  • Page 2: Table Of Contents

    Personal radiation detector Radiacode-10X series. User manual. Contents Chapter I Introduction 1 Appointment of the device ........................... 2 2 Device design ........................... 3 3 Technical specifications ........................... 4 4 Developer contacts ........................... 5 Chapter II Safety precautions and warnings Chapter III Stand-alone use of the device 1 Before use ...........................
  • Page 3 Chapter...
  • Page 4: Chapter I Introduction

    Introduction Introduction This section contains the general information about dosimeter Radiacode-10X series. Later in the document, the dosimeter Radiacode-10X series is also referred to as "device" and "dosimeter". Appointment of the device Radiacode-10X series Portable dosimeter personal radiation detector Radiacode-10X series is designed to assess the radiation situation in real time.
  • Page 5: Device Design

    · Sound, light and vibration alarms on the device, and the ability to duplicate them on a smartphone. Radiacode-10X series is a highly sophisticated and sensitive instrument. Please read the instructions to obtain reliable results. Device design...
  • Page 6: Technical Specifications

    500 mA Wireless connection BLE (Bluetooth 4.0 and higher) Display Monochrome graphic LCD, 128x48 pixels, 34x13 mm, FSTN, Transflective, Positive Dimensions, W*H*D 123x34x18 mm Weight 65 g Dust and moisture protection, code IP64 Requirements for © 2023 Radiacode Ltd.
  • Page 7: Developer Contacts

    The device works with iPhone and iPad devices with minimum system requirements: iOS operating system 17.0 or higher, or macOS 14.0 or newer and MAC with Apple chips. Developer contacts Radiacode Ltd. 3 Thalia Street, Office 222, Limassol 3011, Cyprus ел. +357 96 207695 E-mail: support@radiacode.com Web:https://radiacode.com © 2023 Radiacode Ltd.
  • Page 8 Chapter...
  • Page 9: Chapter Ii Safety Precautions And Warnings

    Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications made to this device not expressly approved by Radiacode LTD may void the FCC authorization to operate this device.Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
  • Page 10 Safety precautions and warnings RF exposure statement: This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The device is installed and operated without restriction. © 2023 Radiacode Ltd.
  • Page 11 Chapter...
  • Page 12: Chapter Iii Stand-Alone Use Of The Device

    Radiacode. The program is available for download at https://space.radiacode.com. With the help of the program Radiacode you can transfer data to a computer, view it and manage it personal radiation detectorом. For a detailed description of the program interface, see in chapter "Working with the use of a...
  • Page 13: Buttons

    · update firmware of the device. Buttons Personal radiation detector Radiacode-10X series has an intuitive menu system and is controlled by three buttons. Sound and vibration indication are also helpful in operating the instrument. The device is...
  • Page 14: Turning On And Off

    Pressing any button is accompanied by a short sound and vibration, depending on the settings. *The sound and vibration accompanying button presses can be turned off. Turning on and off To include Radiacode-10X series click on round button and hold it down for three seconds.
  • Page 15: Icons

    Various icons are used to label fields on the instrument status panel. At least 60% charge. At least 30% charge. At least 10% charge. Less than 10% charge, the battery needs to be recharged. The battery is being charged. Charge completed, external power supply. © 2023 Radiacode Ltd.
  • Page 16: Indication: Sound, Vibration, Light

    About device Information about the dosimeter serial number and software version. Indication: sound, vibration, light In personal radiation detectorе Radiacode-10X series sound and vibration sources are built in to acknowledge button presses and to indicate events and alarms. A light indication is provided for remote...
  • Page 17: Battery Charging

    To update the firmware take the following steps: · download the latest version of Radiacode software at https://space.radiacode.com; · install Radiacode on your computer and run it; · connect the device directly to your computer's USB port using the USB cable type-C (supplied with the device);...
  • Page 18: Menu Usage

    Stand-alone use of the device · install the latest version of the Android application in the application store: Radiacode or download from the link: https://space.radiacode.com; If the device bootloader is version 4.0 or higher - it is possible to update the firmware via Bluetooth: launch the application;...
  • Page 19: Device Settings

    Next, short presses on the up/down buttons of the swings can be used to move the focus to the desired item and make the required settings. This and deeper menu levels can be exited via [< Back] and [<< Menu quit]. © 2023 Radiacode Ltd.
  • Page 20: Selecting Units Of Measurement

    To return to the previous level or exit the menu, briefly press the up/down swing buttons to move the focus to [< Back] or [<< Menu quit]; · Briefly press the round button to confirm your selection; © 2023 Radiacode Ltd.
  • Page 21: Count Rate - Alarm Levels

    To return to the previous level or exit the menu, briefly press the up/down swing buttons to move the focus to [< Back] or [<< Menu quit]; · Briefly press the round button to confirm your selection; © 2023 Radiacode Ltd.
  • Page 22: Dose Rate - Alarm Levels

    Short presses on the up/down swing buttons to change the value of the selected digit; · Set all digits; · Short presses on the round button to select [Enter] or [Esc]; · Long press the round button to confirm your selection; © 2023 Radiacode Ltd.
  • Page 23: Dose - Alarm Levels

    [Alarm 2]; · Short press the round button to select the desired digit of the threshold value; · Short presses on the up/down swing buttons to change the value of the selected digit; · Set all digits. © 2023 Radiacode Ltd.
  • Page 24: Display Settings

    Briefly press the up/down swing buttons to move the focus to [Duration]; · Short press the round button to select the delay until the screen backlight turns off automatically: 5, 10, 15, 30 sec. and 2, 5 min; © 2023 Radiacode Ltd.
  • Page 25: Signals - Sound, Vibration, Light

    [< Back] or [<< Menu quit]; · Briefly press the round button to confirm your selection. 3.10.6 Signals - sound, vibration, light Personal radiation detector Radiacode-10X series is equipped with a combined interface for user interaction: · display; ·...
  • Page 26 Short presses on the round button to select the sound signaling mode: [On] - all allowed sounds; [Off] - only the sounds of searching for the instrument and going out of the measuring scale remain, if it is allowed by the settings. © 2023 Radiacode Ltd.
  • Page 27 Short press the up/down swing buttons to move the focus to [Power]; · Short press the round button to select [On] or [Off]. · To set the alarms, move the focus to [Alarms]; · Press the round button briefly to confirm your selection. © 2023 Radiacode Ltd.
  • Page 28: Bluetooth Settings

    Briefly press the round button to confirm your selection. 3.10.7 Bluetooth settings · Short press the up/down swing buttons to move the focus to [Bluetooth]; · Short press the round button to select the Bluetooth wireless communication mode: [On] or [Off]; © 2023 Radiacode Ltd.
  • Page 29: Language Selection

    Briefly press the round button to confirm your selection. 3.10.9 Time settings When connecting Radiacode-10X series The time on the device will be set automatically when you connect it to your smartphone or computer. Time setting is also available from the local menu of the device: ·...
  • Page 30: Reset To Factory Settings

    To return to the previous level or exit the menu, briefly press the up/down swing buttons to move the focus to [< Back] or [<< Menu quit]; · Briefly press the round button to confirm your selection. © 2023 Radiacode Ltd.
  • Page 31: Display Modes

    Stand-alone use of the device 3.11 Display Modes The RadiaCode-101 dosimeter has a single mode of operation - continuous data collection, accumulation and analysis. At any moment one of several ways of displaying the radiation situation assessment is available: –...
  • Page 32: Monitor

    - Sv/h, R/h, or count rate - CPS, CPM. With the help of the menu the choice between the measurement units is available: o Sv/h or R/h - when displaying dose rate; o CPS or CPM - when displaying the count rate. © 2023 Radiacode Ltd.
  • Page 33: Dose

    In the Dose display mode the screen shows: · status panel - from the top; · parameters of accumulated dose estimation. The upper part of the screen, from left to right, contains basic information about the status of the instrument: © 2023 Radiacode Ltd.
  • Page 34: Search

    In the Search display mode the screen shows: · status bar - on top; · search graph of count rate - at the bottom. The upper part of the screen, from left to right, contains basic information about the status of the instrument: © 2023 Radiacode Ltd.
  • Page 35: Device Info

    · Bootloader version; o FCC ID. *Not specified for all devices 3.12 Alarms The sources of alarms in the Radiacode-10X series device are: current value of count rate value; current value of dose rate value; value of accumulated dose; © 2023 Radiacode Ltd.
  • Page 36 Stand-alone use of the device There are three alarm thresholds for each of these sources in the Radiacode-10X series instrument: If the current count rate, dose rate, or dose value crosses any of the thresholds from bottom to top, an Alarm event occurs: ·...
  • Page 37 Alarm 2 on Dose. Alarm 3 on Dose over scale Light signals can be turned on/off in the settings Radiacode-10X series If the device has been locked, if the alarm indication settings (sound and/or vibro) are enabled, a line of...
  • Page 38 Chapter...
  • Page 39: Chapter Iv Working With A Smartphone

    Working with a smartphone Working with a smartphone To pair with your smartphone, install the app on your smartphone Radiacode, available at link: https://space.radiacode.com and GooglePlay, or use the QR-code: A detailed description of the application interface is included with the application and is available after installation.
  • Page 40 Chapter...
  • Page 41: Chapter V Work With A Pc

    The program is available for downloading at: https://space.radiacode.com. With the help of the program Radiacode you can transfer the data to a computer, view it, and manage personal radiation detector. A detailed description of the program interface is included with the program and is available after installation.
  • Page 42: Index

    Personal radiation detector Radiacode-10X series. User manual. menu usage Index menu use Alarm Battery charging pressing 11, 16 Before use Bluetooth button 11, 16 Reset resolution contrast control Count rate alarm screen screen adjustment screen contrast screen orientation date screen rotation...

This manual is also suitable for: