SILICONE UNI-STOPPERS CODE 663-393 TO 663-395 CODE 664-089C INSTRUCTION MANUAL Before Use 1.Nomenclature 2.Operation 2-1 Set the Specimen Slide 2-2 Set Illumination 2-3 Adjust Focus 2-4 Adjust Diaphragm 2-5 Choose the Objective 2-6 Change the Lamp 3.General Specification 4.Parameter/Technical Terms 5.Troubleshooting *Please read these instructions carefully before use.
WESTLAB BEFORE USE EXTREME MONOCULAR 1. OPERATION MICROSCOPE, (1.) As the microscope is a precision instrument, always handle RECHARGEABLE, it with care, avoiding impact or abrupt movement during transportation. (2.) Do not let the microscope BE in the sunlight directly. Keep it in a dry and clean place.
WESTLAB 2. OPERATION EXTREME MONOCULAR The microscope is housed in a moulded styrofoam container. MICROSCOPE, First take the container out of the carton, and lay the container on its side. Open the container carefully and don’t let the optical RECHARGEABLE, items drop down, avoiding them being damaged.
Page 5
WESTLAB BIOLOGICAL MICROSCOPE GENERAL EXTREME SPECIFICATIONS (FOR OPTIONS) MONOCULAR MICROSCOPE, Model Install RECHARGEABLE, Parts Specifications M-100F M-100FL WF10X/18mm • • WF10X/18mm with pointer Methylene Chloride WF10X/18mm with reticle USER MANUAL WF15X/13mm WF20X/10mm CODE 664-089C H5X/ H6X H10X Huygens Eyepiece H12.5X H15X/ H16X 4X/0.10...
Page 6
WESTLAB 4. PARAMETER/TECHNICAL TERMS EXTREME 4-1 OBJECTIVE MONOCULAR MICROSCOPE, Numerical Parfocal Magnification Type Magnification Medium aperture distance market RECHARGEABLE, (N.A) (mm) (color ring) 0.10 0.25 Yellow achromatic USER MANUAL objective 0.65 Light blue 195mm 0.85 Deep blue CODE 664-089C Cedar 100x 1.25...
Page 7
WESTLAB 4. PARAMETER/TECHNICAL TERMS EXTREME 4-5 TECHNICAL TERMS MONOCULAR MICROSCOPE, (1) Total magnification=(magnification of objective) X (magnification of eyepiece) RECHARGEABLE, (2) Field of view=(line field of view of the eyepiece selected) ÷(magnification of the objective selected) (3) N.A.=n·sinα (max), N.A.is very important parameter which USER MANUAL marks the features of the objective and condenser.
WESTLAB 5. TROUBLESHOOTING EXTREME MONOCULAR Remedy Symptom Cause MICROSCOPE, Optics RECHARGEABLE, The nosepiece is not in the right Turn the nosepiece (1)The side of position into the right position the field of view is dark or Stain or dust has accumulated on the...
Tighten it slide smoothly fixed properly ORDERING WITH Electrics No power supply Check the connection WESTLAB IS EASY... of the power cable (1)The bulb The bulb is not inserted correctly Tighten it does not work ONLINE The bulb burnt out Replace it www.westlab.com...