ISA Two User Guide
Insert
Pressing Insert places the Insert Return signal into the channel path before the Output connector, allowing the
inclusion of external effects units.
The Insert Send is always available and is post the input Gain and Filter & Phase controls.
Channel Meters
The LED meters indicate the level at the channel output connectors. The scale is in dBFS, ie., the level in dB,
relative to maximum output (reached when the '0' LED illuminates).
The default calibration is for '0' to indicate a signal level of 22 dBu
Meter Calibration
The level at which the '0' LED illuminates can be adjusted using the Peak Meter Calibration pot on the rear
panel. The default setting of 0 dBFS = 22 dBu occurs when the knob is in its central, detent position.
Rotating the pot sets the value between 0 dBFS = 16 dBu (fully anticlockwise) and 0 dBFS = 24 dBu (fully
clockwise).