Assembly and Commissioning
Instructions
P
NT-s-2 Ks2 / KsA - 230 V AC / 24 V DC
ower suPPly

Advertisement

loading
Need help?

Need help?

Do you have a question about the NT-S-2 KS2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aumuller NT-S-2 KS2

  • Page 1 Assembly and Commissioning Instructions NT-s-2 Ks2 / KsA - 230 V AC / 24 V DC ower suPPly...
  • Page 2: Table Of Contents

    Safety Instructions 3 - 8 Data sheet: 680029 - Power supply NT-S-2 KS2/KSA - 230 V AC / 24 V DC Data sheet: 680027 - Power supply NT-S-2 KS2/KSA - 230 V AC / 24 V DC Circuit Diagram: 680029...
  • Page 3 Failure to comply with the warning notes can lead to damage to property. Useful note for an optimum installation. Note regarding the system configuration using the free software of the Control Unit manufacturer (USB connection). Power supply NT-S-2 KS2 / KSA...
  • Page 4 Directive 2006/42/EG when the uti- purpose for ventilation in accordance with EN12101-2. lization or operation of the control device or the connected window drives deviate from their intended use! Power supply NT-S-2 KS2 / KSA...
  • Page 5 > 1,5 m, inaccessible for public (7.12.1) Declaration of Conformity power operated window aution Information in parentheses refers + CE label to the chapters of DIN EN 60335-2-103. Keep people away during closing! Power supply NT-S-2 KS2 / KSA...
  • Page 6: Safety Instructions

    The required mounting material must be modified to fit the stallation, specifically: occurring load. • VDE 0100 Setting up high-voltage systems up to 1000 V • VDE 0815 Wiring cables • Specimen Guideline on Conduits German designation (MLAR). Power supply NT-S-2 KS2 / KSA...
  • Page 7 It is imperative that the information pro- vided in the installation instructions of ArNiNg the controlled window drives is observed and obeyed! Power supply NT-S-2 KS2 / KSA...
  • Page 8 For placing on the market, installation and operation out- side Germany, the relevant national laws, regulations, standards and safety provisions apply. The contractor is responsible for proper installation or operation and the issue of a Declaration of Conformity according to European guidelines. Power supply NT-S-2 KS2 / KSA...
  • Page 9: Data Sheet: 680029

    Data sheet Data sheet: Power supply NT-S-2 KS2/KSA - 230 V AC / 24 V DC 2,0 A Power supply NT-S-2 KSx Part.-No.: 680029 Operating voltage: 230 V AC (195 – 253 V AC, 50/60 Hz) Rated power consumption: 30 W Output voltage: 24 V DC (20 –...
  • Page 10: Circuit Diagram: 680029

    Circuit Diagram Circuit Diagram: Power supply NT-S-2 KS2/KSA - 230 V AC / 24 V DC 2,0 A Power supply NT-S-2 KSx: 680029 680029 24V DC Connect the drive 24V DC WH without function (insulate cables safely) for custom- made products.
  • Page 11: Circuit Diagram: 680027

    Circuit Diagram Circuit Diagram: Power supply NT-S-2 KS2/KSA - 230 V AC / 24 V DC 2,0 A Power supply NT-S-2 KSx 680027 680027 continuous voltage for flat scan (pinch protection) 24V DC Connect the drive 24V DC WH without function (insulate cables safely) for custom- made products.
  • Page 12 Power supply NT-S-2 KS2 / KSA...
  • Page 13: Liability

    We reserve the right to change or discontinue products at any time without prior notice. Illustrations are subject to change. Although we take every care to ensure accuracy, we cannot accept liability for the content of this document. Power supply NT-S-2 KS2 / KSA...
  • Page 14 Power supply NT-S-2 KS2 / KSA...
  • Page 15: Certificate And Declaration