CUBE • MC EN (translated from italian) INDEX FACSIMILE COPY OF EU DECLARATION OF CONFORMITY GENERAL WARNINGS SAFETY INSTRUCTIONS FIRST AID RULES GENERAL SAFETY RULES TRANSPORT, HANDLING AND UNPACKING DIMENSIONS AND WEIGHTS PACKAGE CONTENTS/PRE-INSPECTION MACHINE AND MANUFACTURER IDENTIFICATION PLATES POSITIONS DESCRIPTION OF MAIN COMPONENTS BODY PUMPING UNIT...
Installation, use and maintenance FACSIMILE COPY OF EU DECLARATION OF CONFORMITY The undersigned: PIUSI S.p.A. Via Pacinotti 16/A z.i. Rangavino - 46029 Suzzara - Mantova - Italy HEREBY STATES under its own responsibility that the equipment described below: Description: DIESEL FUEL DISPENSER Model: CUBE 70 MC Serial number: refer to Lot Number shown on CE plate affixed to product...
CUBE • MC EN (translated from italian) SAFETY INSTRUCTIONS Mains - pre- ATTENTION liminary checks You must avoid any contact between the electrical power supply and the fluid before instal- that needs to be FILTERED. lation Maintenance control Before any checks or maintenance work are carried out, disconnect the power source. FIRE AND To help prevent fire and explosion: EXPLOSION...
Installation, use and maintenance Do not operate the unit when fatigued or under the influence of drugs or alcohol. EQUIPMENT Do not leave the work area while equipment is energized or under pressure. MISUSE Turn off all equipment when equipment is not in use. Misuse can Do not alter or modify equipment.
CUBE • MC EN (translated from italian) GENERAL SAFETY RULES Essential protective Wear protective equipment that is: - suited to the operations that need to be performed; equipment character- - resistant to cleaning products. istics Personal protective Safety shoes; equipment that must be work Close-fitting clothing;...
Installation, use and maintenance DIMENSIONS AND WEIGHTS MODEL WEIGHT (Kg) PACKAGE DIMENSIONS (mm) CUBE MC 400 x 400 x 460 PEDESTAL KIT PACKAGE CONTENTS/PRE-INSPECTION Foreword Before assembly, make sure the machine is integer controlling all parts for possible damage that could hinder safety and functionality. In case of doubt, do not start up and contact the manufacturer's technical service.
CUBE • MC EN (translated from italian) MOUNTING EXAMPLE APPLY THREAD SEALER AT THE POINTS SHOWN IN THE PHOTO, BEFORE PROCEEDING WITH FINAL AS- SEMBLY MACHINE AND MANUFACTURER IDENTIFICATION The SELF SERVICE stations feature an identification plate that is attached to the shell showing - Model - Serial number / Year of manufacture...
Installation, use and maintenance PLATES POSITIONS The dispensing system is equipped with decals and/or plates to provide opera- tors with the necessary important information. Make sure that these do not deteriorate or become detached over time. NOTE Should this situation arise, please contact our support department and ar- range to have the damaged or missing plates sent back and replaced where necessary.
CUBE • MC EN (translated from italian) DESCRIPTION OF MAIN COMPONENTS BODY CUBE MC dispensers are designed for the transfer of diesel fuel for private use. Characterized by maxi- mum safety and simplicity of use, CUBE dispensers are dependable, high-performance equipment that is quickly installed and ready for use.
Installation, use and maintenance PULSER METER The K600/3 Pulser meter features a measurement system with high-precision oval gears designed for ac- curate fuel metering. These have a sturdy die-cast aluminium structure and are complete with inlet suction filter. They are easy to service and reliable. For further details, see the dedicated manual. CONTROL SYSTEM The electronic control system -MC- ensures the dispenser can only be used by authorised personnel.
CUBE • MC EN (translated from italian) TECHNICAL SPECIFICATIONS 10.1 TECHNICAL DATA MODEL Voltage Frequency Power Absorption Max Flow Rate CUBE MC70 MC 230 V 50 HZ 900 W 4,2 A 70 l/min CUBE MC70 MC 110 V 60 HZ 550 W 5,5 A 69 l/min...
Installation, use and maintenance INSTALLATION CUBE MC can be installed outside. Nevertheless, it is advisable to locate it un- der the shelterof a roof to ensure the dispenser’s longevity and provide greater comfort during refuelling inthe event of bad weather. The installation of the dis- penser must be carried out by skilledpersonnel and performed according to the instructions provided in this chapter.
CUBE • MC EN (translated from italian) 12.2 FIXING Before starting installation, make sure no packaging materials are trapped in the pipes. Prepare suitable stilts or fixing brackets depending on the fixing position of the CUBE MC. The tube coming from the tank must be aligned to the threaded inlet of the pump filter which is located under the CUBE MC.
Installation, use and maintenance 12.3 HYDRAULIC CONNECTIONS ATTENTION The use of accessories that are unsuitable and were not provided with the system is strictly prohibited. Piusi S.p.A. accepts no responsibility for damage to persons, property or the environment caused by failure to comply with this requirement.
CUBE • MC EN (translated from italian) 12.4 ELECTRIC CONNECTIONS ATTENTION The installation operations are performed with door open and power con- tacts accessible. All these operations must be performed with the appliance isolated from the power mains to avoid any risk of electric shocks! All the installation operations must be performed by qualified electro-tech- nical or electronic staff.
Page 18
Installation, use and maintenance ATTENTION For CUBE MC commissioning, no further power connections are required. All the elec- tronic components housed in the MC BOX are already wired up and factory tested. It is therefore NEVER necessary for the installer or station manager to open the MC BOX except to replace the protection fuses housed on the I/O card (see photo below).
CUBE • MC EN (translated from italian) STARTING FOREWORD To correctly commission the CUBE MC the sequence of operations indicated below must be followed and the MC control system functions must be known (see attached manual). ELECTRICAL Once the power connections have been made, the CUBE MC can be energised by POWER means of the master switch to be fitted by the installer on the upstream line.
Installation, use and maintenance 13.1 INITIAL PRIMING To prime the pump: - Take the nozzle off its seat - Enter the previously assigned PIN CODE (if the jumper is on) - Lift the control lever - The pump will start immediately and will continue running indefinitely until the control leveris moved to OFF position.
CUBE • MC EN (translated from italian) METER CALIBRATION Before using the CUBE MC station, check the METER ACCURACY. For this purpose, proceed as follows: • Enter a previously enabled USER PIN code. • Run the fuel into a calibrated container. •...
Installation, use and maintenance 15.1 FUEL DISPENSING ATTENTION Fuel shall be ABSOLUTELY dispensed under the User’s strict supervision. In case of simple configuration (no optional data to be entered), dispensing takes place as follows: Enter PIN CODE If the management system identifies an enabled pin code, the following mes- sages are displayed and the pump is enabled.
Page 23
CUBE • MC EN (translated from italian) OPENING AND -Lower the display cover CLOSING THE -Loosen the 2 screws on the right side (marked by the arrows) CUBE MC -Open the inspection side of the CUBE MC -To reclose it, perform these steps in reverse order. PUMP Check the pump, the pipes and other internal components of the station and keep them clean.
Page 24
Installation, use and maintenance ATTENTION Dirty or partially blocked filters can increase flow resistance and cause a con- siderable reduction in the maximum flow rate of the pump. Dirty or blocked pump suction filters also cause a big increase in vacuum during suction and this in turn can make the pump particularly noisy.
CUBE • MC EN (translated from italian) 16.2 SPECIAL MAINTENANCE In order to change the fuses inside the electronic board panel, we suggest proceeding as follows: - Interrupt power to the CUBE MC - Remove the cover of the MC BOX panel - Replace the burnt out fuses - Close the panel again - Restore power to the CUBE MC...
Installation, use and maintenance TROUBLESHOOTING PROBLEM POSSIBLE CAUSES POSSIBLE SOLUTIONS MOTOR NOT TURNING No electric power Turn the pump ON/OFF switch to the ON position. Recock the external re- sidual current circuit breaker. Check the electrical connections. Fuses burned out Replace the fuses in the electric panel Problems with the motor If the rotor is jammed, dismount and...
CUBE • MC EN (translated from italian) DEMOLITION AND DISPOSAL Foreword If the system needs to be disposed, the parts which make it up must be delivered to companies that specialize in the recycling and disposal of industrial waste and, in particular: Disposing of The packaging consists of biodegradable cardboard which can be delivered to packing materi-...