Download Print this page

Novah Solray Select III Installation page 2

Led batten luminaire

Advertisement

Selecting the power output:
Note: The luminaire is always pre-set to the highest output. To change the brightness first, isolate the power. Locate the DIP switches on the power
supply and adjust using an insulated tool as follows:
Driver Switch
Output settings:
Selecting the Colour Temperature: By default, the colour temperature is 4000K to change adjust the switch on the LED driver.
Plug in Self-Test Emergency versions (Code ELSBPGF"):
Self-test emergency modules are purchased separately under the code ELSBGF and are fitted by the installer easily inside the product by simply unlicking
the connectors as per the instructions on the emergency kit.
The emergency products are fitted with 2.5W maintained self-test emergency kit giving a lumen output of 300LM for over 3 hours. The battery fitted
is a 1.5Ah LiFePO4 Lithium.
Self-Test Functions: Function Test: Carried out for 10 seconds every 30 calendar days
Duration Test: Will automatically make a full duration test every 180 calendar days to check the capacity of the batteries.
Note: If the mains supply fails during self-test period the module will terminate
LED Indicator:
# Full colour version of this installation manual is available at www.novah.co.uk
Microwave (Suffix "M"): See MH10 remote manual for details.
Installation:
1.
Isolate supply voltage before working with electrics.
2.
Carefully remove all packaging. Inspect the interior and exterior of the fitting to ensure no defects if there are please notify your retailer.*
3.
To open the fitting, insert a large flathead screwdriver between the rear and front of the fitting as shown in Fig.3 turn 90° and pull the two
parts to separate.
FIG 3:
4.
Disconnect the safety cords and set aside the front luminaire until later.
5.
Find a suitable location and using the supplied fitting (or appropriate fixings) attach to the wall or ceiling. (Note the luminaire must not be
installed close to a heat source).
6.
Feed the incoming power cables into the backplate either by the M20 cable entry at the side or rear and connect to the terminal block as
follows:
N = Neutral
= Earth
1 = Switched
2 = Permanent live (for emergency)
7.
Once connected securely attach the front Luminaire securing the safety cables first then connecting the orange power plug together.
8.
Connect the front luminaire to the back housing securely. Push the two parts carefully together until they click.
IMPORTANT NOTE: Ensure that the triangle safety look, orange connector and/or any cable(s) do not force down the piano key terminal block
when closing.
9.
Turn on your power. Note that LED generally have a higher inrush current and may trip your MCB or RCD breaker. In which case a change of
breaker type may be required (EG: B type to C type, C type to D type).
* Note for Microwave versions, they are installed but secured loose at the end for transportation purposes. You must use the provided nut to
secure the sensor on the thread ensuring the clear part of the sensor is pointed down.
Exclusions to Warranty:
Please visit our website terms and conditions for exclusions to warranty.
Disposal of Electronic Equipment WEEE Directive 2002/96/EC
This product falls within the scope of the Waste Electrical & Electronic Equipment Directive (WEEE), which means the product should not be disposed of as normal household
waste. Ensure that this luminaire and lamp is disposed of in accordance with the WEEE Directive. Contact a local Council Waste Depot. Local Amenity Site, or the Environment
Agency for further information. RoHS – All components and materials used in this product are RoHS 2002/95/EC compliant. Novah WEEE number: WEE/GA479TY