Instantaneous Water Moat err.
This mode! is suitablo for use wifh somo makos of instantaneous gas wator-hootors. i
nil details of
compatible water-heaters should be obtained from the healer manufacturer or Gas showroom
The use of these heaters may require more frequent cleaning of the Autowasher water inlet filters than
would be necessary with other water heating methods.
DRAINAGE
Length of drain hose
1.2 m
4ft
Standpipe bore (B)
38-40 mm
1 '/?in
Standpipe to floor (SH)
-maximum
1 m
40 in
- minimum
0.6 m
' 24 in
Preferred minimum standpipe (S)
380 mm
15 in
Suggested trap*
Bottle type
Bottle type
Fall to drain (F)
100 mm/m
1 in/ft
CONNECTING THE HRAINAGE
important
Before using your
machine
for
the first time ensure that the drain screen is fitted correctly. Failure to
do so
may
result
in a
flood.
A standpipe is recommended, with the dimensions shown.
The hose can be hooked over the edge of a sink.
Permanent drainage arrangements should conform to the dimensions given. There must be an airbreak
or the appliance may syphon.
The drain pipe should not be pushed into the standpipe more than 200 mm (8 in).
The dimensions given In these instructions are not intended to be direct conversions between metric
and Imperial units. Please work in one set only.
'The recommendations set out are suggestions only. Alt installations must comply with the requirements
of local authorities or public utilities.
This appliance complies with European Economic Community Radio Interference Direclive 02'499 EEC
OPTIONAL EXTRAS
Optional fittings are available from your Bendix stockist and will ease the installation and use of the
appliance:
Stopcocks:
'Hot'
24041
'Cold'
24042
Cold-fill F connector
25115
Stacking Kits:
with pull-out shelf
28300
without shelf
28301
For use with model 74568
The dimensions given in these instructions are not intended to be direct conversions belween metric
and imperial units. Please work in one set only.
This appliance must be installed in accordance with the IEE regulations, in particular wifh regard to
installation In bathrooms; if not we reserve the right to refuse to service it.