WALDIS First 850 Installation And Maintenance Instructions Manual

Safes resistance level iv/v as per en1143-1

Advertisement

Quick Links

www.tresore.ch
INSTALLATION AND MAINTENANCE INSTRUCTIONS
WALDIS SAFES
RESISTANCE LEVEL IV / V
AS PER EN1143-1

Advertisement

Table of Contents
loading

Summary of Contents for WALDIS First 850

  • Page 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS WALDIS SAFES RESISTANCE LEVEL IV / V AS PER EN1143-1...
  • Page 2 Thank you Thank you so much for putting your trust in Waldis for your security needs. You’ve chosen to buy an EN1143-1-certified safe. A high-quality Swiss product checked and approved by the VdS. Please read these instructions carefully before setting up your safe!
  • Page 3: Table Of Contents

    Contents 1. General information ........................1 1.1. Safety instructions ......................1 1.2. Table of weights ........................1 1.3. Regulations and insurance ....................2 1.4. operating elements ......................2 1.5. Set-up ........................... 2 2. Installation............................ 3 2.1. Positioning against the building wall ................3 2.2.
  • Page 4: General Information

    1. General information Every WALDIS First and WALDIS Premium safe is equipped with an electronic security lock. To operate the lock, please use the 500.0024 / 500.0026 instruction manuals OM_PAXOS_V005_20190222_EN enclosed. You can find the comprehensive instruction manual, produced by the manufacturer, at: www.domakaba.com.
  • Page 5: Regulations And Insurance

    1.3. Regulations and insurance For all safes with a net weight of less than 1000 kg, professional anchoring either during construction or by the client is a minimum requirement of the EN1143-1 standard. For this reason, all safes are equipped with 8 bore holes (4 on the back wall and 4 on the base) with a diameter of 14.5 mm.
  • Page 6: Installation

    2. Installation 2.1. Positioning against the building wall When positioning the safe, please observe the minimum distance (A) from the wall in order to be able to open the door more than 90º. If you want to be able to use the safe’s full internal diameter, you also need to observe the minimum distance (B) from the strip side to the wall so that the door can be opened to 130º.
  • Page 7: Disassembly, Interior Construction

    2.2. Disassembly, interior construction To correctly anchor the safe (Section 2.3), its complete chrome-steel interior construction (lid, side walls, base, and rear wall) have to be completely disassembled. It is important to remove the individual metal plates with care so as to avoid scratching them. Follow this procedure to disassemble the safe: CAUTION: CUTTING DANGER ON THE METAL SHEETS! Open the safe as per the 500.0024 /...
  • Page 8 Repeat Step 5 for the right-hand side wall. Lift the base slightly and then pull it out of the safe diagonally. Make sure to hold the rear wall in place with your hand! Allow the rear wall to tilt forwards from the top and then turn it diagonally forwards onto one side.
  • Page 9: Anchoring The Safe

    Anchoring the safe PLEASE NOTE: Assembly and anchoring may only be carried out by WALDIS Tresore AG’s trained staff or by authorised specialists! WALDIS Tresore AG accepts no liability for damage to people or property in case of incorrect assembly and anchoring.
  • Page 10 In order to drive the supplied drop-in anchor into the building wall or building floor at the assembly location in advance, please consult the following table of measurements for drilling patterns for all WALDIS First and Premium models. Front view (without doors)
  • Page 11: Procedure

    2.3.4. Procedure The safe is delivered with 4x cylinder screws with an M12x30 internal hex (DIN 912, strength grade 12.9), 4x M12 washers (DIN 125 A) and 4x M12x50 drop-in anchors. If it is not possible to use the installation material specified or it is not possible to anchor the safe, please consult your property insurance provider to find an alternative anchoring solution.
  • Page 12: Assembly, Interior Construction

    2.4. Assembly, interior construction After anchoring the safe, its chrome-steel interior construction (lid, side walls, base, and rear wall) has to be completely assembled again. It is important to assemble the individual metal plates with care so as to avoid scratching them. CAUTION: CUTTING DANGER ON THE METAL SHEETS! Allow the rear wall to tilt forwards from the top and then turn it...
  • Page 13 Guide the left-hand side wall into the safe diagonally and plug it into the plug connection in the base. As soon as the side wall is plugged into the base, it can be stood upright on the left-hand side and screwed in (4mm Allen key) at the centre of the safe using the cylinder screw.
  • Page 14: Cable Entry / Power Connection

    2.5. Cable entry / power connection As standard, each safe is equipped with three cable entry openings. These are located on the right-hand side, in the lower rear area of the safe. If none of the options listed below have been ordered, they are closed. 1.
  • Page 15: Maintenance And Care Instructions

    (Art. 100, Para. 1 OR). The customer also recognises WALDIS’ right to use external companies to fulfil the additional services listed. In this case, WALDIS’ liability is limited to selecting and instructing the external companies with care (Art.
  • Page 16: Guarantee Against Theft

    WALDIS or an authorised partner company. If the secure storage box is not positioned, anchored or moved by WALDIS or an authorised partner company, the theft guarantee terminates immediately.