BEFORE YOU BEGIN 1.1 PRODUCT DESCRIPTION This restoration dehumidifier remove moisture of room . which commonly used in basement, warehouse , villa and many so on The environmentally friendly R32 is used as the refrigerant. R32 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide.
Page 4
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
FOR YOUR SAFETY Please read this manual carefully and fully understand before operating your appliance. WARNING If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. ...
Page 6
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture. The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater). ...
Page 7
2.2.3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
Page 8
2.2.9 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
SPECIFICATIONS Model No. D-145 Power supply AC115V/60Hz 90Pints/Day@80℉,60%RH Dehumidify Capacity 180Pints/Day@95℉,90%RH Rated Input Current 6.5A@80℉,60%RH MAX.InputCurrent 9.5A RefrigerantCharge R32/13.23oz HighSide:550psig MaximumDesignPressure LowSide:260psig BCSC CompressorInput RLA:6.15ALRA:36A Fan Motor Power 0.75A/0.114HP FEATURE Compact design with large dehumidify performance fits where others don’t –like crawlspaces, bathrooms, kitchens, etc.
OPERATION Power Button:When the machine is in the standby mode, the display screen will be displayed in low light LED. To start the dehumidifier, press the power button. Concurrently, the display screen will light up and the unit will run in Auto mode ,the default humidity setting data is 10%RH,and the machine will start if the humidity condition meets the requirement of compressor operation.
Page 12
setting range is from 0 to 24 hours. If you set the timing data as “00”,it will cancel timing function ,the timing indicator will turn off Add Button: Press the Add button to increase humidity data or increase timing data . When setting the humidity data , press the button for one time to increase 5%RH , you can set the humidity range from 10%-90% RH, and 5% RH for one step , it will cycle as below :...
Page 13
hour , it will cycle as below: 24-23-22-21-20…-02-01-00-24-23… Purge Button (Manual Drainage): Press and hold the purge button for 3 seconds, the machine will drain the water automatically by the built-in pump. After 30 seconds, the pump stops draining, then the indicator will turn off. Defrosting Indicator: When the machine is defrosting, this indicator turns on.
Page 14
Memory Function: If there is a power outage or the unit shuts off ,it will auto restart to default humidity setting (10%RH) ,once power is restored . Note : when humidity of air inlet ≥ setting humidity data +3%RH ,and the compressor is out of 3 minutes delay start protection , the fan will start immediately and the compressor will start in 3 seconds later when humidity of air inlet ≤...
AUTO DRAINAGE &MAINTENANCE Please disconnect the power supply before cleaning or conducting maintenance. Auto Drainage: Connect water hose (≤13.12 ft length) to the water drainage hole by quick connector, the machine will automatically drain by water pump through water hose when operating Cleaning: Clean the unit body with a soft damp cloth.
Page 16
Error prompt and code running status 1. "E1" code: This code appears when the copper head sensor is damaged. The machine will keep running, but every 30 minutes , the compressor will stop for about 10 minutes, then continue to run . After that ,the machine will repeat the cycle like this.