Page 1
INSTRUCTION MANUAL UV-22Viewer UV-22 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan https://www.rion.co.jp/english/...
Page 3
FOR SAFETY In this manual, important safety instructions are specially marked as shown below. To prevent the risk of injury to persons and severe damage to the unit or peripheral equipment, make sure that all instructions are fully understood and observed. Caution Disregarding instructions print- ed here incurs the risk of injury...
Page 4
Caution Do not play the disc in a CD player! The CD-ROM containing this software is not a music CD. Inserting the disc in a CD player poses the risk of excessive volume levels that can cause hearing damage and damage to the CD player. Important About the Microsoft Windows operating system This manual does not provide general information on how to use the...
Article 1 Authorized Use This Software (including updated or customized versions) is designed for use with the interface unit UV-22 (hereinafter “the Product”). You are authorized to use the Software only in conjunction with the Product, in such a way as stipulated in this Agreement.
Page 6
Product, even if this is due to a defect or other problem with the Software. 3. In no event does RION assume liability for any kind of direct or indirect damage, loss of profi t or anticipated gain, or any other damage caused by the use of the Software, or the inability to use the Software.
Page 7
Article 7 Third Party Benefi ciaries This Software includes components for which the rights are held by other parties except RION. In the case of a violation of this Agreement, in addition to RION, such third parties shall also have the right to demand compensation...
Contents Software Usage License Agreement ..........iii Outline ....................1 Preparations ..................3 Installation ..................4 Connections ..................9 Connections for USB link ............9 Connections for LAN link ..........10 Starting the Application ..............12 Startup screen ..............12 Timeout setting screen ............15 LAN Setting screen ............16 Instantaneous value display and setup screen ....
UV-15 Input user fi lter values for linked UN-14/UV-15 Operation control: The software supports control of one UV-22 unit. Via the UV-22 unit, the software can control up to 16 UN-14 and UV-15 units. Precautions • Suitable ID numbers must have been assigned to UN-14 and UV-15 units linked to the UV-22.
Page 10
Outline Operating environment Supported operating systems: Microsoft Windows 8.1 Pro (32 bit/64 bit) Microsoft Windows 10 Pro (32 bit/64 bit) CPU: Intel (R) Celeron (TM) processor 800 MHz or higher RAM: 256 MB or more...
For 32 bit Microsoft Windows 8.1 Pro/10 Pro installer_x64: For 64 bit Microsoft Windows 8.1 Pro/10 Pro vb_sample folder Contains sample software for retrieving data from the UV-22 using the DOD command. The software is written in Visual Basic.
Installation Install the USB driver on the computer as follows. 1. Start up the computer. Close any other software that is running. When using 32 bit OS, execute the fi le “setup.exe” located in the “installer_x86” folder. When using 64 bit OS, execute the fi le “setup.exe” located in the “installer_x64”...
Page 13
Installation Follow the wizard to complete the installation. Screens during installation are as follows.
Page 14
Installation Depending on your environment, [Windows Security] may be dis- played. Click on “Install” or “Continue”.
Page 15
Installation 2. Make sure that the POWER switch of the UV-22 is set to OFF and that the communication function selector on the front panel is set to USB. 3. Plug the USB cable into the USB port of the UV-22 and plug the other end of the cable into the USB port of the computer.
Page 16
Installation When the computer detects the UV-22, the device driver software installation is started automatically. When the installation has been completed, USB communication is enabled.
If the Battery Unit BP-17 is part of the system, connect the AC adapter to the BP-17. In this case, leave the POWER switch of the UV-22 constantly set to ON. Sound Level Meter Unit UN-14 or Interface Unit UV-22 Vibration Meter Unit UV-15 (max.
If the Battery Unit BP-17 is part of the system, connect the AC adapter to the BP-17. In this case, leave the POWER switch of the UV-22 constantly set to ON. Sound Level Meter Unit UN-14 or Vibration Meter Unit UV-15 Interface Unit UV-22 (max.
Page 19
Connections Important Use only the optional AC adapter NC-99 series. Using any other AC adapter can result in mal- function and damage.
The startup screen has the following buttons. • USB button Use USB link to connect to UV-22 and bring up the input settings screen. • LAN button Use LAN link to connect to UV-22 and bring up the input settings screen.
Page 21
Bring up the screen for setting the timeout interval for communication with the UV-22. • END button Terminate the application. Note If a communication error occurs, check the various settings and cable connections, and restart the com- puter and the UV-22.
Page 22
Version] to bring up the version screen. The screen shows the program version and other information. It also contains the button shown below. Version UV-22Viewer Version . For 32-bit Windows development Copyright (C) RION CO.,LTD. Version screen • OK button Closes the version screen.
Timeout setting screen The following item can be set from this screen. • Timeout Sets the timeout interval for communication with the UV-22. The setting range is 5 to 120 seconds in 1-second intervals. Note When using a LAN link, network traffi c and com- munication conditions can affect the transmission.
UV-22 via the USB link. If the communication can be established successfully, the LAN Setting screen appears. The LAN Setting screen serves to make LAN related settings for the UV-22 and for the computer. LAN Setting screen The LAN Setting screen gives access to the following items.
Page 25
This section comprises the following item. The setting is saved in the computer. ° IP address Specifi es the IP address of the UV-22 that the computer should look for when connected via LAN. (Use the same IP address as entered in the UV-22 LAN settings section.)
Starting the Application Instantaneous value display and setup screen When a connection to the UV-22 has been successfully established by clicking the USB or LAN button on the startup screen, the instantaneous value display and setup screen as shown below appears. The screen shows instantaneous values and also gives control over various setup items.
Page 27
Starting the Application • CANCEL button Click this button to cancel any changed settings. The instantaneous value display and setup screen also contains the fol- lowing menu. • Help menu Selecting the Help menu gives access to the following sub menu. °...
Page 28
The “No.” fi eld corresponds to the ID number assigned to the linked unit. The indication fi eld shows the instantaneous value of the unit (UN-14/UV-15) linked to the UV-22. The background color of the fi eld indicates the current status.
Page 29
Starting the Application The measurement unit fi eld shows which unit applies to the value shown in the indication fi eld. The following indications are possible. • No equipment connected: Unit fi eld is blank. • UN-14 connected: Unit fi eld shows “dB”. •...
Contents of input setting This section allows making input settings, measurement settings, and user fi lter settings for equipment connected to the UV-22. The section has three categories. Select the respective category by clicking the appropriate tag at the top.
UV-22. The INPUT field lets you specify input connector related settings of the UN-14/UV-15 unit linked to the UV-22. If there is no unit at a specifi c ID number, the INPUT fi eld only shows “---”. If there is a unit at a specifi c ID number, but the obtained input value is not...
Page 32
Starting the Application Depending on the selected INPUT setting, TEDS communication mode is enabled in the following cases. • Connected unit is UN-14 and REAR CCLD TEDS is selected • Connected unit is UV-15 and FRONT CCLD TEDS is selected When the INPUT setting is changed to TEDS communication mode, changing the Sensitivity value is not possible, and the fi eld becomes blank (because the Sensitivity value is not yet determined at that point).
MEASURE SETTING tag HPF setting ID number Time weighting/ LPF setting RANGE setting detection type setting Frequency weighting/ measurement mode setting Measurement setting category The “No.” fi eld corresponds to the ID number assigned to the unit linked to the UV-22.
Page 34
The RANGE fi eld lets you select or display the range setting of the UN-14 or UV-15 unit linked to the UV-22. If there is no unit at a specifi c ID number, the RANGE fi eld only shows “---” and cannot be changed.
Page 35
The HPF fi eld allows setting a high-pass fi lter value for the unit connected to the UV-22. If there is no unit at a specifi c ID number, the HPF fi eld only shows “---” and cannot be changed.
UV-22. The HPF fi eld allows specifying a high-pass fi lter value for the unit connect- ed to the UV-22. If there is no unit at a specifi c ID number, the HPF setting cannot be changed. The LPF fi eld allows specifying a low-pass fi lter value for the unit connected to the UV-22.
Starting the Application Important To enable the user fi lter settings made here, the respective HPF or LPF setting must be selected in the HPF or LPF fi eld under the MEASURE SETTING tag. Making a global setting By holding down the Shift key while changing the setting of an item, the setting can be made globally for all units of the same type.
Need help?
Do you have a question about the UV-22 and is the answer not in the manual?
Questions and answers