TPS
Power supply (SMPS)
INSTRUCTION MANUAL
Thank you for purchasing Hanyoung Nux products. Please read the instruction
manual carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can view it any time.
▍Safety information
Please read the safety information carefully before the use, and use the product correctly.
The alerts declared in the manual are classified into
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or properties damage
Danger
• Do not touch or contact the input terminals because they cause electric shock.
Warning
• The contents of this manual may be changed without prior
notification.
• Please install an appropriate protective circuit on the
outside if malfunction or an incorrect operation may be
a cause of leading to a serious accident.
• This product doesn't have power switch so it should be
installed separately outside.
• Prior to using this product, accordingly the capacity of
required purpose should be considered.
• To prevent electric shock or malfunction of product,
do not supply the power until the wiring is completed.
• Please do not dissemble, manufacture, reform and reparir
this equipment. It leads to abnormality of movement,
electric shock, and fire.
• Do not use this product which required flammable and
explosive gas in an area.
• To prevent electric shock or malfunction of product, do not
5.0
85.0
7.5
supply the power until the wiring is completed.
• Please turn off the power when mounting / dismounting of
the product. This is a cause of electric shock, malfunction, or failure.
2-M3 Fixing hole
• To prevent defection or malfunction of this product,
supply proper power voltage in accordance with the rating.
• Please use this product after installing in the panel to
prevent electrical shock.
29.0
50.0
18.6
97.5
▍ Suffix code
Model
Code
TPS-
□ □
□
TPS Power supply (Enclosed Type)
20.5
60.5
16.6
Power output
15
15W, 30W, 50W, 75W, 100W, 150W, 220W, 350W, 450W
97.6
Number of
S
1 output
output voltage
5
5 VDC (220W, 350W, 450W are excluded)
12
12 VDC
Output voltage
15
15 VDC (350W, 450W are excluded)
classification
24
24 VDC
48
48 VDC (15W, 30W, 50W, 75W, 100W, 150W, 220W are excluded)
▍ Function
3-M3 Fixing hole
█ Rated input voltage
The product's input voltage is set at 220 VAC 50 - 60 Hz when shipping it out from our company.
Free power supply product works in 100 - 240 VAC 50 - 60 Hz even though it does not select input voltage.
Input
Free voltage 100 - 240 VAC 50 - 60Hz
voltage
14.0
109.0
TPS
135.0
TPS-15S, TPS-30S, TPS-50S,TPS-75S, TPS-450S
series
■ Instant maximum output power
The product's instant maximum output voltage can work up to rating's 130 % (220 VAC input Standard)
2-M3 Fixing hole
■ Adjustable Output voltage
20.0
90.0
25.0
Output voltage can be adjustable by adjustable resistance inside of the product. (more than ±5 % of rated output voltage)
■ Limited Inrush Current
This product has inrush current limit circuit but it should be considered carefully when selection of the external switch or fuse.
■ Short-Circuit Protection
When the output terminals shorted, the output is blocked. After eliminating the reason of short, voltage is output automatically.
■ Over-Voltage Protection
When the output voltage is reached at 115 to 140 % of the rated voltage. Blocking the current flow to protect the outside of
5.0
85.0
7.5
the connected equipment and system.
■ Over-Current Protection
2-M3 Fixing hole
When the output current exceeds the rated capacity, activate this protection to stop output.
After eliminating the reason of over-current, the output voltage is restored automatically.
■ Over-Temperature Protection
29.0
50.0
18.6
When PWM controller junction temperature reaches to 135 ~ 140 ℃, this protection
97.5
automatically stops switching to prevent components damage due to overheating.
■ Ripple Noise
Wiring should be shortened to reduce induction noise. Please use after reducing ripples noise sufficiently.
20.5
60.5
16.6
2-M3
▍ Derating curve
Fixing hole
97.6
100
80
LOAD
60
(%)
40
20
0
3-M3 Fixing hole
90 100 110 120 180 220 240 264
Ta=25 ℃
Input voltage (VAC) 60 Hz
100
14.0
109.0
12.0
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil, Michuhol-gu,
Incheon, Korea TEL : +82-32-876-4697
http://www.hynux.com
PT. HANYOUNG ELECTRONIC INDONESIA
Jl. Jangari RT.003/002 Hegarmanah Sukaluyu
Cianjur Jawa Barat Indonesia 43284
TEL : +62-21-5060-7210
Danger
Warning
and
according to their importance.
Caution
• Please use this product within 100 % of the rated output to
prevent damage or trouble.
• This product should be used on only the indicated rated input
voltage.
• The capacity of the voltage and current is depending on the
type of the wiring cable so this product should be connected
in an appropriate connectable wire.
• The ground terminal must be installed on to prevent
electric shock or electromagnetic wave.
• Foreign materials can be damage or malfunction in case of
entering into the product.
• Blowing fuse in inside of the product can cause chain damage or
malfunction to the other parts. Thus, repair should be required
promptly.
• This product has a certain level of leakage current. So it should
4.0
be used with extreme caution when using multiple units in
parallel because the sum of the leakage current is larger value.
• Please be cautious in high voltage in inside of the product to
prevent electrical shock.
2-M3 Fixing hole
• Please do not use it at the following locations for the safety
and reliability of the product.
· Easy to reach to water and fire place
· High ambient temperature and non-ventilated place
· Lots of debris materials and dust place
· Volatile and flammable substances place
24.0
· High humid place
· lots of vibration and shock place
Information
20.0
2-M3
Fixing hole
5.0
85.0
2-M3 Fixing hole
29.0
50.0
97.5
Manual-select input
100 - 120 / 200 - 240 VAC 50 - 60Hz
12.0
10.0
TPS-100S, TPS-150S, TPS-220S, TPS-350S
20.5
60.5
97.6
10.0
16.0
3-M3 Fixing hole
4.0
86.6
7.4
2-M3 Fixing hole
14.0
109.0
100
135.0
80
24.0
65.0
9.0
98.0
LOAD
60
(%)
40
2-M3 Fixing hole
20
20.0
90.0
0
90 100 110 120 180 220 240 264
20.0
68.0
10.0
98.0
Input voltage (VAC) 60 Hz
100
80
LOAD
5 V
60
(%)
40
20
0
-20 -10
0
10 20 30 40 50 60
Ambient temperature (℃)
12 - 24 V
▍ Block diagram
EMI NOISE
INPUT
FILTER
F.G
MH0201KE190624
5.0
85.0
7.5
▍ Product's wiring
2-M3 Fixing hole
█ Input terminal
• L(Live)/N(Neutral) : AC input Terminal.
• F.G(Frame Ground) : As an earth terminal, it is used to protect electric shock accident and
29.0
50.0
18.6
improve the electromagnetic interference.
97.5
█ Output terminal
• (+) / (-) : It is a DC output terminal.
Please pay a careful polarity on connecting
※ When output of GND is mutually short circuited, output of terminals would be short circuited each other.
※ Please make sure to ask us when you have any question before using the product.
20.5
60.5
16.6
※ Please make sure to check about the terminal's existence and connection method
97.6
because they are different depending on the types of model.
▍ Dimension
█ TPS-15S
5.0
86.6
7.4
2-M3 Fixing hole
3-M3 Fixing hole
29.0
14.0
109.0
12.0
65.0
9.0
135.0
98.0
20.5
2-M3 Fixing hole
20.0
90.0
25.0
68.0
10.0
2-M3
98.0
Fixing hole
█ TPS-30S
4.0
7.5
2-M4 X L8 Fixing hole
14.0
109.0
24.0
18.6
135.0
125.0
20.0
189.0
2-M3 Fixing hole
16.6
20.0
20.0
90.0
2-M3
Fixing hole
3-M4 X L8 Fixing hole
5.75
100.5
72.5
█ TPS-50S / TPS-75S
4.0
10.0
12.0
10.0
4.0
10.0
25.0
10.0
20.0
2-M3
Ta=25 ℃
Fixing hole
12 - 24 V
2-M4 X L8 Fixing hole
125.0
20.0
TRANSFORMER
INRUSH
RECTIFIER
CURRENT
& FILTER
LIMITING
SNUBBER
CIRCUIT
O. C. P
PWM
CONTROLLER
O. T. P
PHOTO
COUPLER
4.0
86.6
2-M3 Fixing hole
24.0
65.0
98.0
20.0
68.0
2-M3
Fixing hole
98.0
█ TPS-100S
85.0
7.5
4.0
10.0
103.6
7.5
3-M3 Fixing hole
50.0
18.6
97.5
4.0
10.0
97.7
13.3
10.0
60.5
16.6
2-M3
Fixing hole
97.6
2-M3 Fixing hole
20.0
90.0
15.0
125.0
10.0
16.0
█ TPS-150S / 220S
86.6
7.4
3-M3 Fixing hole
2-M3 Fixing hole
12.0
65.0
9.0
98.0
10.0
68.0
25.0
10.0
2-M3
TPS-350S/450S_외형도
98.0
Fixing hole
█ TPS-350S / 450S
103.6
7.5
2-M4 X L8 Fixing hole
3-M3 Fixing hole
125.0
20.0
189.0
97.7
13.3
15.0
3-M4 X L8 Fixing hole
2-M3 Fixing hole
5.75
16.0
100.5
72.5
90.0
15.0
125.0
4-M4 X L8 Fixing hole
10.0
+V
RECTIFIER
& FILTER
-V
4.0
VOLTAGE
7.4
DETECTION
O. V. P
4.0
9.0
10.0
2-M3
Fixing hole
4.0
86.6
7.4
2-M3 Fixing hole
2-M4 X L8 Fixing hole
24.0
65.0
9.0
98.0
125.0
20.0
189.0
10.0
20.0
68.0
2-M3
98.0
3-M4 X L8 Fixing hole
Fixing hole
5.75
100.5
72.5
4.0
10.0
103.6
7.5
3-M3 Fixing hole
2-M4 X L8 Fixing hole
4-M4 X L8 Fixing hole
125.0
4.0
10.0
97.7
13.3
10.0
189.0
125.0
40.0
199.0
3-M4 X L8 Fixing hole
2-M3 Fixing hole
20.0
90.0
15.0
3-M4 X L8 Fixing hole
125.0
10.0
16.0
100.5
5.75
100.5
79.5
10.0
215.0
4-M4 X L8 Fixing hole
133.0
41.0
4-M4 X L8 Fixing hole
133.0
41.0
125.0
40.0
199.0
10.0
10.0
20.0
20.0
5.75
72.5
4-M4 X
3-M4 X L8 Fixin
10
Need help?
Do you have a question about the TPS Series and is the answer not in the manual?
Questions and answers