  • Page 1 2 . E d i t i o n , D e c e m b e r 2 0 2 1 2 . E d i t i o n , D e c e m b e r 2 0 2 1 54677 Smoke Unit „Dual“ P/N 05020-24306...
  • Page 2: Table Of Contents

    Content 1. EU Declaration of Conformity 1. EU Declaration of Conformity ......... 2 ESU electronic solutions ulm GmbH & Co. KG, Edisonallee 29, 2. WEEE Declaration............. 2 D-89231 Neu-Ulm, herewith declares in its sole responsibility that the product complies in terms of 3.
  • Page 3: Important Hints - Please Read This First

    4. General properties We congratulate you to your purchase of an ESU smoke generator. The ESU smoke generator Dual for G and 1 Gauge models as well This manual aims to inform you step by step regarding the electri- as for larger 0 Gauge models generators realistic smoke and steam cal connection of this module.
  • Page 4: Installation Of The Smoke Generator

    There is only one tank for both exhaust smoke and cylinder • The smoke generator receives the exhaust chuff pulses via the steam. Only use ESU smoke distillate (part number 51990). Using green wire. The pulses may be supplied directly by a HALL sensor other liquids may cause damage to the paint finish, blocking the or (preferably) be generated directly by the decoder.
  • Page 5: Connecting With Ls 5 Xl & Ls 5 L Decoder

    Connection to decoder 6.3. Connecting with LokSound 5 XL & LokSound 5 L decoder This MUST be connected to the AUX1 output of the decoder. In this case the 4-pole plug is not needed. Cut it off and establish The AUX1 output is the only one that can supply the appropriate the connection as shown in Fig.
  • Page 6: Programming The Smoke Generator

    7.1. ESU LokSound 5 XL & LokSound 5 L decoder You can configure the smoke generator in many ways to meet your personal preference. This can only be done with the ESU Lok- Programmer 53451 because some adjustments in the sound flow are necessary.
  • Page 7: Sound Flow Settings

    “Function Mapping”. Select the func- The most important and comprehensive settings are found in the tion “ESU Smoke generator” in the row of the desired function “Sound” register. Adjust the desired heating temperatures and button. The ex-works setting for most LokSound 5 decoders is the revs in the sound flow.
  • Page 8 Programming You will find the most interesting parameters in the chapter „ESU Smoke generator”. • Fan: Here you may adjust the revs of the fan motor. The higher the value the faster turns the fan and the more smoke is ejected. The value “255”...
  • Page 9 Not applicable You may mark several conditions simultaneously by holding down The actual speed steps are called Dx in all ESU projects. Some the shift button while marking the induvial squares one after the sound projects contain D1 to D4, others go up to D8. These are other.
  • Page 10: Optimising Functions

    Programming If sound slot 2 is active in the list of available sound slots but is • Time until automatic switch off: Here you can set an automatic marked in grey, there is no reason to be concerned. This means switch-off time.
  • Page 11 Programming Now all you need to do is set appropriate values for heating tem- perature and fan speed in the “Cylinder blow-out” register. In our example this is entered in sound slot 9 “Cylinder blow-out”. The LokSound decoder “assumes” in case of sound slot greater than 4 that this must be cylinder steam and transmits the re- levant commands to the smoke generator.
  • Page 12: Firmware Update With The Lokprogrammer

    Support 7.3. Firmware update with the LokProgrammer 8. Support Of course, the firmware of ESU smoke generators can be updated Should you have questions regarding your smoke generator to with the LokProgrammer. However, the smoke generator must be which you have not found the right answer in this manual please removed from the model and directly connected to the LokPro- first contact your hobby shop.
  • Page 13 Notices...
  • Page 14 Alle anderen Warenzeichen sind Eigentum ihrer jeweiligen Rechteinhaber. ESU electronic solutions ulm GmbH & Co. KG entwickelt entsprechend seiner Politik die Produkte ständig weiter. ESU behält sich deshalb das Recht vor, ohne vorherige Ankündigung an jedem der in der Dokumentation beschriebenen Produkte Änderungen und Verbesserungen vorzunehmen.
  • Page 15: Guarantee Certificate

    Therefore ESU electronic solutions ulm GmbH & Co. KG grants you a warranty for the purchase of ESU products that far exceeds the national warranty as governed by legislation in your country and beyond the warranty from your authorised ESU dealer.
  • Page 16 Trouble shooting sheet 1. Personal data (Please write in block letters) Name: ....Street: ....ZIP/City: ....| | | | | | Country: ....Email: ....Phone: ....Date: ..... Signature: ..... 2. Error No Function (please describe the error in more detail) 3.

Table of Contents