Download Print this page

ccei DHG-2 User Manual

Frost protection device

Advertisement

Quick Links

Table of Contents
1. Technical specifications ......................................................................................................... 2
2. Packaging content .................................................................................................................. 2
3. Description ............................................................................................................................. 2
4. Installation ............................................................................................................................. 2
5. Connection ............................................................................................................................. 3
6. Settings .................................................................................................................................. 3
A. Declaration of conformity ................................................................................................... 4
Read these instructions carefully before installing, commissioning and using
this product.
MPNT0184 v4.0EN (07/03/2017)
User manual
DHG-2
Frost protection device
Réf : PF10Y007

Advertisement

loading

Summary of Contents for ccei DHG-2

  • Page 1 User manual DHG-2 Frost protection device Réf : PF10Y007 Table of Contents 1. Technical specifications ......................2 2. Packaging content ........................2 3. Description ..........................2 4. Installation ..........................2 5. Connection ..........................3 6. Settings ..........................3 A. Declaration of conformity ....................4 Read these instructions carefully before installing, commissioning and using this product.
  • Page 2 1 user manual (this document) 3. Description DHG-2 is a device designed to protect the pool water against frost while forcing the filtration pump to run when there is a danger of freezing due to the outside temperature. Forcing the pump will move the water around and increase the pressure in the pipes which lowers the freezing point.
  • Page 3 6. Settings DHG-2 displays the temperature when it is powered on. The red light top left on the screen shows if the forced run is on. DHG-2 is factory preset to start the forced run when the temperature decreases bellow -2°C and to stop it when the temperature raises above 0°C.
  • Page 4 SET. To modify the set point press the cross up or down until the needed temperature is displayed. Wrong settings may prevent proper operation of DHG-2 and lead to pipes freez- ing. A. Declaration of conformity CCEI S.A.S (FR 47 40 35 21 693) declares that product DHG-2...