Technical Specifications - Lincoln Electric OERLIKON CITOSTEEL 250C Operator's Manual

Table of Contents

Advertisement

Technical Specifications

CITOSTEEL 250C
CITOSTEEL 250C PRO
CITOSTEEL 320C
CITOSTEEL 320C PRO
CITOSTEEL 380C PRO
CITOSTEEL 450C PRO
Input Voltage U
250C
250C PRO
320C
400V ± 15%, 3-phase
320C PRO
380C PRO
450C PRO
Input Power at Rated Cycle
250C
10,3 kVA @ 60% Duty Cycle (40°C)
250C PRO
320C
13,6 kVA @ 40% Duty Cycle (40°C)
320C PRO
380C PRO
17,1 kVA @ 40% Duty Cycle (40°C)
450C PRO
20,7 kVA @ 80% Duty Cycle (40°C)
Process
GMAW
250C
250C PRO
FCAW
SMAW
GMAW
320C
FCAW
320C PRO
SMAW
English
NAME
1
RATED OUTPUT
Open Circuit
Voltage
49Vdc
49Vdc
INPUT
EMC Class
A
Input Amperes I1max
14,7A
19,6A
26 A
30 A
Duty Cycle 40°C
(based on a 10 min.
Output Current
period)
60%
100%
60%
100%
60%
100%
40%
60%
100%
40%
60%
100%
40%
60%
100%
1
INDEX
W100000096
W100000097
W100000098
W100000099
W100000100
W100000101
Frequency
50/60Hz
PF
0,85
0,90
0,92
0,92
Output Voltage
250A
26,5Vdc
195A
23,8Vdc
250A
26,5Vdc
195A
23,8Vdc
250A
30Vdc
195A
27,8Vdc
320A
30Vdc
250A
26,5Vdc
195A
23,8Vdc
320A
30Vdc
250A
26,5Vdc
195A
23,8Vdc
320A
32,8Vdc
250A
30Vdc
195A
27,8Vdc
English

Advertisement

Table of Contents
loading

Table of Contents