Sylvania 6620LE Service Manual page 17

20” color lcd television
Hide thumbs Also See for 6620LE:
Table of Contents

Advertisement

4. Flicker Adjustment
Adjustment Point: VR201 (LCD Main CBA Unit)
LCD Main CBA Unit
Note: Use service remote control unit
1. Enter the Service mode. (See page 5-1)
2. Press "2" button on the remote control unit.
The following screen appears.
3. If Flicker Adjustment is not fit, the screen become the
following.
FLASH
(Go and Off)
4. Adjust VR201 so that flash stops.
VR201
The following
adjustment
attempted in the field. Only when replacing the
LCD Panel then adjust as a preparation.
5. White Balance Adjustment
Purpose: To mix red, green and blue beams correctly
for pure white.
Symptom of Misadjustment: White becomes bluish
or reddish.
Test Point
Adj. Point
CH o / p
Screen
buttons
M. EQ.
Pattern Generator,
Color analyzer
It carries out in a darkroom.
Perpendicularity
L = 50 cm
INPUT: WHITE 80%
Note: Use service remote control unit
1. Operate the unit for more than 20 minutes.
2. Input the White Purity (APL 80%).
3. Set the color analyzer to the CHROMA mode and
bring the optical receptor to the center on the LCD-
Panel surface after zero point calibration as shown
above.
Note: The optical receptor must be set perpendicu-
larly to the LCD Panel surface.
4. Enter the Service mode. Press "VOL p" button on the
service remote control unit and select "C/D" mode.
5-1. When "x" value and "y" value are not within specifica-
tion, adjust "DB(C/D1)" or "DR(C/D1)". Refer to "1.
Initial Setting."
Note: "DB(C/D1)" or "DR(C/D1)" must be adjusted
within ±10.
5-2. When "x" value and "y" value are not within specifica-
tion, adjust "DB(C/D2)" or "DR(C/D2)". Refer to "1.
Initial Setting."
Note: "DB(C/D2)" or "DR(C/D2)" must be adjusted
within ±10.
5-3
normally are not
Mode
Input
White
VIDEO1
Purity
VIDEO2
(APL 80%)
Spec.
x (0.256 to 0.316),
y (0.264 to 0.324)
Figure
Color Analyzer
Fig. 2
L0311EA

Advertisement

Table of Contents
loading

Table of Contents