operating Instructions Process Pressure Transmitters PTPi and PTDi Descriptions: Local Menu Submenu Information EXIT return from the local menu to normal operation of the pressure transmitter PVZERO pressure zero adjustment set the lower measuring value (no change of the measuring range)
  • Page 16 “−” sign. The position of the decimal point can be set in the local menu, via HART commu- ERR_L16 nicator or PC configuration software. The PTPi, PTDi [acces_restricted] This error occurs when the local transmitters allow the re-scaling of the pressure val- menu of the pressure transmitter is disabled and the ues to user specific units.
  • Page 17 Operating Instructions Process Pressure Transmitters PTPi and PTDi The local display is equipped with a background lighting. Configuration of the PTDi pressure transmitter for flow measurement with an orifice plate Figure 4 shows how to change the display position by rotation.
  • Page 18 Operating Instructions Process Pressure Transmitters PTPi and PTDi Orifice flow meters are based on the square root out- put signal of the differential pressure transmitters. For flow measurement, you should: Æ install the PTDi pressure transmitter on the flow measurement station with orifice plate;...
  • Page 19: Alarms

    Operating Instructions Process Pressure Transmitters PTPi and PTDi Alarms The pressure transmitters PTPi generate a pro- cess variable analogue signal range The alarms indicate if operating parameters of the ≥ 3.8 – 3.9 mA…≤ 20.5 mA. Depending on the set-...
  • Page 20: Maintenance / Cleaning, Storage And Transport

    Operating Instructions Process Pressure Transmitters PTPi and PTDi Maintenance / Cleaning, Cleaning: Storage and Transport • Clean the device with a dry or slightly dampened soft cloth. CAUTION! Material damage and loss of • Do not use any sharp objects or aggressive agents warranty! for cleaning.
  • Page 21: Ce Conformity

    Operating Instructions Process Pressure Transmitters PTPi and PTDi CE Conformity Dismounting: Æ Pay attention to potentially leaking media. Take ap- propriate precautions to collect them. The CE marking of the instruments certifies Æ Please clean the process connection before at- the conformity with prevailing EU directives taching the protection cap.
  • Page 22: Figures

    PTPi, PTDi pressure transmitters Fig. 3 PTPi pressure transmitter Fig. 4 PTPi, PTDi – display rotation option, configuration buttons Fig. 5 plug connector M-type with thread M 20x1.5 Fig. 6 plug connector P-type with thread M 20x1.5 Fig.
  • Page 23 Process Pressure Transmitters PTPi and PTDi Fig. 2 electrical connections for PTPi, PTDi pressure transmitters Fig. 2a the connection of the pressure transmitter and communicator to the control cabinet for power supply (if the resistance in the current loop is higher than 240 Ω)
  • Page 24 Operating Instructions Process Pressure Transmitters PTPi and PTDi Fig. 2c the connection of the pressure transmitter and communicator to the <SIGNAL+><TEST+> transmitter terminals if the resistance in the current loop is smaller than 240 Ω Fig. 2d the connection of the pressure transmitter and communicator to the <SIGNAL+><SIGNAL−> transmitter terminals if the resistance in the current loop is smaller than 240 Ω...
  • Page 25 Operating Instructions Process Pressure Transmitters PTPi and PTDi Fig. 3 PTPi pressure transmitter Fig. 4 PTPi, PTDi – display rotation option, configuration buttons www.armano-messtechnik.com • p. 25 of 32 • GB • 10/23 • B73 • B09-711...
  • Page 26 Operating Instructions Process Pressure Transmitters PTPi and PTDi Fig. 5a connection M-type with thread M 20x1.5 Fig. 5b socket for M-type plug connector Fig. 6a connection P-type with thread M 20x1.5 Fig. 6b socket for P-type plug connector Fig. 7a CM 30x2 plug connector Fig.
  • Page 27 Operating Instructions Process Pressure Transmitters PTPi and PTDi Fig. 8a connection G 1/2 with thread G 1/2" Fig. 8b socket for connection G 1/2 Fig. 8c connection CG 1/2 Fig. 8d socket for connection CG 1/2 with flush welded membrane order code socket –...
  • Page 28 Operating Instructions Process Pressure Transmitters PTPi and PTDi Fig. 9 differential pressure transmitter PTDi with process connection type C S-T type tube flange chemical seal S-P type flush flange chemical seal Fig. 10 example: differential pressure transmitter PTDi with a chemical seal...
  • Page 29 Operating Instructions Process Pressure Transmitters PTPi and PTDi mounting kit (“bracket Ø 25”) for fitting differential pressure transmitters with P-type connection on a Ø 25 pipe Fig. 11 example: installation of the PTDi pressure transmitter with external membrane bracket C2 for fitting differential pressure transmitters with C-type connection on a 2"...
  • Page 30 C2 for fitting differential pressure transmitters with a manifold on a 2" pipe Fig. 13 example: mounting PTDi pressure transmitters with a manifold on a 2" pipe tube mounting wall mounting Fig. 14 example: mounting PTPi, PTDi pressure transmitters B09-711 • B73 • 10/23 • GB • p. 30 of 32 • www.armano-messtechnik.com...
  • Page 31 Operating Instructions Process Pressure Transmitters PTPi and PTDi Close the cover tightly by loosening the screw Fig. 15 sealing the housing of PTPi, PTDi pressure transmitters Fig. 16 additional equipment for the installation of pressure transmitters www.armano-messtechnik.com • p. 31 of 32 • GB • 10/23 • B73 • B09-711...
  • Page 32: Declaration Of Conformity

    Tel.: +49 2803 9130 – 0 Bernd Vetter Fax: +49 3774 58 – 545 Fax: +49 2803 1035 Geschäftsführender Gesellschafter / Managing Director mail@armano-beierfeld.com mail@armano-wesel.com www.armano-messtechnik.de © 2023 ARMANO Messtechnik GmbH · Technical changes, replacement of materials and printing errors excepted! www.armano-messtechnik.com...