Yamaha YZ 2018 Series Owner's Service Manual page 344

Table of Contents

Advertisement

TIP
Before troubleshooting, disconnect the starter motor lead from the starter relay.
Fault code No.
Item
Fail-safe system
Diagnostic code No.
Diagnostic tool display
Procedure
Probable cause of malfunc-
Item
tion and check
1
Connection of Yamaha diag-
nostic tool coupler.
Check the locking condition
of the coupler.
Disconnect the coupler and
check the pins (bent or bro-
ken terminals and locking
condition of the pins).
2
Connection of wire harness
ECU coupler.
Check the locking condition
of the coupler.
Disconnect the coupler and
check the pins (bent or bro-
ken terminals and locking
condition of the pins).
3
Wire harness continuity.
4
Yamaha diagnostic tool mal-
function.
5
Malfunction in ECU.
Waiting for connection
No communication signal is received from the ECU.
Able to start engine (Unable when ECU is malfunctioning)
Able to drive vehicle (Unable when ECU is malfunctioning)
Maintenance job
Improperly connected 
Connect the coupler securely
or repair/replace the wire har-
ness.
Improperly connected 
Connect the coupler securely
or repair/replace the wire har-
ness.
Open or short circuit  Re-
place the wire harness.
light green–light green
Replace the Yamaha diag-
nostic tool.
Replace the ECU.
8-45
FUEL INJECTION SYSTEM
Confirmation of service
completion
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 2.
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 3.
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 4.
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 5.