Set Black Mark Sensor As Media Sensor And Calibrate The Black Mark Sensor; Set Gap Sensor As Media Sensor And Calibrate The Gap Sensor - TVS LP 46 PLUS User Manual

Thermal transfer/direct thermal bar code printer
Table of Contents

Advertisement

Printer configuration will be restored to defaults as below after initialization.
Parameter
Speed
Density
Label Width
Label Height
Sensor Type
Gap Setting
Print Direction
Reference Point
Offset
Tear Mode
Peel off Mode
Cutter Mode
Code Page
Country Code
Clear Flash Memory

4.3.4 Set Black Mark Sensor as Media Sensor and Calibrate the Black Mark Sensor

Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green/amber after 5 green blinks. (Any green/amber will
do during the 5 blinks).
The LED color will be changed as following:
Amber  red (5 blinks)  amber (5 blinks)  green (5 blinks)  green/amber (5 blinks)
 red/amber (5 blinks)  solid green

4.3.5 Set Gap Sensor as Media Sensor and Calibrate the Gap Sensor

Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns red/amber after 5 green/amber blinks. (Any red/amber
will do during the 5 blinks).
The LED color will be changed as following:
Default setting
127 mm/sec (5 ips) (203DPI)
8
4" (101.5 mm)
4" (101.5 mm)
Gap sensor
0.12" (3.0 mm)
0
0,0 (upper left corner)
0
On
Off
Off
850
001
No
29

Advertisement

Table of Contents
loading

Related Products for TVS LP 46 PLUS

Table of Contents