Download Print this page

Sealey AK4563D.V2 Manual

Air operated gear oil dispensing system

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETY
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this
equipment.
Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.
9
Maintain the pump station in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Non authorised parts will invalidate the warranty.
9
Use only to pump lubricants up to SAE 150 viscosity.
9
Ensure safety eye protection, oil resistant gloves and protective clothing are worn when using this product.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
After use, drain any fluids from the equipment before storage.
9
Dispose of waste liquids in accordance with local authority regulations.
9
Disconnect air pressure from equipment when not in use.
9
DO NOT exceed the maximum air pressure of 115psi.
8
DO NOT point the nozzle at people or animals.
8
DO NOT use the equipment near open flames.
8
DO NOT smoke whilst using this equipment.
8
DO NOT use to extract corrosive fluids.
8
DO NOT dismantle, tamper with or adapt the pump for any purpose other than for which it is designed.
8
DO NOT use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.
8
DO NOT leave the trolley on a slope, or traverse slopes, which may cause the unit to topple.
8
The unit must be stored on a level surface.
9
Keep the pump clean and store in a safe dry, childproof location.
9
WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting
the environment. All liquids must be disposed of according to local authority
regulations.
2. INTRODUCTION
Mobile oil dispensing unit with air operated 3:1 double acting pump for gear oil with
2"BSP fittings. Pump is supplied with air management system and connected to a
730mm rigid suction probe with non-return valve. Features 4m hose and digital oil
meter (Model No. AK4565D supplied). Also suitable for use with engine, hydraulic,
synthetic, gear and transmission oils up to SAE150 in containers up to 50kg.
3. SPECIFICATION
Model No: ...............................................................AK4563D
Maximum Air Pressure: ................................................115psi
Maximum Flow Rate: ................................................ 12L/min
Maximum Output Pressure: ........................................ 350psi
Maximum Trolley Capacity: ............................................ 50kg
Maximum Viscosity: .................................................. SAE150
Outlet Size: ...............................................................1/2"BSP
Pump Ratio: ...................................................................... 3:1
Recommended Air Pressure: ........................................ 70psi
Digital Hose End Meter
Model ......................................................................AK4565D
Accuracy: ..................................................................+/- 0.5%
Inlet: ..........................................................................1/2"BSP
Battery: ......................................... Lithium CR2 3V 1400mAH
© Jack Sealey Limited
AIR OPERATED GEAR OIL DISPENSING
SYSTEM
MODEL NO:
Wear protective
Wear safety
gloves
footwear
Original Language Version
AK4563D.V2
Wear protective
clothing
fig.1
AK4563D.V2 Issue 1 25/05/21

Advertisement

loading

Summary of Contents for Sealey AK4563D.V2

  • Page 1 AK4563D.V2 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 NOTE: Check the system for leaks, should an air leak be discovered, release the pressure, disconnect the air line and repair/replace the joint or seal before continuing. Original Language Version AK4563D.V2 Issue 1 25/05/21 © Jack Sealey Limited...
  • Page 3 MOVE key until each digit reads as per the measured value. Press MOVE key to visit each digit in turn. 5.9.5. Once value is correct (i.e. matches measured value) press and hold MOVE key until Cal mode quits (fig.10). fig.12 fig.13 Original Language Version AK4563D.V2 Issue 1 25/05/21 © Jack Sealey Limited...
  • Page 4 BATTERY REMOVAL SEE SECTION 6.1 Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.