Led indoor luminaires ceiling mount – with motion sensor 120-277vac / 60hz

Advertisement

LED Indoor Luminaires
Ceiling Mount – with Motion Sensor
120-277VAC / 60Hz
Standby Period
6
7
I
ON
ON
II
-
ON
III
ON
-
IV
-
-
V
ON
ON
VI
-
ON
VII
-
-
Daylight Sensor
1
2
I
ON
ON
II
-
ON
III
ON
-
IV
ON
ON
V
ON
ON
VI
ON
ON
VII
-
-
Detection Mode
6
I
ON
HS
II
-
LS
Standby dimming level
1
I
-
II
ON
III
-
Page 3 of 3
8
ON
0sec
ON
5sec
ON
5min
ON
10min
-
30min
-
60min
+ ∞
-
3
4
5
ON
ON
ON
5Lux
ON
ON
ON
15Lux
ON
ON
ON
30Lux
-
ON
ON
50Lux
ON
-
ON
100Lux
ON
ON
-
150Lux
-
-
-
Disable
2
ON
50%
-
20%
-
10%
Model #: BAYL2408LAJUDxx-MS
BAYL4608LAJUDxx-MS
Initialization
Switch function/three-stage dimming function: the light will be turned on
100% brightness by the initial energizing sensor, and will be turned off
after 10 seconds. During initialization, no external motion sensing
signal will be detected.
Two-phase dimming function: the light will turn on 100% brightness in
the initial energizing sensor, and turn to low brightness 10 seconds
later (the brightness set by stand-by dim level). During initialization, no
external motion sensing signal will be detected.
Factory setting
Detection Area: 100%, Hold Time: 5Sec, Daylight Sensor: Disable,
Stand-by Period: 0Sec, Dimming brightness preset function: 50%
Application notice
1.
The sensor should be installed by a professional electrician. Please
turn off the power before installing, wiring, changing the setting of the
DIP switch.
2.
The sensor which installed in the plastic and glass lampshade will
reduce the sensitivity. For every 0.120" increase in thickness, the
sensitivity will be reduced by 20%.
3.
The light sensitivity threshold is in a sunny environment, no shadow
and ambient light diffuse reflection. Ambient lux level could be different
in different environment, weather, climate, time-of day and season.
4.
The parameters of the sensor may need to be reconfigured in different
installation environments.
5.
This sensor is for indoor use only. It will affect the waterproof effect for
outdoor use. Wind, rain, and moving objects around will cause false
triggering.
6.
The distance between any inductive sensors should be greater than
9.8ft.
7.
Do not place the sensor close to high-density objects such as metal,
glass, concrete walls, etc, false triggering could happen. When the
sensor is installed in a metal lamp, metal reflective surface, or a narrow
enclosed environment, the microwave will be reflected repeatedly and
cause false triggering. Please reduce the sensitivity or contact the
manufacturer for technical support.
8.
Please ensure that there are no moving signals around the sensor,
such as fan,DC motor, sewer pipe, air outlet, etc., the sensor may
generate false trigger.
9.
The data on detection pattern is typical value tested without any lighting
fixture in factory, the detection range could be affected by moving
speed, installation height, motion object and different environment.
10.
Due to continuous improvement, the contents of this instruction could
be changed without prior notice.
8061660 R0