iX02 Scale Reduction Filter Quick Installation Guide
The following guide has been produced to support installing the iX02 Scale Reduction Filter

Positioning

The filter should be positioned:
in an accessible location for future access
away from any strong smells
away from any heat sources
in an upright orientation where possible

Installation

Remove the iX02 filter from the box and position.
Remove the iX02 head from the box and attach to the top of the filter.
Connect the relevant fittings to both the inlet and outlet.
Flush a minimum of 10ltrs through the filter or until it runs clear.
Following the instructions shown on the water testing strips, test the water to
determine the water hardness (see chart on next page)
Remove the lid from the head and set the bypass based on the water hardness.
Place lid back onto head.

Important

Always test the water from the incoming supply (before filter)
If you are unable to test the water set to 3
If you are unsure of the reading set to 3
Never set the bypass to 0
The filter will simply become exhausted sooner and potentially cause taste issues
Supporting Images

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iX02 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Billi iX02

  • Page 1 Installation • Remove the iX02 filter from the box and position. • Remove the iX02 head from the box and attach to the top of the filter. • Connect the relevant fittings to both the inlet and outlet. • Flush a minimum of 10ltrs through the filter or until it runs clear.
  • Page 2 Test the water h ardness Remove lid on filter head S et the bypass as per the chart...

Table of Contents