PROBLEM SOLVING

The A 1000 / A 2000 is designed and manufactured for severe environments and tasks, but the user
must note that the machine components must be protected from knocks and blows. Filter and sealing
connections are carefully chosen to serve the operator. Therefore, the machine must be handled with
care if it is to work correctly for many years.
Problem
The fan does not start
The fan stops immediately
The fan runs,
but suction is poor
Dust blows from unit
Abnormal noise

TECHNICAL DATA

Air scrubber
Power
Voltage
Current
Power supply
Airflow

HEPA FILTER

Filter Area
Dimension LxWxH
Weight
E: sales@kevmor.com.au | P: (08) 9277 7177
Cause
No power
Cable defective
Switch defective
Wrong fuse
Blocked filter
Cover loose
Sealing defect
Defective or loose filter
Keep these instructions!
A 1000
0,285 kW
230
3,3 A
1-phase
3
500/1000 m
/h / 300-600 CFM
Filter classification: H13
2
2
3,5 m
/ 60 ft
mm: 465x385x466
in: 18,3x15,1x18,3
20 kg / 44 lbs
Kevmor Trade Supplies
11 Belmont Avenue, Belmont WA 6104
Procedure
Connect the machine
Change
Change
Connect the correct fuse
Change filter
Adjust
Change current seal
Adjust or change
Order service
A 2000
0,75 kW
230 V
1,2 A
1-phase
3
1000/2000 m
/h / 600/1200 CFM
Filter classification: H13
2
2
10,5 m
/ 150 ft
mm: 724x424x810
in: 28,5x16,7x31,9
38 kg / 84 lbs
W:
kevmor.com.au
6

Advertisement

loading

This manual is also suitable for:

A 1000A 2000