POWER GENERATOR RocwooD Instruction Manual NOTE: PLEASE READ INSTRUCTIONS CAREFULLY BEFORE USE.
Page 2
INTRODUCTION DANGER Indicates a possibility of death or serious injury if instructions are not followed. WARNING Indicates a strong possibility of severe personal injury, loss of life and equipment damage if instructions are not followed. [CAUTION] Indicates a possibility of personal injury or equipment damage if instructions are not followed. NOTE : Gives helpful information.
SAFETY INSTRUCTIONS Please make sure you review each precaution carefully. WARNING Do not operate the generator near fuel because of the potential danger of explosion or re. Do not ll the fuel tank with fuel while the engine is running. Do not smoke or use naked ame near the fuel tank. Be careful not to spill fuel during refueling.
Page 4
SAFETY INSTRUCTIONS WARNING If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water. WARNING Be extremely careful that all necessary electrical grounding procedures are followed during each and every use.
PRE OPERATION CHECKS CHECK ENGINE OIL Before checking or re lling oil, be sure generator is located on stable and level surface with engine stopped. • Remove oil ller cap and check the engine oil level. • If oil level is below the lower level line, re ll with suitable oil (see table) to upper level line.
Page 8
PRE OPERATION CHECKS CHECK ENGINE FUEL Use 4-stroke automotive detergent oil of API service class SE or higher grade (SG, SH or SJ is recommended). SAE 10W-30 or 10W-40 is recommended for general, all-temperature use. If single viscosity oil is used, select the appropriate viscosity for the average temperature in your area WARNING Do not refuel while smoking or near naked ame or other such potential re hazards.
Page 9
PRE OPERATION CHECKS CHECKING COMPONENT PARTS Check following items before starting engine: • Fuel leakage from fuel hose, etc. • Bolts and nuts for looseness. • Components for damage or breakage. • Generator not resting on or against any adjacent wiring CHECK GENERATOR SURROUNDINGS WARNING Make sure you review each warning in order to prevent re hazard.
Page 10
PRE OPERATION CHECKS WARNING Death, personal injury and/or property damage may occur unless instructions are followed carefully. • Use battery of recommended capacity. • Turn the starter switch to the “STOP” position when mounting or dismounting battery. When mounting battery, connect the positive (+) cable rst and then the negative (-) cable to the battery. Be careful not to short battery cables.
OPERATION INSTRUCTION [CAUTION] • Check the oil level before each operation as outlined by the article “CHECK ENGINE OIL “ STARTING THE GENERATOR (a) Turn the Engine switch to the position “ON”. (b) Turn the AC circuit breaker to the position “OFF”. (c) Open the fuel valve.
Page 12
OPERATION INSTRUCTIONS ( e) [Recoil starter model] Pull the starter handle slowly until passing the compression point (resistance will be felt), then return the handle to its original position and pull briskly. • If the engine fails to start after several attempts, repeat above procedures with choke lever returned to “OPEN”...
OPERATION INSTRUCTIONS USING ELECTRIC POWER WARNING • Make sure that the appliance is switched OFF before connecting it to the generator. • Do not move the generator while it is running. • Be sure to ground the generator if the connected appliance is grounded. Failure to ground unit may lead to electrical shock.
Page 14
OPERATION INSTRUCTIONS TABLE 1 WARNING • To take power out from the TWIST LOCK RECEPTACLE, insert the plug into the receptacle, and turn it clockwise to the lock position. • Be sure to ground the generator if the connected electrical device Is grounded. NOTE : When the AC circuit breaker turns o during operation, the generator is over loaded or the appliance is defective.
Page 15
OPERATION INSTRUCTIONS ( c) Turn the AC circuit breaker to the position “ON”. ( d) Turn on the switch of the appliance. VOLTAGE SWITCH(If applicable) Select the voltage using the VOLTAGE SWITCH in accordance with the electrical appliance. Refer to TABLE 2.
Page 16
OPERATION INSTRUCTIONS (2) DC APPLICATION DC receptacle (Only for charging 12 volt battery) For charging 12 voltage battery, 12V-8.3A (100W) of maximum AC power can be taken out from the DC receptacle by means of the exclusive DC cable. The exclusive DC cable is come with your generator set (included in the package).
Page 17
OPERATION INSTRUCTIONS Battery Charging Procedures : 1) Stop engine. 2) Remove all connections from battery. 3) Insert the plug of exclusive DC cable into DC receptacle. 4) Connect positive (red) clip of DC cable to positive (+) terminal on battery, and then connect negative (black) clip of DC cable to negative (-) terminal on battery.
Page 18
OPERATION INSTRUCTIONS STOPPING THE GENERATOR (a) Turn o the power switch of the electric equipment and unplug the cable from receptacle of the generator. (b) Turn the AC circuit breaker to the “OFF” position. (c) Allow the engine about 3 minutes to cool down at no-load before stopping.
WATTAGE INFORMATION CHOOSING THE CORRECT GENERATOR: Domestic Generators are for backup use only and are not recommended for continuous use. It is rec- ommended to allow 20% above the wattage you need when choosing a generator. So a 1000W heater would generally need a 1200W generator.
Page 20
HOME APPLICATIONS CONTRACTOR APPLICATIONS RECREATIONAL APPLICATIONS FARM EQUIPMENT...
Page 21
WATTAGE INFORMATION (CONTINUED) Depending on their wattage output, generators will run anything from a small lamp to a number of large appliances. To determine the size generator you will need, total the wattage of the maximum number of items you will be running simultaneously. For example: running a 1 00 watt light bulb, a 200 watt slow cooker, a 1 ,200 watt refrigerator with a start up wattage of 2,900 watts and a 750 watt TV would require 3,950 watts.
MAINTENANCE DAILY INSPECTION Before running the generator, check the following service items: • Enough gasoline • Clean air cleaner element • Enough clean engine oil • Loose or broken bolts and nuts PERIODIC MAINTENANCE Periodic maintenance is vital to safe and e cient operation of your generator Check the table below for periodic maintenance intervals.
Page 23
MAINTENANCE Periodic Maintenance Schedule table NOTE : Initial oil change should be performed after rst twenty (20) hours of operation. Thereafter change oil every hundred (100) hours. Before changing oil, check for a suitable way to dispose of old oil. NOTE : As to the procedures for these items, please refer to the SERVICE MANUAL or consult your nearest service dealer.
MAINTENANCE “HOW-TO” CLEANING AND ADJUSTING SPARK PLUG (a) If the plug is contaminated with carbon, remove it using a plug cleaner or wire brush. (b) Adjust the electrode gap to 0.6 to 0.7 mm (0.024 to 0.028 in.). CLEANING FUEL STRAINER Dirt and water in the fuel are removed by the fuel strainer.
Page 25
MAINTENANCE “HOW-TO” Brush Maintenance Essentials (Disassembly and Assembly) Disassembly 1. Remove the two ange bolts, then remove the bracket cover. 2. Remove the two ange bolts, then remove the brush. Assembly 1. While pressing the brush against the slip ring, secure it by tightening it with the two ange bolts.
PREPARATION FOR STORAGE The following procedures should be followed prior to storage of your generator for periods of 6 months or longer. • Drain fuel from fuel tank carefully by disconnecting the fuel line. • Gasoline left in the fuel tank will eventually deteriorate making engine starting di cult.
TROUBLESHOOTING When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity, contact your nearest further information or corrective procedures dealer or service shop for When Engine Fails to Start : When No Electricity Is Generated at Receptacle :...
EC DECLARATION OF CONFORMITY We SDG TRADING LTD of Rocwood House, Lightwood Green Industrial Estate, Overton-on-Dee, Wrexham, LL13 0HU (importer) declares that the product: Designation: Petrol Generator Model(s) : RWPG1, RWPG1E COMPLIES WITH THE PROVISIONS OF THE FOLLOWING EUROPEAN DIRECTIVES: 2006/42/EC 2014/30/EU ‐‐ COMPLIES WITH THE PROVISIONS OF THE FOLLOWING HARMONIZED STANDARDS: EN ISO 12100:2010, EN ISO 8528‐13:2016, EN 55012:2007+A1:2009 ‐‐ Notified Body: Ente Certificazione Macchine Srl Address: Via Ca’ Bella, 243 – Loc. Castello di Serravalle – 40053 Valsamoggia (BO) ‐ ITALY Authorised signatory and technical file holder Date: 10/01/2022 ...