Akw 28403 Installation & User Manual

Rise and fall cistern unit

Advertisement

Quick Links

Rise and Fall
Cistern Unit
INSTALLATION & USER GUIDE
Stock Code
28403
Read all instructions before installation and leave this document with the end user for future
reference as it contains important warranty information and how to register the product warranty.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 28403 and is the answer not in the manual?

Questions and answers

FRANKIE CUMMINS
January 22, 2025

how can I adjust the flow amount?

1 comments:
Mr. Anderson
February 10, 2025

You can adjust the flush flow amount by using the flush buttons on the unit. Press the full flush button for a 6L flush or the half flush button for a 3L flush. There are no other flow adjustments mentioned.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Akw 28403

  • Page 1 Rise and Fall Cistern Unit INSTALLATION & USER GUIDE Stock Code 28403 Read all instructions before installation and leave this document with the end user for future reference as it contains important warranty information and how to register the product warranty.
  • Page 2: Table Of Contents

    1: standard toilet Installation ........................19-20 option 2: AKW Bidet Installation ......................20-24 Installation - Covers, Panels, Hoses ..................25 option 2: AKW Bidet and Wall Hung Pan Installation ............................26 troubleshooting Guide ................................27 User Care ................................28...
  • Page 3: User Functions

    200 mm of vertical travel. NOTICE: The toilet and the toilet seat are not part of the appliance, they should be purchased separately. Also suitable with the AKW Bidet seat. Order: 01905 823 299 orders.akw-ltd.co.uk...
  • Page 4: Contents

    Contents Rise and Fall Cistern unit Glass panel Flush button Interior cover panel Flexible drain pipe Exterior cover panel General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 5 Washer air hose Blue half flushing Fixing nut air hose Rubber Countersunk head protective screw cover Flush pipe Extention Screw Flush pipe G1/2 Flexible 1.2 m gasket Hose Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 6: Technical Specification

    Max. load weight 200 kg Max. load weight each arm rest 120 Kg Waterproof rating IPX4 Ambient temperature 4~40C Drainage direction Wall and floor drainage Dimension H:1099xW:543xD:212mm Net weight 55.9 kg Colour of glass panel White General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 7: Dimensions

    Dimensions Max height 1299 200 MAX Min height 1099 1345 1099 708 - *Dimensions in mm Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 8: Important Safety Information

    • Children must not play with the appliance. Cleaning and user maintenance must not be undertaken by children. • For safety, people heavier than 200 kg must not use this appliance. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 9 Carefully remove the glass panel and put to one side until final installation steps. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 10: Site Positioning

    General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 11: Installation - Preparation

    Press the button on the armrest to raise the frame to the maximum height. Disconnect the power cable and isolate the mains connection. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 12 General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 13: Installation - Fixing

    Rotate the feet for finer adjustment. mark the four mounting positions on the wall by marking through the bolt hole positions. Bolt hole Bolt hole Bolt hole Bolt hole Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 14 Double check for hidden cables and pipework in the wall before drilling. Drill the fixing points with a 10 mm drill bit and insert the wall plugs. ensure that the fixings are solid into the supporting wall. Ø10 Drill General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 15 Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 16: Installation - Waste Outlet

    Use the adjustable support bracket for through wall waste outlets installations. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 17: Option 1: Standard Toilet Installation

    500 mm 180 mm 180 mm open the isolating valves to fill 180 mm the cistern and check for leaks. 180 mm 130 mm 110 mm Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 18 Use cable ties as required. Continue to install the exterior and Interior cover panels, page 21 step 11. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 19: Option 2: Akw Bidet Installation

    2: AKW Bidet Plumbing Installation Plumbing 1. attach the Tee Junction supplied with the aKW bidet unit directly onto the isolation valve at the top of the cistern unit. Attach the cistern hose to the other end of the isolating valve.
  • Page 20: Installation - Covers, Panels, Hoses

    1. connect a suitable length of cable to the centre Tee Junction port to reach the 3 pin connector supplied with the AKW Bidet unit. Feed the cable around the back of the frame and out through the front. ensure the cable will not be trapped when in operation.
  • Page 21 Position the outer cover up over the inner cover Attach the outer cover panel to top frame and align the slot holes with the screw holes. with the m4 screws and nuts. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 22 Locate and use all 4 glass panel hooks on each corner. Attach the push button assembly Push Button bracket Push Button Use the clamps to lock the push button bracket into position. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 23 Attach the air hoses blue air hose for half flush clear air hose for full flush half flush symbol full flush symbol Attach the top cover Locating pin and clip Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 24 25mm extra for the pan fixings. cistern frame. Install the rubber protective cover. Install the waste pipe into the waste outlet hole and the cistern flush pipe on the pan. see separate wall hung toilet instructions for more detail. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 25: Option 2: Akw Bidet And Wall Hung Pan Installation

    AKW Bidet Instructions (18-009-018) for connections and installation on how to feed the Bidet connections through the back of the pan up into the bottom entry AKW Bidet. When the installation is complete test the rise and fall operation, and test the flush mechanism for leaks and volume checks.
  • Page 26: Troubleshooting Guide

    Clean or remove items causing them to of the cabinet catches the other catch together inner panel. Glass panel touches item under the Always ensure that there are no items unit present under the unit before operating General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 27: User Care

    These instructions are provided to advise the minimum standards of installation and recommends what the best practice for the installation is. Due to the very wide variability of possible installation conditions, AKW cannot provide all circumstances for the installation. AKW cannot accept any liability in connection with this information or its use.
  • Page 28: Contact Us

    If the issue is still unresolved, contact AKW technical enquiries who will provide further advice and arrange for a maintenance engineer to visit if necessary. none of the foregoing affects your statutory rights.