KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
• Serious injury or death could occur
• Disconnect ALL power sources before removing back panel. Power should only be re-connected after
electrical installations are complete and back cover replaced
• Be certain the power source conforms to specifications outlined on heater label
• Assure to connect green wire from heater to ground connection from electrical supply, not to a live or
"hot" conductor
• Engineer/Electrician/Installer to determine suitability of this appliance in intended application and
compliance with all local, state/provincial and National electrical Code (NEC) requirements
• Do not use in locations containing hazardous or explosive atmospheres.
ELECTRICAL RATING
SMRTTIM40
SMRTTIM60
WARNING SERIOUS INJURY OR DEATH COULD OCCUR, DISCONNECT ALL
POWER PRIOR TO SERVICE
Due to ongoing product improvements, specifications and dimensions are subject to change without notice and without incurring obligations.
IOM ▪ SMRTTIM60/40
SMRTTIM60 and SMRTTIM40
Installation & User Manual
S
AFETY WARNING
ALL INSTALLATIONS/SERVICE MUST ONLY BE
PERFORMED BY A LICENSED/CERTIFIED ELECTRICIAN
TO LOCAL AND NATIONAL ELECTRICAL CODE (NEC).
WARNING: SHOCK AND FIRE HAZARD:
208 - 240VAC 50/60HZ, 16.6A MAX CURRENT, 4000W max load
208 - 240VAC 50/60HZ, 25A MAX CURRENT, 6000W max load
SPE-1000 CANADA INSPECTED
Rev 2. 11.19.22
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMRTTIM60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Solaira SMRTTIM60

  • Page 1 Solaira SMaRT Timer On/Off Control SMRTTIM60 and SMRTTIM40 Installation & User Manual KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE AFETY WARNING ALL INSTALLATIONS/SERVICE MUST ONLY BE PERFORMED BY A LICENSED/CERTIFIED ELECTRICIAN TO LOCAL AND NATIONAL ELECTRICAL CODE (NEC). WARNING: SHOCK AND FIRE HAZARD: •...
  • Page 2: Installation

    Important: Read carefully the following information before installing the unit. The SMRTTIM60 and SMRTTIM40 should be fixed securely using the four mounting holes accessible from the front of the unit. Remove the lid to access the mounting holes. To ease installation, a mounting template is provided opposite to locate the 4 mounting hole centres.
  • Page 3 Important! Ensure all ground wires are connected to maintain ground continuity to the heater fittings. Check all wiring and make sure the cable glands are tightened. Illustrative Wiring Diagram SMRTTIM60* *Connection diagram is for illustrative purpose only. Installation must be carried out by certified electrician to local, state/provincial and National Electric Code (NEC) requirements.
  • Page 4 SMRTTIM60 Mounting Template Wiring SMRTTIM40 The unit is fitted with two cable glands. Only one cable should be fitted per gland to prevent degrading the unit’s IP rating. When fitting two lamps, refer to ‘Wiring Diagram’ for an alternative wiring configuration using a junction box.
  • Page 5 Press the push-button on the front of the unit to switch the lamps on. Due to ongoing product improvements, specifications and dimensions are subject to change without notice and without incurring obligations. IOM ▪ SMRTTIM60/40 Rev 2. 11.19.22...
  • Page 6: Technical Specification

    Rising Clamp Operating Temperature -20 to 40°C Protection Rating IP65 Gland Diameter Max Cable Entry 2.5mm² Due to ongoing product improvements, specifications and dimensions are subject to change without notice and without incurring obligations. IOM ▪ SMRTTIM60/40 Rev 2. 11.19.22...
  • Page 7: Troubleshooting

    3. No charge for travel and/or mileage will be allowed to purchaser. 4. SOLAIRA reserves the right to make changes in design or make any improvements on any products. The right is always reserved to modify our equipment because of new technology, underwriter’s requirements and/or government regulations.
  • Page 8 125 Traders Blvd. # 4, Mississauga, Ontario, Canada, M4Z Tel: 905-568-7655, EXT 23 SERVICE, Fax:905-568-7521 info@solairaheaters.com Due to ongoing product improvements, specifications and dimensions are subject to change without notice and without incurring obligations. IOM ▪ SMRTTIM60/40 Rev 2. 11.19.22...